Mounting Instructions
Decentralized Ventilation System with Heat Recovery Type
e² mini
- Please pass on to User-
Contents Page:
About these instructions, Safety instructions, Technical data, Disposal 1
Dimension drawings, Mounting position 2
Scope of application, Shipping units 3
Assembly: Mounting tube, Outer grille 4
Assembly: Electrical installation and Electrical connection 5
Assembly: Heat exchanger unit and interior screen 6
Filter change, Cleaning, Additional and Spare parts 7
About these Instructions
Read these instructions carefully and completely before executing assembly work! General safety
instructions and the safety symbols with respective notes in text form must be observed.
These instructions are to be passed on to the user after completing assembly work (tenant, own-
er, building administration etc.).
Symbols in these instructions
This symbol warns of a risk of injury.
This symbol warns of a risk of injury from electricity
Safety Instructions
Caution! All terminals must be completely disconnected from the power supply before com-
mencing assembly work! The fan is insulated pursuant to Protection Class II, connection pro-
tection does not apply!
Attention! Electrical connections must be carried out by authorized qualified staff in accord-
ance with applicable VDE 0100!
Attention! This device must not be operated by children or persons (filter change/cleaning)
who are not able to operate it safely on account of their physical, sensory or mental capacity or
due to their inexperience or lack of skills. Children must be supervised to ensure they do not
play with the device.
Technical Data
Supply voltage: 230 VAC 50 Hz
Device voltage: 12 VDC SELV
Protection Class: IP 22
Flow rate: 5m³/h; 10m³/h; 20m³/h
Disposal
Dispose of packaging correctly sorted. If you wish to dispose of the device, observe applica-
ble conditions. Your local disposal center will provide relevant information.
1