Input Power: 110V or 220V AC, 47–440 Hz, 60W
Output Power: ≤28kV DC, ≤30mA
Conversion Efficiency: 91%
Dimensions: 7.8″ × 6.3″ × 3.6″ (197×161×91 mm)
Net Weight: 4.6 lb. (2.1 kg)
Warnings
ONLY install/remove this device when all power to your engraver is turned off & cut.
<5 min. ensure
that your engraver is properly grounded for normal operation. Use only with
engraving machines that employ a three-prong plug with with a ground terminal. Use
with an EMI filter is recommended.
Be careful that the positive and negative output terminals are properly connected to
the proper poles of your laser device prior to use. Be extremely careful around the
high-voltage anode wire and its connections.
Ensure that your CO₂ laser's water cooling system is operating properly during use. In
systems equipped with a protective sensor in their water system, this power supply will
automatically cut off power to the laser if a malfunction is detected by the circuit. In
systems without such a circuit, however, the water cooling system is no less important
and its proper operation should be manually ensured prior to each use.
Anode Connection
(red wire)
Cathode Connection
(white wire)
With its high efficiency, frequency, and speed, this power supply is an essential part of your
laser engraver, converting standard power into the high-voltage power needed for your laser
tube. The lightweight, compact MYJG-60W laser power supply is easy to operate. It is highly
compatible with a variety of 60W CO₂ lasers, including both active-high and active-low
machines. Its half-bridge soft switching capability improves efficiency and response. It
automatically inspects your laser signal and water cooling system and works without similar
devices' usual heat-generating heavy ballast resistance. This laser power supply connects
directly to your system and includes standard installation holes. Using it ensures quick operation
and maximizes the performance of your laser device, extending its service life.
Quality Assurance Testing
This device has undergone rigorous quality-assurance testing:
It has been tested to withstand a minute of 1500V AC power at ≤10 mA.
It has been found safe with ≥50 MΩ of resistance at 500V DC power.
It has been tested to operate at capacity for 12 hours at 140℉ (60℃).
It has been turned on and off 500 times in ≤7 seconds.
It has been shaken in every direction ±0.5 mm 10–55 times a second for 2 hours.
The ground wire has been found to carry a current of ≤0.5 mA when this device is
used with 110V AC power and ≤1 mA when used with 220V AC power.
Identical devices have shown a mean time before failure of 30,000 hours' use .
FG AC AC H L P G IN 5V
CONTACT US
Thank you for choosing our products! If you have any questions or comments,
contact us at help@cs-supportpro.com and we'll resolve your issue ASAP!
For a .pdf copy of the latest version of these instructions, use the appropriate
app on your smartphone to scan the QR code to the right.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Laser MYJG-60W Power Supply User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI