Webasto Ram ProMaster London/Vancouver/Sedona - Front Mounting Kit - Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide

Webasto Ram ProMaster London/Vancouver/Sedona - Front Mounting Kit - is a mounting kit designed for Webasto heating and cooling systems. It is compatible with Ram ProMaster London, Vancouver, and Sedona vehicles. The kit includes a mounting plate, brackets, bolts, and screws for easy installation of the Webasto unit. The London/Sedona assembly has a downhill slope to the rear drain holes for efficient water drainage. The kit is intended for use by trained or certified dealers and personnel who have the proper tools and equipment to complete the installation process.

Webasto Ram ProMaster London/Vancouver/Sedona - Front Mounting Kit - is a mounting kit designed for Webasto heating and cooling systems. It is compatible with Ram ProMaster London, Vancouver, and Sedona vehicles. The kit includes a mounting plate, brackets, bolts, and screws for easy installation of the Webasto unit. The London/Sedona assembly has a downhill slope to the rear drain holes for efficient water drainage. The kit is intended for use by trained or certified dealers and personnel who have the proper tools and equipment to complete the installation process.

Contents
INTRODUCTION ............................................................................................................................................................ 2
1.0 General Service and Safety Precautions................................................................................................................ 2
1.1 Scope .................................................................................................................................................................. 2
1.2 Applicability of Manual ........................................................................................................................................ 2
1.3 Meaning of Warnings, Cautions and Notes ......................................................................................................... 2
1.4 Safety .................................................................................................................................................................. 2
1.5 Installation General References ............................................................................................................................ 2
London / Sedona Mounting Kit Assembly ...................................................................................................................... 3
Warning: Cancer and Reproductive Harm. www.P65Warnings.ca.gov
Installation and repair of Webasto heating and cooling systems requires special Webasto
training, technical information, special tools and special equipment.
NEVER attempt to install or repair Webasto heating or cooling system unless you have the
proper certifications, technical skills, tools, and equipment required to properly complete the
necessary procedures.
ALWAYS carefully follow Webasto installation and repair instructions and heed all WARNINGS.
Webasto rejects any liability for problems and damage caused by the system being installed by
untrained personnel.
Webasto Heating and Cooling
Installation Guide for Kit Numbers:
5013774A ProMaster London / Sedona Mounting Kit
INTRODUCTION
1.0 General Service and Safety Precautions
WARNING
Never service, repair, or troubleshoot this system unless you are a professional service person. Improper servicing can
lead to serious injury or death from fire, electric shock, or explosion.
1.1 Scope
These non-binding installation instructions are intended to support trained or certified dealers, and personnel in the
installation of the Webasto VAC, HVAC, and heating units. Provided these instructions are followed properly and all
options listed in the parts breakdown are installed, this system will provide supplemental heating and cooling.
1.2 Applicability of Manual
These non-binding installation instructions apply to the make/model listed on the front cover of this installation
manual. Due to optional equipment, there may be build variations between this installation manual and the vehicle
you are working on. Technical modifications that differ from the instructions set forth exclude all liability claims.
Acknowledged engineering conventions must be observed for the installation work. Carefully read all documentation
prior to installation.
CAUTION
Location of the Webasto provided components, wiring and control devices are important for proper operation. Failure
to comply with the installation guidelines provided may result in poor operation or damage to the Webasto unit, the
vehicle, or vehicle components.
Non-compliance with the installation instructions and information contained therein will void the warranty. The same
applies for repairs performed by untrained personnel and repairs not using original equipment spare parts.
1.3 Meaning of Warnings, Cautions and Notes
WARNING:
This heading is used to highlight that non-compliance with instructions or procedures may cause injuries or lethal
accidents to personnel.
CAUTION :
This heading is used to highlight that non-compliance with instructions or procedures may cause damage to
equipment.
NOTE:
This heading is used to highlight and draw specific attention to information.
1.4 Safety
All relevant state and provincial regulations, if any, governing the installation of this device must be observed! The
general safety regulations for the prevention of accidents and the relevant operating safety instructions must be
observed at all times.
1.5 Installation General References
Bare sheet metal, for example around drilled holes, must be treated with anti-corrosive coating.
Secure hoses, cables and wiring harnesses with cable ties and fit protective hoses around them at chafing
points.
Fit edge protectors (split fuel hose, grommet, split-loom, etc.) to sharp edges.
Replace hose clamps as necessary. Hose clamps should be inspected before re-use. Look for damage to the
screw and to the band due to fatigue, corrosion, or improper installation.
Item
Description
Qty.
1 Mounting Plate
A
roof rib and are aligned
2
2
Bolt M6 X 1.0 X 20
2
3
Bracket – London / Sedona Mounting
2
4
Screw – Self Drilling
2
London / Sedona Mounting Kit Assembly
Fig. 1
WARNING: Review and adhere to all manufacturer's recommendations and specifications when
mounting this unit or any components to the vehicle structure.
NOTE: The London / Sedona assembly is sold separately
*i8 bolts and washers are removed from the London / Sedona unit and reused as mounting bolts.
Position the London / Sedona unit with a downhill slope to the rear drain holes.
If you have any questions, contact our technical support team at (800) 860-7866 or via email at
technical@webasto.com
In multilingual versions the English language is binding. The telephone number of the respective country is shown on the Webasto
service center leaflet or can be found on the website of your Webasto subsidiary.
Dans le cas d’une version rédigée en plusieurs langues, l’anglais est alors la langue qui fait foi. Pour trouver le numéro deléphone
du pays concerné, veuillez consulter le dépliant des points-service Webasto ou la page web de la représentation Webasto de votre
pays.
Webasto Thermo & Comfort N.A., Inc.
15083 North Road
Fenton, MI 48430
Technical Assistance Hotline
USA: (800) 860-7866
Canada: (800) 667-8900
5013776C | Org. 07/2020 | Rev. 8/2023 www.webasto.us
www.techwebasto.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Webasto Ram ProMaster London/Vancouver/Sedona - Front Mounting Kit - Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide

Webasto Ram ProMaster London/Vancouver/Sedona - Front Mounting Kit - is a mounting kit designed for Webasto heating and cooling systems. It is compatible with Ram ProMaster London, Vancouver, and Sedona vehicles. The kit includes a mounting plate, brackets, bolts, and screws for easy installation of the Webasto unit. The London/Sedona assembly has a downhill slope to the rear drain holes for efficient water drainage. The kit is intended for use by trained or certified dealers and personnel who have the proper tools and equipment to complete the installation process.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI