Issue Description
CQ00473058 A local controller may reset, when creating and deleting portable volumes from a remote Storage
Center, due to a double-queuing error if the request fails.
CQ00472032 Security vulnerability may occur because Secure Socket Layer (SSL) supports a weak cipher suite that
uses an encryption algorithm with a short key length. For information, see http://
support.microsoft.com/kb/811834.
CQ00471760 Security vulnerability can occur due to a minor NTP vulnerability in processing remote conguration
packets referenced in SA-15:07. Security: CVE-2014-9293, CVE-2014-9294, Security: CVE-2014-9295,
CVE-2014-9296, Security: FreeBSD-SA-14:31.ntp.
CQ00471380 Enabling additional debug logging on iSCSI IO cards may lead to server connectivity issues on other
controller front-end ports.
CQ00471076 The Storage Center System Manager user interface does not allow Volume Manager privileged users
to view volumes or replays on active volumes and issues an error message.
CQ00470606 On rare occasions, replacing a failed power supply in a dual-controller Storage Center causes both
controllers to reboot.
CQ00470469 In rare cases, the CPU temperature monitor may cause a controller reboot.
CQ00469934 Security vulnerabilities can occur on Apache servers due to implementing OpenSSL version 1.0.
CQ00469349 Data Progression may move active pages out of highest cost writable class.
CQ00469084 Upgrading from CT-SC040 controller to SC8000 controller may disable Phone Home and Secure Shell
(SSH).
CQ00468372
CQ00467957
A controller may fail to initialize after a software upgrade due to an SCUpdate API error.
CQ00467814 The Storage Center System Manager user interface does not provide a tier redundancy option and
cannot be modied causing all tiers to default to dual-redundancy.
CQ00466596 An unplanned controller reboot may occur if one of the controller’s system times is adjusted manually
during the controller hardware upgrade process.
CQ00465201 After a nonservice aecting software upgrade, servers may not initialize because the wait time
between upgrades on drives is too short, causing a backup of IOs and the server to abort IOs.
CQ00463318 A controller may reboot due to cache handling errors.
CQ00462385 SMTP service may become unresponsive.
CQ00461526 On rare occasions, replacing a failed power supply in a dual-controller Storage Center causes both
controllers to reset.
CQ00460367 For SC4020 controllers, iSCSI IO card drivers are hardcoded with an incorrect value.
CQ00460116 On rare occasions, the Storage Center System Manager user interface does not properly locate disks
in the system and issues a warning.
CQ00458240 A controller may reset after a failover completes due to a port reset.
CQ00458175 Data Progression may not start when a volume creation operation does not complete properly.
CQ00449838 Replays may fail and volumes may become marked as secondary because of an API collision due to a
server being deleted (or in the process of being deleted) and a UsageDesired conguration change.
CQ00449831 Asynchronous Replication may not resume after it is paused due to an incorrect variable attribute.
CQ00420799 Upgrading from CT-SC040 controller to SC8000 controller may cause a controller to fail because port
objects set for cleanup are not deleted.
CQ00415443 IO latency issues could occur when a drive medium error is detected and the system incorrectly sets
the current IO to a low recovery level.
14 Storage Center 6.7 Release Notes