HRTP486SNG

Dacor HRTP486SNG, HRTP366S/LP/H, HRTP366SNGH User guide

  • Hello! I am an AI chatbot trained to assist you with the Dacor HRTP486SNG User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is the minimum cutout width required for the Dacor HRTP486SNG rangetop?
    What is the recommended cutout width for the best fit?
    Which downdraft vent is approved for use with the HRTP486SNG rangetop?
    Can the power cord and gas-supply conduit be routed through the bottom or back of the rangetop?
    What is the maximum horizontal distance between the edge of the rangetop and the cabinet?
PLANNING
GUIDE
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
HRTP Dimensions
Chassis Width
Model A
HRTP366 35 ” (91.1 cm)
HRTP486 47 ” (121.6 cm)
Heritage
®
36”, 48” Wide
Slide-In Gas Rangetop
Doc #: PGH-HRTP.01 Revised 22 May 2018 Page 1 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
HRTP366, HRTP486
WARNING
Observe all governing codes and
ordinances during planning/installation.
(Contact the local building department
for details.)
The rangetop must be installed as
instructed in this guide.
Model B C
HRTP366 36” (91.4 cm) 36” (91.4 cm)*, 42” (106.7 cm)**
HRTP486 48” (121.9 cm) 48” (121.9 cm)*; 54” (137.2 cm)**
* Minimum ** Recommended
Note Description
1 Measured from top of grate to combustible surface.
2
See Cabinet/Countertop Cutout Dimensions, Pgs. 3 – 4.
3
Not applicable for cabinets more than a horizontal distance
of 10” (25.4 cm) from edge of rangetop.
PLANNING
GUIDE
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
Model B (Cutout Width) D (Hole Offset)
HRTP366 36” (91.4 cm) 16 ” (42.2 cm)
HRTP486 48” (121.9 cm) 20-¹³/₁₆” (52.9 cm)
Heritage
®
36”, 48” Wide
Slide-In Gas Rangetop
Page 2 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
HRTP366, HRTP486
Cabinet/Countertop Cutout Dimensions
NOTE:
The power cord and gas-supply conduit may
be routed through the bottom or back of the
rangetop chassis.
PLANNING
GUIDE
All specications subject to change without notice. www.dacor.com Ph. 800.793.0093
Rangetop Approved Downdraft Vents*
HRTP366 MRV3615
HRTP486 MRV48
*Use only the downdraft vents specified.
Heritage
®
36”, 48” Wide
Slide-In Gas Rangetop
Page 3 of 3
All tolerances: ±¹/₁₆” (±1.6 mm), unless otherwise stated.
HRTP366, HRTP486
Model B (Cutout Width) D (Hole Offset) E (Downdraft Vent Cutout)
HRTP366 36” (91.4 cm) 16 ” (42.2 cm) 33 ” (85.1 cm)
HRTP486 48” (121.9 cm) 20 ¹³/₁₆” (52.9 cm) 43 ” (110.5 cm)
Cabinet and Countertop Layout (with downdraft vent)
NOTE:
The power cord and gas-supply conduit may be routed
through the bottom or back of the rangetop chassis.
/