  • Hello! I am an AI chatbot trained to assist you with the Sharp L20SDI3600UK Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Version 1.0 (English language)
Revision Date : 25
th
September 2015
Item Meter Information
Maker
Autometers
http://www. Autometers.co.uk
Tel : +44-161-861-9056
Model Name DDSD285
Interface RS485-Modbus
Direction Bi-directional
Need Qty. 1 ea
Energy Meter Install Guide for UK - Overview (1/3)
Version 1.0 (English language)
Revision Date : 25
th
September 2015
Energy Meter Install Guide for UK – Wiring Diagram(2/3)
L
N
Load
RS485 Communication Line
LoadLoad
Generation
Meter
GRID
AIO PV
Utility
Meter
Energy
meter
(DDSD285)
Meter (DDSD285) Grid/All-in-One Connection
(1) Live In L (Grid)
(3) Neutral In N (Grid)
(4) Neutral Out Load - N (All-in-One)
(6) Live Out Load - L (All-in-One)
(13, 15) No Use -
(20, 21) No Use -
(23) TX + RS485-A (All-in-One)
(24) TX - RS485-B (All-in-One)
Version 1.0 (English language)
Revision Date : 25
th
September 2015
Energy Meter Install Guide for UK - Setting (3/3)
(DDSD285 Meter Setting)
In case of DDSD285, it is NOT necessary to change the configuration at all.
(All-in-One Setting)
1. Meter Type : “D0 (Bi-Direction)”
2. D0-Bi/Feed-In : “10:C2000(Autometers)”
DDSD285 is compatible with C2000.
3. Modbus Address : “1”
Because the Modbus address of DDSD285 is set to “1” in factory, it is NOT allowed to change.
1. Meter Type
2. D0-Bi/Feed-In
3. Modbus Address
Version 1.0 (English language)
Revision Date : 25
th
September 2015
Annex. Detailed Wire Diagram
MAINS(GRID)
LOAD
L
N
RS-485
(TX+)
23
6431
TX+
TX-
N L
(TX-)
24
/