Minpu Technology MPT LCR01A is a handheld LCR bridge meter that is capable of measuring inductance,capacitance, and resistance. It is a versatile device that can be used for a wide variety of applications, including:

  • Testing electronic components
  • Troubleshooting circuits
  • Designing and prototyping new products
  • The MPT LCR01A is a powerful and easy-to-use device that can be a valuable asset to any engineer or technician. Here are some of the key features of the MPT LCR01A:
  • High accuracy and resolution
  • Wide measurement range
  • Fast measurement speed
  • Easy-to-use interface
  • Compact and portable design

Minpu Technology MPT LCR01A is a handheld LCR bridge meter that is capable of measuring inductance,capacitance, and resistance. It is a versatile device that can be used for a wide variety of applications, including:

  • Testing electronic components
  • Troubleshooting circuits
  • Designing and prototyping new products
  • The MPT LCR01A is a powerful and easy-to-use device that can be a valuable asset to any engineer or technician. Here are some of the key features of the MPT LCR01A:
  • High accuracy and resolution
  • Wide measurement range
  • Fast measurement speed
  • Easy-to-use interface
  • Compact and portable design
MPT LCR01A/B
Handheld LCR bridge meter
User manual
Featured
1. Adapt DSP technology to achieve fast measuring speed, high accuracy and high
reliability.Measuring frequency can be set at 100K/10K/1K/120/100/20 Hz (LCR01A)
or 1M/500K/100K/10K/1K/100Hz(LCR01B)
2. Measuring parameterMain parameter ZLpLsCpCsDCR and subparameter
ESRDQθ can be displayed in any combination.
1
Contents
Page
1.
MPT LCR01A/B Introduction
2
1.1.
Function introduction
2
1.2.
Impedance definition
3
1.3.
Accuracy and specification
5
1.4.
Accessory
13
2.
Manual illustration
14
2.1.
Panel
14
2.2.
Power
15
2.3.
Open/Short calibration
17
2.4.
Display speed
18
2.5.
Relative mode
18
2.6.
Manual range operation
18
2.7.
DC impedance measurement
18
2.8.
AC impedance measurement
19
2.9.
Capacitance measurement
19
2.10.
Inductance measurement
20
2.11.
Accessory operated illustration
21
3.
Usage illustration
24
3.1.
Maintain illustration
24
3.2.
Notice
24
Appendix
1
Cable connection technique
25
Appendix
2
Open/Short circuit compensation
33
Appendix
3
Serial/Parallel mode selection
35
2
1.
MPT LCR01A/B Introduction
1.1.
Function introduction
MPT LCR01A/B is an innovative AC/DC impedance meteralso include
capacitance and inductance measurementIt differ from traditional meterMPT
LCR01A/B adapts DSP(Digital Signal Process) techniqueTechnicians and
engineers will get various conveniences from this advanced meter
Features of MPT LCR01A/B
Frequency100K/10K/1K/120/100/20 Hz(LCR01A)
1M/500K/100K/10K/1K/100Hz(LCR01B)
Level1Vrms/0.25Vrms/0.05Vrms/1.25Vdc(LCR01A)
1Vrms/0.3Vrms/0.1Vrms/1.5Vdc(LCR01B)
Measuring ParameterZLpLsCpCsDCR
ESRDQθ
Basic accuracy0.2(=10KHz)0.4(100KHz)
0.5%(500KHz)0.5(1MHz)
Dual LCD display
DSP fast measuring
Auto range/Range hold
Open/Short compensation
Display parameters
Z
Impedance
DCR
DC Resistance
Lp
Inductance parallel
Ls
Inductance series
Cp
Capacitance parallel
Cs
Capacitance series
θ
Impedance phase angle
ESR
: Effective Series Resistance
D
Dissipation factor
Q
Quality factor
Display assembly
Serial mode
Z-θ
, Z-ESR
, Z-D
, Z-Q
Cs-D
, Cs-Q
, Cs-θ
, Cs-ESR
3
Ls-D
, Ls-Q
, Ls-θ
, Ls-ESR
Parallel mode
Cp-D
, Cp-Q
, Cp-θ
Lp-D
, Lp-Q
, Lp-θ
1.2.
Impedance parameter definition
According to the different measuring signal of impedance meterIt can be separated
DC and AC impedance meterThe popular multimeter in market is a DC resistance
meterThe MPT LCR01A/B is an AC/DC impedance meterFor electronic Circuit
component and materialimpedance is an important parameter
In engineeringvector is used to express impedanceIt analysed real part Resistance(R)
and imagine part reactance(X) And the polar express impedance(Magnitude) and
Theta(Phase)Diagrams below show the relation
4
θ
Z
Real Axis
Rs
Imaginary Axis
Xs
ZRs , Xs
Z = Rs+jXs =Z∣∠θΩ
Rs =ZCosθ Z= Rs 2 + Xs 2
Xs =ZSinθ θ = Tan -1 Xs/Rs
ZImpedance
RsResistance
XsReactance
ΩUnit Ohm
5
Reactance can be separated as(Inductive) X
L
and(Capacitive) X
C
The definition as
X
L
=ωL=2πfL
and
LInductance (H)
CCapacitance (F)
fFrequency (Hz)
X
C
=(ωC) -1 =(2πfC) -1
Additionalother parameters are attached to passive componentQuality factor(Q) and
Dissipation Factor(D)Both are defined the purity of reactancethat is the energy
storage(reactance) and the energy consumption(resistance)ratiodefined as follow
Q=D -1 = (tanδ) -1
=Xs∣.Rs-1=ωLsRs-1=(ωCsRs) -1
=B∣.G-1
= Rp.∣Xs-1=Rp(ωLp) -1=ωCpRp
Quality factor is applied on inductive componentsand Dissipation factor is applied
on capacitive componentsBoth are reciprocal each other
Traditionalcomponent can be analysed as series equivalent and parallel equivalent
Both defined as follow
Series connection
parallel connection
1.3.
Specification and Accuracy
6
LCD display
parameter
Range
Z
0.000Ω 9999MΩ
L
0.000H 9999H(LCR01A)
0.0xxnH 9999H(LCR01B)
C
0.000pF 9999F
DCR
0.000Ω 9999MΩ
ESR
0.000Ω 9999Ω
D
0.000 9999
Q
0.000 9999
Θ
180.0° 180.0°
AccuracyAe):
Zx
Ae
Freq.
20M
10M
(Ω)
10M
750K
(Ω)
750K
100K
(Ω)
100K
20K
(Ω)
20K
10
(Ω)
10
1
(Ω)
1
0.1
(Ω)
DCR
2% ±
1
1% ±
1
0.5%
±1
0.2%
±1
0.2%
±1
0.5% ±1
1% ±1
20Hz(LCR01A)/100Hz
120Hz(LCR01A)
1KHz
10KHz
5% ±
1
2% ±
1
100KHz
UnD
5% ±
1
2% ±
1
0.4%
±1
0.4%
±1
2%±1
5% ±1
500KHz
(LCR01B)
UnD
UnD
2%
±1
1% ±
1
0.5%
±1
2%±1
5% ±1
1MHz
(LCR01B)
UnD
UnD
UnD
1% ±
1
0.5%
±1
2%±1
5%
±1
Accuracy show above is true when 1Vrms measuring level used
Ae X 1.25 if 250mVrms measuring level used
Ae X 1.50 if 50mVrms measuring level used
7
measuring L and Cif Dx0.1, then Ae X (1+Dx2)
Measuring ESRif Qx0.1, then Ae X (1+Qx2)
Measuring level set to 50mV, Ae undefined
Z accuracy
shown on table 1.
C accuracy
Zx∣=(2fCx) -1 (Ω)
CAeAe of Zx
ffrequency(Hz)
Cx:The measured capacitance(F)
Zx∣:The measured impedance(Ω)
Above accuracy is true when Dx0.1if D x0.1then CAe X (1+Dx2)
ExampleC accuracy calculate
Measuring condition
Frequency1KHz
Level1Vrms
SpeedSlow
Capacitance under test100nF
Then
Zx∣=(2fCx) -1
Zx(210310010-9) -11590 (Ω)
look up on table 1:
CAe=±0.2 (%)
8
L accuracy
Zx∣=2fL (Ω)
LAeAe of Zx
fFrequency(Hz)
Lx:The measured inductance(H)
Zx∣:The measured impedance(Ω)
Above accuracy is true when Dx0.1if D x0.1 then CAe X (1+Dx2)
ExampleL accuracy calculation
Measuring condition
Frequency1KHz
Level1Vrms
SpeedSlow
Inductance under test1mH
then
Zx∣=2fLx
Zx210310-36.283 (Ω)
look up on table 1:
LAe=±0.5 (%)
9
ESR accuracy
±XxAe 100-1 (Ω)
Xx2fLx(2fCx) -1
fFrequency(Hz)
Xx:The measured impedance(Ω)
Lx:The measured inductance(H)
CxThe measured capacitance(F)
Above accuracy is true when Dx0.1
ExampleCs-ESR accuracy calculation
Measuring condition
Frequency1KHz
Level1Vrms
SpeedSlow
Capacitance under test100nF
then
Zx∣=Xx(2fCx) -1
Zx(210310010-9) -11590 (Ω)
look up on table 1:
CAe=±0.2 (%)
ESR A e=±XxAe/100
±1590 X 0. 2 / 100 = ± 3.18 (Ω)
10
D accuracy
De=±A e /100
Above accuracy is true when Dx0.1if D x0.then CAe X (1+Dx)
ExampleC-D accuracy calculation
Measuring condition
Frequency1KHz
Level1Vrms
SpeedSlow
Capacitance under test100nF
then
Zx∣= (2fCx) -1
Zx(210310010-9) -11590 (Ω)
look up on table 1:
CAe=±0.2 (%)
D A e ±CAe /100
±0.2/100= ±0.002
11
Q accuracy
Qe=±(Qx2De)/(1 QxDe)
QxThe measured Q value
De:relative D accuracy
Above accuracy is true when QxDe1
ExampleC-Q accuracy calculation
Measuring condition
Frequency1KHz
Level1Vrms
SpeedSlow
Inductance under test1mH
then
Zx∣=2fLx
Zx210310 -36. 283 (Ω)
look up on table 1:
LAe=±0.5 (%)
De=±Ae/100=±0.005
If the measured Qx20
QAe=±(Qx2De/(1 QxDe) )=± ( 2/(1 0.1) )
12
Θ accuracy
θe (180/π)/(Ae/100) (Deg)
ExampleZ-θaccuracy calculation
Measuring condition
Frequency1KHz
Level1Vrms
SpeedSlow
Capacitance under test100nF
then
Zx∣=(2fCx) -1
Zx1/(210310010 -9)1590 (Ω)
look up on table 1:
ZAe=±0.2 (%)
θAe=±(180/π)/(ZAe/100)=±0.115 (Deg)
13
measuring signal
Level accuracy10
Frequency accuracy0.01
Output impedance100Ω±5
Measuring speeddepend on frequency
Fast:5times/second(1KHz)
Slow:2.5times/second(1KHz)
Power low notify
Input or battery power lower than 6.2Volt
Battery
Charge currentabout 60mA
Battery typeLithium-Ion
Life11 hr(LCR01A) 8 hr(LCR01B)
Adapter
Input110V/220Vac 50/60Hz
Output12Vdc
Operation environment
Temperature0 to 40 (operation)
-20 to 70 (storage)
Humidity:≦85 R.H. at 40
Size178mm × 86 mm × 45mm
7”× 3.4”× 1.8 (L×W×H)
Weight300g
14
1.4.
Accessory
LCR01A/B Operation manual
LCR01A or LCR01B one set
Lithium-Ion rechargeable battery
Shorted Bar
5 wire/0.75mSMD test probe
5 wire/0.75m Kelvin Clips test cable
AC power adaptor
15
2.
User operate illustration
2.1.
Panel
1.
Main parameter display LCD
11.
Subparameter display LCD
2.
Low voltage indicator
12.
Power ON/OFF switch
3.
Machine type
13.
Open/Short calibration button
4.
Level switch button
14.
Relative mode button
5.
Frequency switch button
15.
Θ/D/Q/ESR display switch button
6.
Display speed switch Button
16.
Auto/Range hold switch button
7.
Z/DCR/C/L display switch button
17.
Guard terminal
8.
Hpot/Hcur terminal
18.
Power adaptor input hole
9.
Lpot/Lcur terminal
10.
Battery house
16
2.2.
Power
Battery supply
Remove battery cupclean battery houseput the pull-up tape under battery
