Cooper&Hunter CH09MSPHCT230VI Quick start guide

Type
Quick start guide

This manual is also suitable for

SPLIT AIR CONDITIONER
WITH HEAT PUMP
Quick-Start
Guide
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Be sure to save this manual for
future reference.
S L E E P
T UR B O
L E D
T IME R
O N
T IME R
O F F
FA N
S P E E D
S WI NG
DIR E C T
MO DE
S HO R T
C UT
T E MP
ON/O F F
www.cooperandhunter.us
SOPHIA
1
CONTENTS
Use the remote control within a distance of 8
meters from the appliance, pointing it toward the
receiver. Reception is confirmed by a beep.
Location of the remote control
8m
The remote control is powered by two dry batteries (R03/LR03X2) housed in the
rear part and protected by a cover.
(1) Remove the cover by pressing it and sliding it off.
(2) Remove the old batteries and insert the new batteries, placing the (+) and (-)
ends correctly.
(3) Reattach the cover by sliding it back into position.
NOTE: When the batteries are removed, the remote control erases all progra-mming.
After new batteries are inserted, the remote control must be reprogrammed.
Replacing batteries
Handling the remote control
CAUTIONS
The air conditioner will not operate if curtains, doors, or other materials
block the signals from the remote control to the indoor unit. Prevent any
liquid from falling into the remote control. Do not expose the remote
control to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct
sunlight, the air conditioner may not function properly. Use curtains to
prevent sunlight from falling on the receiver.
If other electrical appliances react to the remote control, either move
those appliances or consult your local dealer.
2
CAUTIONS
Do not mix old and new batteries or batteries of different types.
Do not leave the batteries in the remote control if they will not be used for
2 or 3 months.
Do not dispose batteries as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
T
U
R
B
O
S
L
E
E
P
S
H
O
RT
C
U
T
T
I
M
E
R
O
N
TI
M
E
R
O
FF
L
OCK
R
E
SE
T
L
E
D
F
O
L
L
O
W
M
E
F
A
N
S
P
E
ED
D
I
R
E
C
T
S
WI
N
G
MO
D
E
T
E
MP
O
N
/
O
F
F
2
3
4
7
8
8
9
10
11
Handling the remote control ..........................................................
Remote control specifications.......................................................
Function buttons ............................................................................
Indicators on LCD ...........................................................................
How to use the buttons ..................................................................
Auto/Cool operation........................................................................
Dry/Fan operation............................................................................
Heat operation ................................................................................
Setting the timer function ..............................................................
26.2 ft (
8 m)
Remote controller specifications
Performance feature
NOTE:
Button design migh
t be slightly different from the actual one you
purchased, depending on individual models.
All the functions described are accomplished by the indoor unit.
If the indoor unit does not have this feature, no corresponding
operation will occur when the relative button is pressed on the remote
control.
1
2
4
5
3
9
10
8
6
7
11
12
Function buttons
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
MODE button
ON/OFF button
AUTO
COOL
DRY
HEAT
SWING button
DIRECT button
movement.
.
SLEEP button
FAN
NOTE: While the unit is running
under SLEEP mode, it will be
cancelled if the MODE, FAN, or
ON/OFF button is pressed.
TEMP
TEMP
Increases temperature in 2°F (1°C)
increments. Max. temperature is 86°F (30°C)
3.0V (Dry batteries R03/LR03X2)
23°F - 140°F (-5°C ... 60°C)
Operating Mode: AUTO, COOL, DRY, HEAT (Except in cooling-only model)
without), and FAN
Timer setting function in 24 hours
Indoor setting temperature range: 62°F - 86°F (17°C - 30°C)
Full function of LCD (Liquid Crystal Display).
1.
2.
3.
4.
Decreases temperature in 2°F (1°C)
increments. Min. temperature is 62°F (17°C).
NOTE: Please do not select HEAT mode
if the machine you purchased is a cooling-
only model. Heat mode is not supported by
the cooling-only appliance.
Activate/Disable sleep function. it can
maintain the most comfortable
temperature and save energy.
For detalls, see "Sleep operation" in
"USER'S MANUAL"
5 6
Function buttons
SHORTCUT button
FAN SPEED button
Selects fan speeds in the following
order:
AUTO LOW MED HIGH
TIMER ON button
LED Button
Turns indoor unit s LED display on and
off.
TIMER OFF Button
Sets timer to turn unit off. Each press
will increase the auto-timed setting in
30-minute increments When the
setting time displays 10H, each press
will increase the auto-timed setting in
60-minute increments. To cancel the
auto-timed program, simply adjust the
auto-off time to 0.0.
1
2
4
5
3
9
10
8
6
7
11
12
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
1
2
4
5
3
9
10
8
6
7
11
12
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
TURBO button:
Activate/Disable TURBO function.
Turbo function enables the unit to
reach the preset temperature in the
shortest possible time. If the indoor unit
does not have this feature, no
corresponding operation will occur
when the button is pressed.
Sets and activates your favorite pre-
settings.
The first time the unit is connected to the
power, when you press this button, the
fan speed will be set to AUTO mode,
75.2°F (24°C).
When the remote control is on, pressing
this button will cause the system to
automatically revert back to the previous
settings, including operating mode,
setting temperature, fan speed level, and
sleep feature (if activated).
If this button is held for more than 2
seconds, the system will automatically
restore the current operation settings,
including operating mode, setting
temperature, fan speed level, and sleep
feature (if activated).
,
7
8
9
10
11
12
Sets timer to turn unit on. Each press
will increase the auto-timed setting in
30-minute increments. When the
setting time displays 10H, each press
will increase the auto-timed setting in
60-minute increments. To cancel the
auto-timed program, simply adjust the
auto-on time to 0.0.
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
7 8
Indicators on LCD
Note:
All indicators shown in the figure are for the purpose of clear presentation. During
the actual operation, only the relative functional signs are shown on the display
window.
Lock Display
Displayed when LOCK
mode is activated (
Not
available for this unit
).
How to use the buttons
1. Press the MODE button to select
COOL mode.
2.Set your desired temperature using
the Temp or Temp button.
3. Press the FAN button to select the
fan speed: AUTO, LOW, MED, or
HIGH.
4. Press the ON/OFF button to start the
unit.
In AUTO
mode, the unit will automatically
select the COOL, FAN, HEAT, or DRY mode
based on the set temperature.
1. Press the MODE button to select Auto mode.
2. Set your desired temperature using the
Temp or Temp button.
3. Press the ON/OFF button to start the unit.
,
NOTE: FAN SPEED can t be set in AUTO mode.
3
4
3
2
2
1
1
SETTING TEMPERATURE
AUTO operation
The operating temperature range for units is
62-86
°
F (17-30
°
C)
. You can increase or decrease
the set temperature in 2
°
F (1
°
C) i ncrements.
COOL operation
auto
c ool
Temperature/Timer display
Displays the set temperature by
default, or timer setting when
using TIMER ON/OFF functions:
Temperature range:
62
°
F - 86
°
F
Timer setting range: 0-24 hours
This display is blank when
operating in FAN mode.
Transmission
Indicator Lights up
when remote sends
signal to indoor unit
SLEEP display
Displays when SLEEP
function is activated.
MODE display
Displays the current mode, including:
Auto
Cool
Dry
Heat
Fan
ON/OFF display
Appears when the unit
is turned on and
disappears when it is
turned off.
TIMER ON/OFF
display Displays
when TIMER ON/OFF
is set
FOLLOW ME
display
Indicates that
the FOLLOW ME
function is on
FAN SPEED display
Displays selected FAN
SPEED:
HIGH MED LOW
This display is blank
when set to Auto
speed or dry mode.
(Not available for
this unit)
F
auto cool dry heat fan
sleep follow me lock run
SET TEMP. TIMER ONOFF
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
9 10
1. Press the MODE button to select DRY
mode.
2. Set your desired temperature using the
T
emp or Temp button.
3. Press the ON/OFF button to start the unit.
,
NOTE: FAN SPEED can t be changed in
DRY mode.
1.
Press the MODE button to select FAN
mode.
2.
Press the FAN button to select the fan
speed: AUTO, LOW, MED, or HIGH.
3.
Press the ON/OFF button to start the
unit.
NOTE: Temperature can't be set in FAN
mode. As a result, your remote control's
LCD screen will not display temperature.
How to use the buttons
3
3
2
2
1
1
DRY operation (dehumidifying)
FAN operation
How to use the buttons
4
3
2
1
1. Press the MODE button to select
HEAT mode.
2. Set your desired temperature using
the Temp or Temp button.
3. Press the FAN button to select the
fan speed: AUTO, LOW, MED, or HIGH.
4. Press the ON/OFF button to start the
unit.
HEAT operation
NOTE: As outdoor tempe rature drops, the
performance of your unit s HEAT function
may be affected. In such instances, we
recommend using this air conditioner in
conjunction with other heating appliances.
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
dry
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
fan
heat
11
12
NOTE: When setting the TIMER ON or
TIMER OFF functions, up to 10 hours, the
time will increase in 30-minute increments
with each press. After 10 hours and up to
24, it will increase in 1-hour increments.
The timer will revert to zero after 24 hours.
You can turn off either function by setting
its timer to "0.0h".
2.
Press the TIMER ON button repeatedly to
set the time that you want the unit to turn
on.
3.
After 2 seconds, the TIMER ON
function will be activated. The digital
display on your remote control will then
return to the temperature display.
2.
Press the TIMER OFF button repeatedly to
set the time that you want the unit to turn off.
3.
After 2 seconds, the TIMER OFF
function will be activated. The digital
display on your remote control will then
return to the temperature display.
Example
hours.
: Setting unit to turn on after 2.5
Example
hours.
: Setting unit to turn off after 5
2 sec
ON/OFF
MODE
FAN
SHORT
CUT
TIMER ON
TIMER OF
F
TEMP
S
L
E
EP
1 sec
x5
1
3
2
4
TIMER OFF function
The TIMER OFF function allows you to set
a period of time after which the unit will
automatically turn off, such as when you
wake up.
1. Press the TIMER ON button. By
default, the last time period that you
set and an "h" (indicating ho urs) will
appear on the display.
Note: This number indicates the
amount of time after the current time
that you want the unit to turn on. For
example, if you set TIMER ON for 2
hours, "2.0H" will appear on the
screen, and the unit will turn on after
2 hours.
1. Press the TIMER OFF button. By default,
the last time period that you set and an
"h" (indicating ho urs) will appear on the
display.
Note: This number indicates the
amount of time after the current time
that you want the unit to turn off.
For example, if you set TIMER OFF for
2 hours, "2.0H" will appear on the
screen, and the unit will turn off after
2 hours.
2 sec
x10
ON/OFF
MODE
FAN
SHORT
CUT
TIMER ON
TIMER OF
F
TEMP
S
L
EEP
1 sec
1
3
2
4
Continue to press
TIMER ON or TIMER
OFF button until
desired time is
reached.
TIMER ON function
The TIMER ON function allows you to set a
period of time after which the unit will
automatically turn on, such as when you
come home from work.
Setting the TIMER function
Your air conditioning unit has two
timer-related functions:
TIMER ON- sets the amount of time after
which the unit will automatically turn on.
TIMER OFF- sets the amount of time after
which the unit will automatically turn off.
SLEEP
TURBO
LED
TIMER
ON
TIMER
OFF
TIMER
OFF
TIMER
ON
TIMER
OFF
TIMER
ON
FAN
SPEED
SWING
DIRECT
MODE
SHORT
CUT
TEMP
ON/OFF
13
Example: Setting the unit to turn on after 6 hours, operate for 2 hours, then turn off
(see the figure below)
Your remote display
Timer is set to turn ON 6
hours from current time
Timer is set to turn OFF
8 hours from current time
Current
time 1PM
2PM 3PM
4PM 5PM
6PM 7PM 8PM 9PM
Timer starts
Unit turns Unit turns
ON
OFF
6 hours later
8 hours later
TIMER ON
TIMER OFF
14
Setting both TIMER ON and TIMER OFF at the same time
Keep in mind that the time periods you set for both functions refer to hours after the current
time. For example, suppose that the current time is 1:00 PM, and you want the unit to turn on
automatically at 7:00 PM. You want it to operate for 2 hours, then automa-tically turn off at
9:00 PM.
Do the following:
ON/OFF
ON/OFF
MODE
MODE
SHORT
SHORT
CUT
CUT
TIMER ON
TIMER ON
TEMP
TEMP
3 sec
3 sec
4
8
3
7
X12
X16
2
6
1
5
TIMER
ON
TIMER
OFF
TIMER
OFF
TIMER
ON
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Cooper&Hunter CH09MSPHCT230VI Quick start guide

Type
Quick start guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI