Pluggit iconvent Operating instructions

Type
Operating instructions
www.pluggit.com
Operating and installation instructions
Pluggit iconVent
Decentralized residential ventilation with heat recovery
The technology makes the difference.
Innovations of Pluggit with an added value for the human being and environment.
The 2Q-ventilation typical for PLUGGIT room systems guarantees efficiency and
comfort for the distribution of supply air. The first Q - the displacement ventilation -
distributes the fresh air very slowly without any background noises and draughts in
the room. The second Q - the cross ventilation - causes a complete air flow of the
room. In this, the fresh air outlet in the outside wall area is positioned as far away as
possible from the door of the supply air room.
The special PLUGGIT iQoanda-air outlet is positioned above the access of the supply
air room, if possible. The Qoanda effect leads the air flow along the ceiling in the
furthest corner of the room. By means of this type of flow a comprehensive air quality
is ensured without any background noises and draughts.
The distribution systems of PLUGGIT allow an installation of pipe systems at all three
installation levels. For new buildings or renovation the ventilation ducts can be
assembled safely and easily: in the insulating layer of the floor, in the bare concrete
of the ceiling or below the ceiling.
The innovative and unique PLUGGIT ServoFlow-technology guarantees the supply of
utilization-oriented air volume for a building at any time. Above all, it ensures the
important balance of supply and exhaust air flows by means of an automatically
conducted calibration once a week and documents modifications, like the filter
contamination in the plant.
The energy efficiency of ventilation units is defined by two factors. The high heat
recovery of our ventilation units ensures low heat losses and comfortable supply air
temperatures. Decisive, however, is the power consumption. By means of highly
efficient direct current vans the operating costs are reduced to a minimum. Thus, the
ratio of heat recovery and power consumption, which means the efficiency, is the
most significant value and is defined as coefficient of performance. At the coefficients
of performance PLUGGIT ventilation units achieve maximum values of up to 26 and
thus guarantee an excellent energy efficiency.
CleanSafe stands for an easy cleaning. As a first company PLUGGIT had a cleaning
system certified which facilitates cost-effective cleaning and maintenance of all
system components, whether a round tube or a shallow duct distribution system is
installed.
Fresh air and heat supply in one system - faster, more flexible and more energy-
saving than common heating systems.
Perfect feel-good climate by means of optimal air humidity in the room air with the
air humidifier AeroFresh.
2Q
allfloor
ServoFlow
CleanSafe
1
BIA Single room ventilation unit iconVent Mono and iconVent Duo
1. General safety instructions ................................................................................................. 3
2. General notes ...................................................................................................................... 3
2.1. Appropriate use ................................................................................................................... 3
2.2. Non-appropriate use ........................................................................................................... 3
2.3. Warranty .............................................................................................................................. 3
3. Overview ............................................................................................................................. 4
3.1. Single-room ventilation unit iconVent Mono ...................................................................... 4
3.2. Single-room ventilation unit iconVent Duo ......................................................................... 5
4. Function/principle ............................................................................................................... 6
4.1. Single-room ventilation unit iconVent Duo ......................................................................... 6
4.2. Single-room ventilation unit iconVent Mono ...................................................................... 7
4.3. Cross ventilation .................................................................................................................. 8
4.4. Installation type single-room ventilation unit iconVent Duo .............................................. 9
4.5. Installation type single-room ventilation unit iconVent Mono and iconVent Duo ............ 10
4.6. Installation type single-room ventilation unit iconVent Duo and exhaust air van ........... 11
4.7. Installation type single-room ventilation unit iconVent Mono, iconVent Duo
and exhaust air van ........................................................................................................... 12
4.8. Regulation .......................................................................................................................... 13
4.8.1. Regulation schemes ................................................................................................ 14
4.9. Time-delay relay ................................................................................................................ 21
4.9.1. Connection diagram ................................................................................................ 21
4.9.2. Technical data .......................................................................................................... 21
4.9.3. Measurements ......................................................................................................... 21
5. Installation (qualified staff) ................................................................................................ 22
5.1. Notes for installation
......................................................................................................... 22
5.2. Assemble installation stone ICVS and installation sleeve ICVH
....................................... 23
5.2.1. Installation stone ICVS for single-room ventilation unit iconVent Mono ............... 23
5.2.2. Installation stone ICVS for single-room ventilation unit iconVent Duo .................. 23
5.2.3. Installation sleeve ICVH for single-room ventilation unit iconVent Mono ............. 24
5.2.4. Installation sleeve ICVH for single-room ventilation unit iconVent Duo ................ 24
5.3. Install single-room ventilation unit
.................................................................................. 25
5.4. Initial operation
................................................................................................................. 27
TABLE OF CONTENTS
2
BIA Single room ventilation unit iconVent Mono and iconVent Duo
5.5. Technical data .................................................................................................................... 28
5.5.1. Unit data ................................................................................................................... 28
5.5.2. Regulation ................................................................................................................ 28
5.5.3. Measurements ......................................................................................................... 28
5.5.4. Basic wiring diagram, electrical .............................................................................. 30
6. Operation (user) ................................................................................................................ 31
6.1. Overview regulation ........................................................................................................... 31
6.2. Increase/ reduce fan level ................................................................................................. 31
6.3. Reset filter alarm ............................................................................................................... 31
6.4. Error correction ................................................................................................................. 32
6.4.1. Disturbances ............................................................................................................ 32
7. Maintenance (user) ............................................................................................................ 33
7.1. Clean inside panel ............................................................................................................. 33
7.2. Clean ceramic heat exchanger .......................................................................................... 33
7.3. Clean/ change filter ........................................................................................................... 34
8. Decommissioning/disposal ................................................................................................ 35
8.1. Decommissioning at extension ......................................................................................... 35
8.2. Packaging ........................................................................................................................... 35
8.3. Old unit ............................................................................................................................... 35
3
BIA Single room ventilation unit iconVent Mono and iconVent Duo
2.1. APPROPRIATE USE
The decentralized single-room ventilation unit iconVent
Mono and iconVent Duo serve as regulated aeration and
ventilation of individual supply air rooms, for example, living
rooms and children's rooms as well as exhaust air rooms,
for example, kitchen and bathroom with window in accord-
ance with DIBt-approval.
2.2. NON-APPROPRIATE USE
Other uses of the decentralized single-room ventilation unit
than those described under "appropriate use" are inadmis-
sible.
The decentralized single-room ventilation unit shall not be
applied
for construction drying.
2.3. WARRANTY
For a full legal warranty claim the technical standards of
these operating and installation instructions shall be ob-
served.
1. GENERAL SAFETY INSTRUCTIONS
Warning:
The following safety instructions shall be noted, other-
wise injuries or damages can be implied:
z Before you begin with the installation and operation
of the decentralized single-room ventilation unit,
carefully read these operation and installation in-
structions.
z The installation and all electrical works shall only
be carried out by qualified staff.
z Consider all necessary legal and national standards
(accident prevention regulations and acknowl-
edged rules of technology) for the installation and
initial operation of t
he decentralized single-room
ventilation unit and observe them.
z Damages which occur due to product-inappropriate
storage, improper operation and installation or
non-appropriate use are excluded from each kind
of liability.
z Subject to technical changes.
2. GENERAL NOTES
4
BIA Single room ventilation unit iconVent Mono and iconVent Duo
3.1. SINGLE-ROOM VENTILATION UNIT
ICONVENT
MONO
1 Pluggit iconVent inside panel Mono ICVM-B
2 Base plate, inside
3 Plugg
it iconVent functional unit ICVF
4.1 Plugg
it iconVent installation stone ICVS
4.2 Plugg
it iconVent installation sleeve ICVH
5 Base plate, outsid
e
6 Ins
ulation mat
7 Plugg
it iconVent weather protection grid
Mono ICVM-WSG
3. OVERVIEW
unten
oben
oben
unten
1
2
5
6
7
4.1
4.2
3
M+P-26A-1204
Note:
Depending on the construction plan the Pluggit iconVent
installation sleeve ICVH (4.2) can also be used instead of
the Pluggit iconVent installation stone ICVS (4.1).
This is designed as round EPP sleeve 198
mm.
5
BIA Single room ventilation unit iconVent Mono and iconVent Duo
3.2. SINGLE-ROOM VENTILATION UNIT
ICONVENT DUO
1 Pluggit iconVent inside panel Duo ICVD-B
2 Base plate, insid
e
3 Pluggit iconVent
functional unit ICVF
4.1 Pluggit
iconVent installation stone ICVS
4.2 Pluggit
iconVent installation sleeve ICVH
5 Base plate, outside
6 Ins
ulation mat
7 Pluggit iconVent
weather protection grid
Duo ICVD-WSG
unten
oben
oben
unten
unten
oben
oben
unten
1
2
5
6
7
4.1
4.2
3
3
M+P-26A-1205
Note:
Depending on the construction plan the Pluggit iconVent
installation sleeve ICVH (4.2) can also be used instead of
the Pluggit iconVent installation stone ICVS (4.1).
This is designed as round EPP sleeve 198
mm.
6
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.1. SINGLE-ROOM VENTILATION UNIT ICONVENT DUO
Rotation direction A
1 Single-roo
m ventilation unit iconVent Duo
2 Functional
unit supply air operation
3 Supp
ly air
4 Functional
unit exhaust air operation
5 Exhaust air
Rotation direction B
1 Single-roo
m ventilation unit iconVent Duo
2 Function
al unit supply air operation
3 Supply air
4 Function
al unit exhaust air operation
5 Exhaust air
For the hygienically necessary exchange of air outside air is
fed into the fun
ctional unit (2) of the single-room ventilation
unit (1) and transported in the living room as supply air (3).
Humid and used exhaust air (5) is discharged through the
functional unit (4) out of
the building.
Approximately each 80 seconds the rotation direction of the
fans in the functional units (2) and
(4) is changed. This way,
also the direction of supply air (3) and exhaust air (5) is
changed.
The ceramic heat exchanger of the functional unit (4) is
heated by
the inside room temperature. This heat is sup-
plied at the change of rotation direction of the supply air (3).
Due to this operation a permanent heat recovery is
ac
hieved.
4. FUNCTION/PRINCIPLE
obenoben
obenoben
obenoben
obenoben
unten
oben
oben
unten
unten
oben
oben
unten
1
2
4
5
3
Outside wall
Inside wall
M+P-26A-1305
up
down
obenoben
obenoben
obenoben
obenoben
unten
oben
oben
unten
unten
oben
oben
unten
1
2
4
5
3
Outside wall
Inside wall
M+P-26A-1306
up
down
7
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.2. SINGLE-ROOM VENTILATION UNIT ICONVENT MONO
Rotation direction A
1 Single-room ventilation unit
iconVent Mono
2 Functional unit su
pply air operation
3 Supply air
Rotation direction B
1 Single-room ventilation unit
iconVent Mono
2 Functional unit exh
aust air operation
3 Exhaust air
The change of rotation direction of the fan in the single-
room ventilation unit icon
Vent Mono (1) is carried out corre-
spondingly as in the single-room ventilation unit
iconVent Duo.
The single-room ventilation units iconVent Mono (1) shall be
operated in
pairs for a regulation. This means one unit runs
in supply air operation whereas the second unit simultane-
ously runs in exhaust air operation. The change of rotation
dire
ction is also conducted simultaneously in pairs.
Only this way the balance between supply and exhaust air
volume stream required
according to DIN 1946-6 and
DIBt-approval can be guaranteed.
obenoben
obenoben
unten
oben
oben
unten
1 2
3
Outside wall
Inside wall
M+P-26A-1307
up
down
obenoben
obenoben
unten
oben
oben
unten
1 2
3
Outside wall
Inside wall
M+P-26A-1308
up
down
8
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.3. CROSS VENTILATION
Sample installation
1 Single-roo
m ventilation units
2 Regulation
3 Cross ventilation
4 Suppl
y air room, for example, living room and
dining room
5 Supp
ly air room, for example, bedroom
6 Suppl
y air room, for example, guest room
7 Suppl
y air room, for example, bathroom with window
8 Exhaust air room,
for example, kitchen with window
9 Overflow area, f
or example, corridor or hall
Thus the single-room ventilation units (1) can be controlled
b
y the regulation (2), so that a sufficient cross ventilation (3)
of the entire utilization unit is guaranteed.
For the realisation of cross ventilation (3)
the supply air
volume flows in this sample installation, for example, in the
living room and dining room (4), must be increased by +5 %.
In the opposite rooms, for example, in the bedroom (5) and
guest rooms (6), the exhaust air volume flows must by
higher by +5 %. Additionally suitable overflow openings, for
example, do
or undercuts are necessary.
In exhaust air rooms with windows, for example,
bathroom (7) and kitchen (8), no cross ventilation is neces-
sary. Here the single-room ventilation units (1) must be op-
erated in balance according to the DIBt-
approval. This
means they run independently with regard to air tech-
nology, independent from the settings of the supply air
rooms. In such a case either
two single-room ventilation
units iconVent Mono or one single-room ventilation unit
iconVent Duo must be installed.
In the overflow sector, for example, corridor or hall (9), an
own sin
gle-room ventilation unit can be renounced, be-
cause, as a rule, the cross ventilation
(3) is sufficient, in
order to achieve a sufficient air exchange in these rooms.
1
1
6
2
4 5
22
3
1 1
7
+5%+/-0% +/-0%
+5%
+5%
+5%
98
1
1
M+P-26A-1105
9
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.4. INSTALLATION TYPE SINGLE-ROOM
VENTILATION UNIT ICONVENT DUO
Sample installation
1 Single-room ventilation unit
iconVent Duo
2 Regulatio
n
3 Cross ventilation
4 Supply
air room, for example, living and dining room
5 Sup
ply air room, for example, bedroom
6 Supply
air room, for example, guest room or
children's room
7 Exhaust air
room, for example, bathroom with window
8 Exhaust air
room, for example, kitchen with window
9 Overflow are
a, for example, corridor or hall
Note:
The described installation type is valid for bathrooms
with integrated window.
1
1
6
2
4 5
22
3
1 1
7
+5%+/-0% +/-0%
+5%
+5%
+5%
98
1
1
M+P-26A-1105
10
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.5. INSTALLATION TYPE SINGLE-ROOM
VENTILATION UNIT ICONVENT MONO AND
ICONVENT DUO
Sample installation
1 Single-roo
m ventilation unit iconVent Mono
2 Single-roo
m ventilation unit iconVent Duo
3 Regulation
4 Supp
ly air room, for example, living and dining room
5 Supp
ly air room, for example, bedroom
6 Suppl
y air room, for example guest room or
children's room
7 Exhaust air room,
for example, bathroom with window
8 Exhaust air room,
for example, kitchen with window
9 Overflow area, f
or example, corridor or hall
Note:
The described installation type is valid for bathrooms
with integrated window.
1
1
6
4 5
3
3
2 2
7
+/-0%
+/-0%
98
1
1
M+P-26A-1106
11
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.6. INSTALLATION TYPE SINGLE-ROOM VENTILATION
UNIT ICONVENT DUO AND EXHAUST AIR VAN
Sample installation
1 Single-room ventilation unit
iconVent Duo
2 Exhaust
air fan according to DIN 18017-3
3 Regulatio
n
4 Supply
air room, for example, living and dining room
5 Sup
ply air room, for example, bedroom
6 Supply
air room, for example, guest room or
children's room
7 Exh
aust air room, for example, bathroom without window
8 Exhaust air
room, for example, kitchen with window
9 Overflow are
a, for example, corridor or hall
In flats with an inside bathroom without
window (7) an ex-
haust air fan (2) must be installed acc
ording to DIN 18017-3.
This has to generate an exhaust air volume flow
of 60 m³/h (V
AB
).
To realize a balanced air exchange additional volume flows
must
be generated in the supply air rooms, which balance
the air volume flow of the exhaust air fan. Only this way it
can be ensured that there is no vacuum in the utilization unit
and the single-room ventilation units (1) which are in ex-
haust air operation can continue to generate heat recovery.
Example:
The exhaust air fan (2) is connected with
two regulations (3)
of supply air rooms, as it is described here. The supply air
volume flow of the single-room ventilation units (1) must be
adjusted respectively +15 m³/h higher in the supply air op-
eration. By this, in total the 60 m³/h exhaust air volume flow
of
the exhaust air fan (2) is compensated.
The single-room ventilation unit (1) in the kitchen (8) con-
tinues to run in balance.
Note:
The described installation type is valid for inside bath-
rooms without window according to DIN 18017-3.
1
1
3
6
4 5
33
1
7 2
+/-0%
98
1
1
VAB = 60m /h
+15m /h
+15m /h+15m /h
+15m /h
3
3
33
3
M+P-26A-1107
12
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.7. INSTALLATION TYPE SINGLE-ROOM
VENTILATION UNIT ICONVENT MONO,
ICONVENT
DUO AND EXHAUST AIR VAN
Sample installation
1 Single-roo
m ventilation unit iconVent Mono
2 Single-roo
m ventilation unit iconVent Duo
3 Exhaust air fan according
to DIN 18017-3
4 Regulation
5 Supp
ly air room, for example, living and dining room
6 Supp
ly air room, for example, bedroom
7 Suppl
y air room, for example, guest room or
children's room
8 Exhaust
air room, for example, bathroom without window
9 Exhaust air room,
for example kitchen with window
10 Overflow area, f
or example, corridor or hall
The installation type with single
-room ventilation unit
iconVent Mono (1), iconVent Duo (2) and exhaust air fan (3)
is carried out correspondingly.
Example:
The exhaust air fan (3) is also connected with the
re
gulation (4), which also controls the single-room ventila-
tion units (1) for the cross ventilation. The supply air volume
f
low of the single-room ventilation units (1) must be adjusted
respectively +30 m³/h higher, as soon as and as long as the
e
xhaust air fan (3) is in operation.
Thus, in total the 60 m³/h (V
AB
) exhaust air volume flow of the
exhaust air fan (3) is compensates and hear recovery is guar-
anteed.
The single-room ventilation units iconVent Mono (1) and
i
conVent Duo (2) can be adjusted to various additional volume
flows depending on the number of installed units.
The single-room ventilation unit iconVent Duo (2) in the
ki
tchen (9) continues to run in balance.
Note:
The described installation type is valid for inside bath-
rooms without window according to DIN
18017-3.
1
1
4
4
7
5 6
2
8 3
V
AB
3
= 60m /h
+/-0%
109
1
1
3
+30m /h
3
+30m /h
M+P-26A-1108
13
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.8. REGULATION
1 Plug connector functional unit 1 (exhaust air)
2 Plug conn
ector functional unit 2 (supply air)
3 Plug conn
ector functional unit 3 (exhaust air)
4 Plug conn
ector functional unit 4 (supply air)
5 Plug conn
ector functional unit 5 (exhaust air)
6 Plug conn
ector functional unit 6 (supply air)
7 External entry, potential-
free 0/10 V
Plug the time-delay relay at the connection E1 (arrow).
8 Regulatio
n
The single-room ventilation units iconVent Mono and
iconVent
Duo as well as the exhaust air fan are controlled by
a regulation ICVC (8).
This has six plug connectors (1-6) for the connection of the
single-roo
m ventilation units as well as one plug
connector (7) for the connection of the exhaust air fan.
The connection of two single-room units iconVent Mono or
on
e iconVent Duo always shall be carried out at the horizon-
tally opposite plug connectors.
For the single-room ventilation units, which are always in-
stalled in pairs in the exhaust air rooms, for example,
kitchen,
bathroom and toilet with window, always both
upper plug connectors (1) and (2) shall be used.
As supply line for the supply voltage of the regulation (8) an
insulated cable 3 x 1.5 m
m² shall be applied.
Depending on the cable length the following insulated
c
ables are applied as control wire for the single-room
ventilation units:
Cable length 0-12 m: 3 x 0.25 mm²
Cable length 12-20 m: 3 x 0.6 mm²
Cable length 20-25 m: 3 x 0.8 mm²
The regulation is carried out by the rotary switch (10).
Depending on the required air volume flow various oper-
ating modes can be adjusted, see from page 14 onwards.
2
7
4
6
E1 E2
1
3
5
3x1,5mm
2
8
M+P-26A-1210
Note:
Level C-F are without function assignment.
0
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
10
M+P-26A-1111
14
BIA Single room ventilation unit iconVent Mono and iconVent Duo
4.8.1. Regulation schemes
Legend
1 icon
Vent regulation
2 Additional volume
flow supply air
3 Additional volume
flow exhaust air
Example connection level 2
1 Conne
ction insulated cable
Cable length 0-12 m: 3 x 0.25 mm²
Cable length 12-20 m: 3 x 0.6 mm²
Cable length 20-25 m: 3 x 0.8 mm²
Analogous to the below described example of level 2 the
conne
ction of all levels is carried out.
531
642
+ 0
- 0
1
2
3
M+P-26A-1180
15
BIA Single room ventilation unit iconVent Mono and iconVent Duo
Level 0
Level 1
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 0 Balance Balance Balance Balance Balance Balance
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 0 Balance Balance Balance Balance Balance Balance
A
B
531
642
531
642
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 1 Balance Balance +5 % +/- 0 % +/- 0 % +5 %
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 1 Balance Balance +/- 0 % +5 % +5 % +/- 0 %
A
B
531
642
531
642
+ 0
- 0
+ 0
- 0
+ 5%
- 0
+ 0
- 0
+ 0
- 0
- 0
+ 5%
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 5%
- 0
- 0
+ 5%
+ 0
- 0
16
BIA Single room ventilation unit iconVent Mono and iconVent Duo
Level 2
Level 3
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 2 Balance Balance +10 m³/h +/- 0 % +10 m³/h +/- 0 %
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 2 Balance Balance +/- 0 % +10 m³/h +/- 0 % +10 m³/h
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 3 Balance Balance +12.5 m³/h +/- 0 % +12.5 m³/h +/- 0 %
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 3 Balance Balance +/- 0 % +12.5 m³/h +/- 0 % +12.5 m³/h
17
BIA Single room ventilation unit iconVent Mono and iconVent Duo
Level 4
Level 5
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 4 Balance Balance +15 m³/h +/- 0 % +15 m³/h +/- 0 %
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 4 Balance Balance +/- 0 % +15 m³/h +/- 0 % +15 m³/h
A
B
531
642
531
642
+ 0
- 0
+ 0
- 0
+ 15m³/h
- 0
+ 0
- 0
+ 15m³/h
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 15m³/h
- 0
+ 0
- 0
+ 15m³/h
- 0
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 5 Balance Balance +20 m³/h +/- 0 % +20 m³/h +/- 0 %
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 5 Balance Balance +/- 0 % +20 m³/h +/- 0 % +20 m³/h
A
B
531
642
531
642
+ 0
- 0
+ 0
- 0
+ 20m³/h
- 0
+ 0
- 0
+ 20m³/h
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 0
- 0
+ 20m³/h
- 0
+ 0
- 0
+ 20m³/h
- 0
18
BIA Single room ventilation unit iconVent Mono and iconVent Duo
Level 6
Level 7
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 6 Balance Balance +30 m³/h +/- 0 % +30 m³/h +/- 0 %
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 6 Balance Balance +/- 0 % +30 m³/h +/- 0 % +30 m³/h
Rotation direction A Rotation direction A Rotation direction A
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Supply air Exhaust air Supply air Exhaust air Supply air Exhaust air
Level 7 +10 m³/h +/- 0 % +10 m³/h +/- 0 % +10 m³/h +/- 0 %
Rotation direction B Rotation direction B Rotation direction B
Plug
connector
Functional level
1
Functional level
2
Functional level
3
Functional level
4
Functional level
5
Functional level
6
Position Exhaust air Supply air Exhaust air Supply air Exhaust air Supply air
Level 7 +/- 0 % +10 m³/h +/- 0 % +10 m³/h +/- 0 % +10 m³/h
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29