and put battery into the battery house in proper directionthen put on the battery
cupIf the battery is not chargeable remove the power adaptor input
connectorIf the battery is chargeablepower adaptor input connector can be
plug-in
17
Power adaptor supply
If battery not availableIt can be powered by power adaptorIf the power
adaptor is plug-in and the power switch on LCR01A/B is offIt will charge
battery on battery house
18
2.3.
Open/Short calibration
LCR01A/B function with Open/Short calibration to meet the measuring of
High/Low impedance measurement
Open calibration
Clean the measuring terminalmake it on open statepressCALbutton
about 1 secondmain parameter will displayCALOand a “bi” sound will
be heardCalibration time will depend on measuring frequencythe high
frequencythe lower calibration time neededAfter calibration a “bi” sound
will be heard again
Short calibration
Plug-in shorted bar firstpressCALabout 2 secondstillCALSshown
on main displayand a “bi” sound will be heardAfter calibration a “bi”
sound will be heard again
19
2.4.
Display refresh
LCR01A/B functions with Fast/Slow display refresh modeUser press the
Speedbutton will toggle speed modeonFastmodethe refresh
speed will be twice ofSlowmodethe more of the measuring frequency
the faster of the refresh speed
2.5.
Relative mode
LCR01A/B functions with measuring relative modeuser put a reference
component on the test terminalsThen press RelativebuttonAnd remove
this reference component from the test terminalsput other device under test on
test terminals thenthe main LCD display will display the result of subtraction
of the reference value from the measuring one
2.6.
Range hold mode
LCR01A/B functions with autorange/range_hold modeput a reference component on
the test terminalsthen wait until display stablepressRange HoldbuttonRH
will be shown on sub-parameter display LCDLCR01A will set this measuring
rangeRemove this reference component and put other component under test on test
terminalsthe measured result will gotten fasterBut care should be takenthe
measured range should in the range 2 and 1/2 of the reference value
2.7.
DC impedance measuring
PressL/C/Z/DCR】, tillDCRshown on main parameter display LCDthen LCR01A/B
will be in the DC impedance measuring mode
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45

Minpu Technology MPT LCR01A User manual

Category
Multimeters
Type
User manual

Minpu Technology MPT LCR01A is a handheld LCR bridge meter that is capable of measuring inductance,capacitance, and resistance. It is a versatile device that can be used for a wide variety of applications, including:

  • Testing electronic components
  • Troubleshooting circuits
  • Designing and prototyping new products
  • The MPT LCR01A is a powerful and easy-to-use device that can be a valuable asset to any engineer or technician. Here are some of the key features of the MPT LCR01A:
  • High accuracy and resolution
  • Wide measurement range
  • Fast measurement speed
  • Easy-to-use interface
  • Compact and portable design

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI