Halsey Taylor HRFG_SEBP_VR_FR is a non-refrigerated Marblyte VR, Freeze Resistant Fountain with Back Panel suitable for both indoor and outdoor use. This durable fountain, with an extremely durable, nonporous surface which resists staining, can be surface or recessed mounted and features a stream regulator to adjust the water flow as needed. The Freeze Resistant Package allows the fountain to be installed on an interior heated wall, with a minimum temperature of 50° F (10° C) to prevent freezing in colder climates.

Halsey Taylor HRFG_SEBP_VR_FR is a non-refrigerated Marblyte VR, Freeze Resistant Fountain with Back Panel suitable for both indoor and outdoor use. This durable fountain, with an extremely durable, nonporous surface which resists staining, can be surface or recessed mounted and features a stream regulator to adjust the water flow as needed. The Freeze Resistant Package allows the fountain to be installed on an interior heated wall, with a minimum temperature of 50° F (10° C) to prevent freezing in colder climates.

98427C (Rev. B - 7/08)
HRFGSEBPVRFR*A
Non-refrigerated Marblyte VR, Freeze Resistant Fountain
with Back Panel
Halsey Taylor Owners Manual
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE
INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLA-
TION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE
CODES. After installation, leave these instructions inside the fountain for future reference.
This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s)
contains the Freeze Resistant Package(s) HTFRB1 that are installed on an interior
heated wall. The interior space must maintain a minimum temperature of 50° F (10° C).
Refer to the Freeze Resistant Package for the rough-in dimensions for installation.
Installer
FIG. 1
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
TUBE IS
SECURED
IN POSITION
SIMPLY PUSH IN
TUBE TO ATTACH
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
FIG. 2
OPERATION OF QUICK CONNECT FITTINGS
PAGE 1
98427C (Rev. B - 7/08)
HRFGSEBPVRFR*A
38 1/2"
978mm
18 3/4"
476mm
4"
102mm
4"
102mm
34 7/8"
886mm
5 1/8"
130mm
5 1/8"
130mm
28 7/8"
734mm
30 3/16"
767mm
3/16"
5mm
3 15/16"
100mm
C
C
D
B
B
FINISHED FLOOR
30 9/16"
777mm
3"
76mm
3"
76mm
36 9/16"
929mm
36 3/16"
920mm
A
A
5 3/16"
132mm
FIG. 3
PAGE 2
HRFG-SEBP-VR-FR
MOUNTING BOLT AND ACCESS HOLE LAYOUT
LEGEND:
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN
C = RECOMMENDED LOCATION FOR OPERATING CABLE 7/8" DIA HOLE
D = MOUNTING HOLES FOR SECURING FOUNTAIN TO WALL
(BLOCKING & WALL SUPPORT IS REQUIRED IN THESE AREA FOR PROPER SUPPORT OF FOUNTAINS)
98427C (Rev. B - 7/08)
HRFGSEBPVRFR*A
HRFG-SEBP-VR-FR
ROUGH-IN DRAWING
PAGE 3
FIG. 4
12 1/8"
307mm
12 1/8"
307mm
7 1/4"
184mm
7 1/4"
184mm
12"
305mm
MAX. WALL
THICKNESS
WASHER REQUIRED TO
MINIMIZE BREAKAGE
OF FOUNTAIN
(TYP.) ALL MOUNTING BOLTS
WASHERS NOT INCLUDED
DETAIL "A"
23 5/8"
600mm
33"
838mm
40 1/8"
1019mm
27"
686mm
ADA
REQUIREMENTS
7 1/8"
181mm
3"
77mm
13 11/16"
348mm
5 1/16"
128mm
1/2"
13mm
13 7/8"
353mm
18 3/16"
462mm
5 3/16"
132mm
5 3/16"
132mm
SEE DETAIL "A"
13 1/4"
337mm
14 1/4"
362mm
17 3/4"
451mm
19 1/4"
489mm
20 1/4"
514mm
23 3/4"
603mm
2 5/8"
66mm
3 5/8"
91mm
98427C (Rev. B - 7/08)
HRFGSEBPVRFR*A
PAGE 4
INSTALLATION INSTRUCTIONS
The freeze resistant package must be mounted on an interior wall in a heated area. The room temperature of the interior
heated area must be 50° F (10° C) or higher. The freeze resistant package may be surface or recessed mounted. If
recess mounted the surface of the cover must be flush with the interior wall surface. The package is furnished with
screws for mounting the cover to the box. If the box is recess mounted, do not fasten the top and bottom of the cover to
the box. Use the holes on the front only.
1. Assemble the operating cable to the fountain bracket. (Fountain should be mounted to exterior wall) Create a loop in
the cable and thread the free end of the cable through the wall into the freeze resistant box. The adjustment nuts should
be in the middle of threaded area on the operating cable. See Figure 9
2. Connect free end of operating cable to the valve-operating bracket. The end of the cables must be recessed into the
indents on the pivot brackets.
3. Remove cable free play by adjusting the jam nuts on the ends of the operating cable. See Figure 6
4. Connect water line from fountain bubbler into freeze resistant box. The connection to the box uses a quick connect
water fitting. Position the water line, in the fountain, to drain back into interior mounted box. Any water left standing, in
the exterior line, can freeze.
To insert tubing, push tube straight into fitting until it reaches a positive stop. To remove tubing from the fittings, relieve
water pressure, push in on dark gray collar while pulling out on the tubing. See Figure 2.
5. Connect drain and water supply lines to the freeze resistant fountain. Refer to Figure 3 or 4 for component positions.
Inline strainer must be used on the inlet water line.
Start-up
1. Turn on building water supply and check all connections for leaks. Repair as required.
2. Stream height is factory set at 35 PSI. If stream height needs to be changed adjust the regulator in the freeze resistant
package. Clockwise adjustment raises stream height, counter clockwise adjustment will lower stream.
3. Adjust operating cable as required. Cable system should have a minimal amount of free play to allow for proper valve
operation. If the system is too tight the valve will stay in the on position creating constant water flow. Too much free
play will result in non-operation of the valve with the push-buttons.
4. Note: Water from the drain back tube in the freeze resistant package, will continue to run while the valve is actuated.
5. After cable system is adjusted properly stuff flexible insulation into any openings between the outside wall and the
interior box.
6. Recheck all connections. If all connections are leak free replace cover(s) on the freeze resistant box(es) and fountain(s).
Care and Maintenance of Halsey Taylor Marblyte Fountains
Marblyte provides an exremely durable, nonporous surface which resists staining. Care is very simple.
Routine cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam cleaner, is all that is
normally needed to give many years of trouble free service. Cleaners left standing on the fountain surface
can dull the surface finish. Be certain to rinse all cleaning agents completely and polish with a soft cloth.
Harsh abrasive cleaners are not required and should not be used.
Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove simple
scratches and stains. Cigarette burns can normally be removed without noticeable effect. Deeper
scratches or gouges can be corrected with fine grit sandpaper (240 grit then 400 grit) or a green Scotchbrite
pad.
To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or like
products will keep the finish looking like new.
98427C (Rev. B - 7/08)
HRFGSEBPVRFR*A
PAGE 5
FIG. 9
FIG. 5
FIG. 6
See Fig. 6
See Fig. 5
FIG. 7
CABLE SHEATH ADJUSTMENT
To Increase Free Play
To Reduce Free Play
FIG. 8
23
22
98427C (Rev. B - 7/08)
HRFGSEBPVRFR*A
PAGE 6
BUBBLER - NIPPLE
3/8 - 18 LOCK NUT
BUBBLER
ANTI - ROTATION BALL
PUSH BUTTON
PUSH BUTTON EXTENSION
PUSH BUTTON GUIDE SLEEVE
#6-32 CAP SCREW
DRAIN FERREL
1 5/16 HEX NUT
BASIN BRACKET
PIVOT ROD
RETAINER
BUMPER
.125 SNAP BUSHING
BASIN PIVOT BRACKET
TAILPIPE GASKET
BOTTOM COVER PLATE - SHORT
BOTTOM COVER PLATE - LONG
GRANITE FTN SHORT
GRANITE FTN LONG
WASTE ARM ASSY
#10-24 PINNED TORX SCREW
POLY TUBING-CUT TO LENGTH
DOUBLE BACK PANEL
BIT - PINNED TORX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
NS
15028C
70012C
45392C
75575C
45662C
56117C
45738C
75672C
45391C
40045C
27945C
70854C
40206000
51667C
50198C
27946C
50074C
27201C
27658C
55969C
56053C
40628C
75534C
56092C
56301C
75520C
PART NO.ITEM NO.
PARTS LIST
DESCRIPTION
FIG. 10
3
4
2
BASIN
1
FIG. 11
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or
not regulate. Mineral deposits may be removed from the orifice with a small
round file not over 1/8" diameter or small diameter wire. CAUTION: DO NOT
file or cut orifice material.
Stream Regulator: If orifice is free of material deposits, regulate flow as in
Start Up Instructions on page 4 (Step 2). If replacement is necessary, see
parts list for correct regulator part number.
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-
free connectors which utilize an o-ring water seal. To remove tubing from the
fitting, relieve water pressure, push in on the gray collar while pulling on the
tubing.(See Figure 2, Page 1). To insert tubing, push tube straight into fitting
until it reaches a positive stop, approximately 3/4".
TROUBLE SHOOTING & MAINTENANCE
5
6
7
8
9
11
12
10
14
15
16
15
10
13
19
17
20
18
21
21
21
21
SEE FIG. 10
2222 CAMDEN COURT
OAK BROOK, IL 60523
630.574.3500
PRINTED IN U.S.A.
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR VISIT OUR WEBSITE WWW.HALSEYTAYLOR.COM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Halsey Taylor HRFG_SEBP_VR_FR Owner's manual

Type
Owner's manual

Halsey Taylor HRFG_SEBP_VR_FR is a non-refrigerated Marblyte VR, Freeze Resistant Fountain with Back Panel suitable for both indoor and outdoor use. This durable fountain, with an extremely durable, nonporous surface which resists staining, can be surface or recessed mounted and features a stream regulator to adjust the water flow as needed. The Freeze Resistant Package allows the fountain to be installed on an interior heated wall, with a minimum temperature of 50° F (10° C) to prevent freezing in colder climates.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI