Ensy AHU-200 KH SLIM, AHU-200 KV SLIM User Manual And Installation Manual

  • Hello! I am an AI chatbot trained to assist you with the Ensy AHU-200 KH SLIM User Manual And Installation Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
User manual and
Installation Guide
AHU-200 KV SLIM
AHU-200 KH SLIM
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side1
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side2
Usermanual.Pages2til15
(Onpages,2‐6thepicturesshowsAHU200KVSLIM)
Becarefulthatthedoorcan"bestuck"inthesealingonthehatch.
Foreasierlooseningofthehatch,releaseitfirstinonecorneratthetop.
Tooperatethisproductpeopleshouldhave
necessaryskills,orunderthesupervision
ofaqualifiedperson.
Tellchildrennottoplaywiththeappliance.
Ifyouaregoingintotheunitthenyoufirsthavetoremove
anykitchenfurniturefrontdoor,ifsoismountedonfront
ofunit.
Onthesepictures,youcan
seetheventilationunitwith
whitecoatedcookerhood.
Therearealsovariantswithhoodsinbrushedstainless
steel.
Toopenthefronthatchyoufirsthavetountightenthose
fourscrewsyoufindineachcorneroftheunit.
Whenhatchis
tobemountedbackontheunittrytousealmostsametorqueonallfourscrews.
Thenputthekitchenfurniturefrontdoorbackonplace.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side3
Beforeanyaccessintotheelectrical
connectionsboxes,power
mustbedisconnectedby
pullingouttheplugfromthe
socket.
Onlyauthorizedpersonsisallowedtoenter
intotheelectricalconnectionboxes.
Ifanyelectricalcomponentsaredamaged,
theymustbereplacedbythemanufacturer,
dealeroraqualifiedpersonin
ordertoavoid
dangeroussituations.
Adjustmentoftheunit.
Ahumiditysensoris,fromfactory,mountedinsidetheunit.Itis
setto“0”thatmeansitissettonotactive.
Afterstartup,wheretheunitisplacedintoanewbuildingwithhighhumidity,
youcanletthishumiditysensorbeturnedoffforaperiodto
avoidthefullspeed
ofthefanatnight.Togetthehumiditysensortooperateasintended,youneedatonetimetoputit
active.Thanyouneedtosettheswitchinposition"1".
Iftheventilationunitisplacedinahousewithouthighhumidity,you
shouldswitchtoposition"1"
afteryouputtingventilationunitintooperation.Thisswitchwillalsoaffectanyextraexternal
humiditysensorthatispluggedintothedevice.
Adjustingthehumiditysensor.
Ifitisnecessarytoadjustthesensitivityofthehumiditysensorthenyoujustcanremovetheblack
plugandyouthencanseetheadjustingknobandtheRH%scale.
Ifaneedforbetter
insightordonotsee
theadjustmentscale
sufficientsoone
shouldremove
the
entirecoverofthis
controlboard.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side4
Thesensorissetto80%RHfromfactory.
Ifyoudoadjustments,thisonlyaffectthesensorintegated
insidetheunit.
Thesensitivityfortheintegratedsensoryoucanadjustfrom
50%(low)to90%(high)inaccordancetowhataretheneed.
Thearrowpointsthevaluechosen.
Ifyouhaveasecondexternalsensorthatmeansyouneedto
adjustthatonefromitssettings.
Replacethecoverand/orplugafterfinishadjusting.
Replacingthefilter.
Thefiltersshouldbereplacedevery6.9.
or12.months.
Shouldbeextractedwithoutuseofany
tools.
Remembertoenterthecontrolpanel
menu(4.3Filter)andpressFilterOK
afterthefiltershasbeenreplaced.
Toguaranteeoptimalpropertiesofthe
ventilationunit,usetheoriginalfilters
fromEnSy.Theuseofspuriousfilterswill
limitthewarrantyontheproduct.
Ensyartnumberforfiltersetis:
0114608502
SETFILTREENSYAHU200+300B.F7:120x280x94
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side5
Cleaningthefans.
Thismustbedonebyaqualified
person.
Beforeremovingfansthemainpower
mustbedisconnectedbypullingout
themainsupplyplugfromthesocket,
orfanstobeprogrammedtoposition
AVorOFF
Disconnectthe3poleand5pole
plugs.
Thefanscanbe
pulledoutofthe
ventilationunitwithouttheneedfor
anytools.
Cleanwithmildsoapandwater
Maintenanceandcleaningof
rotaryheatexchanger
.
Thismustbedonebyaqualified
person.
Disconnectthe3poleplug.
Canbepulledoutoftheventilation
unitwithouttheneedforanytools.
Tonotscratchthecookerhoodsoyou
shouldcoverthisbeforeyoupullout
therotaryheatexchanger.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side6
Rotorexchangercaneasilybe
removedforcleaningbydissolving
the12screwsthatholdit
together.
Cleanpartswithmildsoapand
water
Donotexposethe
rotormotoror
connectorfor
moisture.
Theexchangeryoualsocancleanwithmildsoapandwater.Donotuseammonia
containingdetergent,asthiswillpreyonanddiscoloraluminuminrotaryheatexchanger.
Flushedwithhandshowerandblowgentlycleanwithcompressedair.
Ensurethatthescrewsaretightenedsufficientlysothattheydonotcomelooseduringoperation.
Preferablyuseascrewdrivertotightthescrews.If
useofelectricalscrewdriver,makesurethatyou
uselowtorquetopreventdestroyingthethreadsinthesheetmetalparts.
Tomakesurethatthedrivebeltcanadjustitselfintocorrectpositionyoumustrotatetheexchanger
somefewturns.
Theninsertbackintotheventilationunit.Besure
thatrotorexchangerisproperlyinsertedinallthe
guidesinsidetheunit.Ifnot,thiscanleadtovibrationinthesystemandinternalairleakintheunit.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side7
Operation of kitchen hood
ON/OFFswitchfordownlights.
Usingthedamperinakitchenhood.

Nofunction Opensdamper. Maxtimeontimer
Timeractivated 60min
Replacingthelampandtransformeronthecookerhood
Turnoffthepowerbefore
replacingthedownlight.
Ifthelightisnotworkingthenyou
mustreplacetheentirelight
socketandtransformer.To
replacetheusermustfirstremove
thefourblankingplugsandthen
loosenfourscrewstoreleasethe
entirecover.
Compressthespringwithfingers
tomoreeasilyslidinglightsocket
outthrough
cover.
Theplugsthatisbetweenlight
andtransformercanbepulled
apart.
Theswitchhasa
springretraction
andwillnotwork
untilithaspassed
"Min"
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side8
Iffaultylightthenbothdownlightandtransformerreplacedwithnewparts.
OriginalLEDlightthatisinsertedfromfactory
Ensyartno:
2604552DownLightLED5Wwithwhitesocket
andtransformer
2604562DownlightLED5Wwithblacksocketand
transformer
Replacementorwashingthefilterinthekitchenhood.
Releasefromtheframebypushingthelocktothe
middleofthefilterandtilteddown.Thefiltercanbe
washedinsoapywater.Mustbecompletelydrybefore
itismountedinplaceagain.Ifthefiltermaterialis
damageditmustbeorderedneworiginal.
(Ensyart
no:2700812)
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side9
Mainmenu
1.ControlButtonindicatorforfan.
2.ControlButtonindicatorsetpoint.
3.ControlButtonindicatorinformation.
4.ControlButtonindicatorsettings.
Overviewofcontrolpanel
Themainscreenconsistsof,fromtop,left:
TimeIndication,hour,minute
Timer,Weeklyschedule(ifprogrammed)
Reheatingcoil(ifconnected)
Temperaturereadings,Outdoor/Indoor
Statusairflowfanspeedsetting
OFFMINNORMorMAX
Temperaturesetpoint,15‐21°C
Reheatingcoil(hererefersactiveelement)
RotaryexchangerIndicator‐(hererefers
activerotarywheel)
Indicatorsinthemenuscreen:
"Sun"indicatesthattherotorhas
stopped,theairhandlingunitisin
thesummeroperationmode.
"Snowflake"lowtemperature
indicatesthattheairhandlingunit
isindefrostingmode.
"Steamingpot"andblinkingfan
bladesindicatesthatthekitchen
exhaustisactivated.
"Timer"andthecountdownofthe
fansymbolindicatethattheforced
ventilationisenabled.
From10upto240minutes
"Away"indicateswhen
thefeature
isenabled,thisfeaturewilloverride
timer.
"Clockoverthefansymbol"
indicatesthatthetimerisactivated.
Co2overthefansymbol"indicates
thatthecarbonsensorisactivated.
"Exclamationpoint"indicatesthat
moisturerecordedoverthesensor
ishigherthanthesetvalue.
Mayalsoindicatethatthemotion
sensorisactivatedifconnectedon
D2signaloutput.
Thissymbolindicatesthatthe
rotaryheatexchangerisactivated
andwillberotated.
ControlButton1. 2. 3. 4.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side10
1.Fanspeed
Ventilationunithasthreeoptionsforchoiceof
airflow.
Min,NormalandMax.
Forprogrammingofvalueswithineachstep,
see4.5.1.3Usingthecontrolbutton1,and‐/
+buttonscanchangebetweenthepre
programmedselections.
1.1Fanboost
Forcedventilation,fanspeedincreasestomax
speed.(Meanstothespeedthatissetin
menu4.5.1.3.)Thefunctionisforuseifhigh
humidityinbathroomsandlaundryroom.
Forcedventilationcanbeactivatedwith
button
then
Intervaladjustablefrom10‐240minwith+
and
Thispictureshows10minforcingtime,but
notactivated.
Toactivatethefanboostuse
controlbutton4.
YoucanseethatthefanarerunningwithMax
speedandtheclockwillstartcountdown.
Youcaneasydeactivatethefanboostagain
beforethecountdownautomaticallystopsit.
Firstcontrolbuttom1
andthen4.
Thisfeaturecanalsobeoperatedwithan
externalpulseswitch.Theswitchisplacedin
thebathroomoradjacentrooms.Connected
tocontactD1intopoftheventilationunit.
(Lookatpage23inthismanual.)
IfthisoptionviaD1isintendedforuseagainst
woodstoveor
fireplacethenitis
recommendedthatMaxspeedunderFan
controlinmenu4.5.1.3.issettoSupply100%
andadjustExtracttobe80to85%.(Lookat
page10inthismanual)
2.Temperature
Choosefrompreprogrammedtemperature
settingssetpointbetween15‐21°C.Setting
ischangedbyoperatingtheswitchbuttons
below‐/+symbols.
HeatingelementcanherebesetONorOFF
byoperatingtheswitchbutton4inthis
screen,butonlyifheaterisconnected.
(Toseeifheatingcoilisconnectedor
disconnected,see4.5.1.1Heater)
Indicatorforactivatedheatingcoil.
Smallpictureshownotactivated.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side11
3.Information.
3.Information/3.1.Alarms
Whenalarmyoucanfindasourceoferror
here,aswellasinfoonhowthealarmisreset.
(Seepages29and30inthismanual)
3.Information/3.2Programversion
Informationaboutthesoftware
version.Thisinformationmustbeprovidedto
servicepersonnelatthefailureoftheunit.
3.Information/3.3.Generalinfo
Hereyoucanseedefrostmodethathas
beenchosen.
(See4.5.1.9ifyouwanttochangemode.)
4.Preferences
Tonavigatewithinthevarioussubmenus
whenusingthecontrolbuttonsbelowtheup/
downcursorkeythatdisplaysonthedisplay.
4.Preferences/4.1Time/date
SettingmenuforTime/date.Thissettingis
importantsincetheinformationformingthe
basisfortheweeklyschedulefunctionifthisis
tobeactivated.Alsoforthefilteralarm
functionitisneeded.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side12
4.Preferences/4.2Weeklyschedule
ProgrammingoftheWeeklyschedule,fan
speedandtemperaturesetpoint.Hereitcan
beprogrammedfortwoperiodseachday.Ex.
day‐night.
Everydaymustbeprogrammedindividually.
Monday‐aperiodoftime,selectthestart
time.Toactivatetheperiod,X‐overperiod
numberisremoved,usethe/+keys.
Useentertomovebetweenthedifferent
fields.
Chooseairflow(fanspeed)Speeddialing‐
MINwhenonefanbladeontheindicatoris
black.NORM=twoblackfanbladesonthe
indicator.MAXspeed=threeblackfanblades
ontheindicator.
Selectthedesiredsupplyairtemperatureyou
wantduringtheperiod.Settingsbetween15‐
21°C.
Ifweeklyschedulelookssomethinglike
thiswithoutanyreasonthenyoumust
punchinallthedataagain.
Itdonothelptoupdatesoftware.
4.Preferences/4.3Filter
Settingthetimeintervalforfilterchange,
currentchoicesare6,9or12months.Make
yourchoicesbyusingthecursorkeys+/.
Alarmresetelapsedperiodbypressingthe
menubutton4,under"FilterOK"
4.Preferences/4.4AdjustScreen
Adjustingthecontrastandcoloronthe
display.
Youcanalsoadjusthowlongitshouldbelight
inthedisplayaftertheoperation.
4.Preferences/4.5Setup
Toproceed,usePINcode1000
Press
+oncetillitshows1000in
display.Thenpress4timeson
Thenpressbutton3forOK4.5.1
Starttime Stoptime
Fanspeed
Activationoftheperiod.Herenotactive
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side13
4.5.1Setup
4.5.1.1Heater
Turningon/offthereheatingcoil,usethe
minusorplusbuttontochangesettings.
4.5.1.2Coolingrecovery
Activationofthecoolingrecovery:
Itispreprogrammedtwooptionsforuse
whentheoutsidetemperatureishigherthan
theindoortemperature,heatrecoverysystem
willactivatethefunctionstartandsupplyair
willbecooledbyexhaustair.Engagement
whentheoutdoortemperatureis2°Cor3°C
higherthanroomtemperature.Use
button4
tochangesettingforOff.Press+toactivate
(On).Usebutton4tochangesettingfor2°C.
Press+tochangetoto3°C,ifwanted.
4.5.1.3Fancontrol
FactorysettingsforAHU200KVandKHSLIM
youcanseeinnextpicture.
Theinstallercanadjustthesesettingssothat
itisadequatelybalancedventilation.
4.5.1.4Co2control
IftheunitshallbeconnectedCO²controlthen
connectittoC0²connectorontopoftheunit.
(Seepage24inthismanual).
Menuforenabling/disablingofCO²control.
ScrolltoOffandpress+toactivate.On
Hereyoupreprogrammedwantedppmvalue
andtheboostspeedforthefans.
Note:Togetbalancedventilationisa
prerequisitethatSupplyandExtractairfan
hasthesamevalueastheMAXvalueunder
4.5.1.3
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side14
4.5.1.5Cookerhood
Menuforprogrammingoffanspeedsby
activationofthekitchenhood.
SupplyandExtractairshouldhavethesame
valueastheMAXvalueunder4.5.1.3(Setto
100%fromfactory.)
4.5.1.6Externalarm
Iftheunithasbeenconnectedtoanexternal
humiditysensorormotionsensor.UsetheD2
connectorontopoftheunit.(Seepage24in
thismanual).
Note!Inorderforthisfeaturetowork,you
needtheonepoleswitchmarkedRH%ON/
OFFinsidethe
unittobesetinposition1.(See
page3inthismanualforthelocationofthis
switch).
SupplyandExtractairshouldhavethesame
valueastheMAXvalueunder4.5.1.3(Setto
100%fromfactory.)
4.5.1.7Absent
Menuforsettingthedesiredvaluesby
activatingaway/homefunction.
UsetheD3connectorontopoftheunit.(See
page24inthismanual)Functionisoperated
viaanexternalswitch.
Setvalueofthedesiredtemperaturewill
showinthedisplayafteractivatingthe
function.
4.5.1.8Calibration
Menureadingofembeddedtemperature
sensors.
Thesetemperaturesensorsare
deliveredcalibratedfromthe
manufacturerandshouldnotbeattempted
changeinhere.
The«Outsideair»sensornormally
shows36°Chightertemperaature
thenthereeloutsidetemperature.Thisisdue
toheatingoftheairintheductnetworkfrom
theintakegrilleto
theintakeoftheunit
wherethesensorareplaced.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side15
4.5.1.9Defrost
Menuforhowtochangedefrostmodeif
temperatureislowandhumidityisheight.
Fromthestartupmenuyoucanseewhich
defrostmodetheunitissetin.
TheunitissetinmodeOFFfromfactory.
Ifitisneededtochangethedefrost
modetoanothermodethenpress
button4andscrolldowntoConfiguration
withbutton3.
Pressenterbuttonandfollowprocedure
asinMenu4.5Setuptocontinue.
Pressenterbutton
DefrostmodeOFFfromfactory.
Modus1:atlowhumidity.
Defrostingfunctionstartat‐20°C.
Modus2:atnormalhumidity.
Defrostingfunctionstartat‐15°C.
Modus3:athighhumidity.
Defrostingfunctionstartat‐10°C.
Thefunctionwhendefrostingstartsisthat
eachhourthesupplyairfanstopsfor6
minutes.TheheaterEVturnsoff.Extractair
fanreducesspeedto30%andtherotary
exchangerwillrunasnormal.
Toavoidthattherotaryexchangerwillstop
whenthecyclegoesbacktonormalfunction,
thesupplyairfanwillstartupthelastminute
ofthedefrostingmodecycle.
(Supplyairfanreactsdelayedrelativetothe
controlsignalsandrotaryexchangersothat
theheaterwillnotengage untilthespeedof
thesupplyairfanhaspassed250r/min,in
normaloperation).
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side16
4.5.1.10Displaynumber
Onthisunititisonlypossibletoconnectone
display.
Fromthismenuithastobespecifiedthatthe
controlpanelsis«Display
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side17
Mountinginstructions.Pages17to28.
TableofContents
1.General
2.Mountingoftheunit
2.1Bracketsandgasketstoavoidvibration
2.3Ductcover
2.4Dimensionsandtechnicaldata
3.Connections
3.1Electricalconnections
3.2Ductconnections
4.Settingtheairflow
5.Alarms
1.General
Thisguideismadetoprovideinstallationanduserinstructionsregardingthecorrectinstallationof
AHU200KVSLIMandAHU200KHSLIM.
AHU200KVandKHSLIMisdesignedforheatrecoverywithairvolumesofupto200/h.The
energy
fromtheexhaustairistransferredtosupplyairthroughtherotaryheatexchangerwherethe
airstreamspasseachotherwithoutmakingcontact.
Theunithasabuiltinheaterforsupplementaryheatingofsupplyair.Humiditysensorforforced
ventilationisintegratedintoventilationunit
Theunitcan
alsoconnectadditionalequipment.Pulseswitchforcontrollingtheforcedventilation,for
example,wetroomsorbathrooms,sensorforcarbonmanagementandswitchmanagementaway/
homefunction.ControloftheseoptionsareintegratedintoAHU200KVandKH.
AHU200KVandKHSLIMissuppliedinpaintedfinish,testedandreadyforoperation.Installation,
commissioningandtuningmustbeperformedbyauthorizedpersonnelTherearealsovariantswith
hoodsinbrushedstainlesssteel.
2.Mounting
Togetherwiththeunitisdeliveredthefollowingequipment:
1.Suspensionbracketandstoppers
2.WallBracketwithvibrationdampeninggasket
3.Selfadhesivevibrationdamping
4.Accessoriesbagcontainingthenecessaryscrews
5.4pcs.plugsforconnectingadditionalequipment.
6.Partsformountingkitchenfurniturefrontdoor.
7.Controlpanel
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side18
First,selecthowtheunitshouldbemountedsothatthepipingsystemshouldbeaseasyaspossible.
(SketchovershowsAHU200KVSLIM)
(SketchovershowsAHU200KHSLIM)
Freshair.
Supplyair.
Extractair.
Exhaustair.
Freshair.
Supplyair
Extractair.
Exhaustair.
3938292Rev1:19.04.2017.KJK
Wereservetherighttochangetechnicaldatawithoutnotice.http://www.ensy.no Side19
2.1Bracketsandvibrationgasket
Suspensionbracketscrewedontopofthe
unitasshown.
Use8pcsM5x16mm,suppliedwiththeunit.
(SketchovershowAHU200KVSLIM)
Mountthewallbracketwithvibrationgasket.
Makesurethattheedgeprotectiongasketisplaced
onthe
wallbracket.
Besurethatthevibrationgasketisintact.
Gluevibrationgaskettothebackofthe
unit,seeillustration.Approx.50mm
fromthebottomoftheunit.
Lifttheunitinplaceandensurethat
thereisnodirectcontactbetweenunit
andbuildingconstruction.
/