1601 MANUAL RELEASE KIT
Installation
AC Power ONLY Barrier Operator
DoorKing Part Number
1601-270
This kit is designed for the 1601 barrier gate operator WITH or WITHOUT the convenience open option. It provides an interlock
power cut-off switch when manually using crank tool to move the arm up or down.
Connect the interlock cut-off switch wires to the
existing black wire connected from main terminal #2.
Replace existing
single motor pulley
with double motor
pulley. Align motor
pulley with gear
reducer pulley.
Mount interlock
assembly using
existing hardware.
Mount spring clips with
lock nuts on existing
threaded studs inside
access door.
SHUT OFF ALL power to
the operator.
SHUT OFF the AC input
power to the operator
from the circuit breaker.
Kit Includes: Interlock assembly,
Double motor pulley, Crank tool,
2 spring clips with lock nuts.
DANGER
HIGH VOLTAGE!
AC Power
Switch
Interlock
Cut-Off
Switch
Interlock Cut-Off
Switch
(Black wires)
Convenience Open
Cut-Off Switch
(Yellow & Orange wires)
115 VAC
Power Terminal
Existing Wire
Existing Black Wire
from #2 Main Terminal
Spring
Clip
Black
Wires
New
120 S. Glasgow Avenue
Inglewood, California 90301 U.S.A.
NEU HOT
Main Terminal
Note: Convenience open
cut-off switch is NOT used.
Note: To manually operate,
see page 4.
115 VAC
Convenience
Outlets
Interlock
Assembly
Your Barrier Operator Setup:
AC Power ONLY
AC Power & Break-Away Arm
Convenience Open & Break-Away Arm
Convenience Open ONLY
Page:
1
2
3
4
Make sure ANY unused
wires are properly terminated
and do NOT have exposed
bare wires or metal connectors
that could cause the operator
to malfunction.
Convenience Open
Cut-Off Switch
nvenience Ope
ff Switch
Op
Copyright 2023 DoorKing®, Inc. All rights reserved.
Com
NO
11601-030-D-10-23
REVERSE
SENSITIVITY
1601-010
TIME
DELAY
POWER
1
ON
2 3 4 5 6 7 81
ON
2 3 4 5 6 7 8
NC
UP
LOOP
DOWN
LOOP
12345678910 11 12 13 14
SW 1
SW 2
Remove wire from Relay #2 to Main Terminal #2
and replace with Interlock Cut-Off Switch wires.
SHUT OFF the AC input
power to the operator
from the circuit breaker.
LN V- V+
SUPPLY
GROUND 1601-426 Power Supply 8.5A
Terminal 1 - Neutral
Circuit Board
L20
N - Neutral
Transformer 8.5 amp
L22
L - Line
Transformer 8.5 amp
L21
Ground
Transformer 8.5 amp
L23
Ground
Panel Stud
L24
N-Close
Main PCB
Red Light C1 L1
N-Open
Main PCB
Green Light C2 L2
Common
Main PCB
LED Light C10 L11
Terminal 14
Main PCB
Reverse Edge C4 L4
Terminal 1
Battery Backup PCB
Breakaway Sensor NC
C9 L15
Terminal 2
Battery Backup PCB
Breakaway Sensor NC
C8 L13
12V Negative (-)
Solid State Relay
C6 L6
12V Positive (+)
Solid State Relay
C3 L3
NONCC
V-
Transformer 8.5 amp
L18
V+
Transformer 8.5 amp
L17
Black
White
White
White
Pink
Blue
Black
Green
Green
Red/Blue
Grey/Pink
Grey
Red
Red
Yellow
Common
Main PCB
Terminal 9
Main PCB
Reverse Edge C5 L5
Arm Relay
Contacts
Make sure ANY unused wires are
properly terminated and do NOT
have exposed bare wires or metal
connectors that could cause
the operator to malfunction.
-V
12V Transformer
12
4 3
NEG POS
Relay
Octagon Reverse/LED Edge Arm
1601 Break-Away Bracket
1601-356
Harness
Pink NOT Used
Yellow NOT Used
AC Power & Break-Away Arm Barrier Operator
Main Terminal
Interlock Cut-Off
Switch
Convenience Open
Cut-Off Switch
nvenience Ope
ff Switch
Op
Note: Convenience open
cut-off switch is NOT used.
110VAC HOT
Solid State Relay
L16
Terminal 2
Main PCB
110VAC HOT L14
Com
NO
21601-030-D-10-23
REVERSE
SENSITIVITY
1601-010
TIME
DELAY
POWER
1
ON
2 3 4 5 6 7 81
ON
2 3 4 5 6 7 8
NC
UP
LOOP
DOWN
LOOP
12345678910 11 12 13 14
SW 1
SW 2
Remove wire from Relay #2 to Main Terminal #2
and replace with Interlock Cut-Off Switch wires.
First, SHUT OFF AC and DC power
switches on the operator,
Then, SHUT OFF the AC input power to
the operator from the circuit breaker.
ON
1234
12345678910
115 VAC
INPUT
J1
P1
RESET
CLEAR
STAT
AUTO OPEN
MOTOR DIR
AC ON ACT
LIMIT
TIMER
BATT STAT
RUN
TIME
HEART
BEAT
TRICKLE
CHARGE
STAT
SW2
ON
1473-010
LN V- V+
SUPPLY
GROUND 1601-426 Power Supply 8.5A
Terminal 1 - Neutral
Circuit Board
L20
N - Neutral
Transformer 8.5 amp
L22
L - Line
Transformer 8.5 amp
L21
Ground
Transformer 8.5 amp
L23
Ground
Panel Stud
L24
N-Close
Main PCB
Red Light C1 L1
N-Open
Main PCB
Green Light C2 L2
Common
Main PCB
LED Light C10 L11
Terminal 14
Main PCB
Reverse Edge C4 L4
Terminal 1
Battery Backup PCB
Breakaway Sensor NC
C9 L15
Terminal 2
Battery Backup PCB
Breakaway Sensor NC
C8 L13
12V Negative (-)
Solid State Relay
C6 L6
12V Positive (+)
Solid State Relay
C3 L3
NONCC
V-
Transformer 8.5 amp
L18
V+
Transformer 8.5 amp
L17
Black
White
White
White
Pink
Blue
Black
Green
Green
Red/Blue
Grey/Pink
Grey
Red
Red
Yellow
Common
Main PCB
Terminal 9
Main PCB
Reverse Edge C5 L5
NOTE: Will NOT work with older model
2340-010 convienence open board
Arm Relay
Contacts
21
-V
12V Transformer
1
4 3
2
NEG POS
Relay
Octagon Reverse/LED Edge Arm
1601 Break-Away Bracket
1601-356
Harness
Convenience Open & Break-Away Arm Barrier Operator
Orange to #2
Yellow to #1
Convenience Open
Cut-Off Switch
Main Terminal
Interlock Cut-Off
Switch
UP
DOWN
AUTO
AC POWER
DC POWER
ON
OFF
ON
OFF
110VAC HOT
Solid State Relay
L16
Terminal 2
Main PCB
110VAC HOT L14
Com
NO
Com
NO
31601-030-D-10-23
Interlock
Assembly
Door
Access
Door
Crank Tool
Storage
Manual Operation
First, SHUT OFF AC and DC power
switches on the operator,
Then, SHUT OFF the AC input power to
the operator from the circuit breaker.
DANGER
HIGH VOLTAGE!
1. Unlock and remove access door.
2. Remove crank tool from inside access door.
3. Flip interlock assembly door up, power will be disabled from operator.
4. Insert crank tool into motor pulley as shown.
5. Rotate crank tool to manually move operator arm up or down.
ON
1234
12345678910
115 VAC
INPUT
J1
P1
RESET
CLEAR
STAT
AUTO OPEN
MOTOR DIR
AC ON ACT
LIMIT
TIMER
BATT STAT
RUN
TIME
HEART
BEAT
TRICKLE
CHARGE
STAT
SW2
ON
1473-010
REVERSE
SENSITIVITY
1601-010
TIME
DELAY
POWER
1
ON
2 3 4 5 6 7 81
ON
2 3 4 5 6 7 8
NC NO
UP
LOOP
DOWN
LOOP
1234567891011121314
SW 1
SW 2
NONCC
NOTE: Will NOT work with older model
2340-010 convienence open board
21
Convenience Open ONLY Barrier Operator
AC Power
Switch
Interlock
Cut-Off
Switch
115 VAC
Power Terminal
Existing Wire
Black
Wires
Orange
Yellow
New
Com
NO
Convenience
Open Cut-Off
Switch
NEU HOT
Main Terminal
115 VAC
Convenience
Outlets
UP
DOWN
AUTO
AC POWER
DC POWER
ON
OFF
ON
OFF
Connect the interlock cut-off switch wires to the
existing black wire connected from main terminal #2.
Existing Black Wire
from #2 Main Terminal
Com
NO
41601-030-D-10-23
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

DKS 1601 Crank Kit User manual

Category
Motorcycle Accessories
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI