Metrohm NIRS XDS RapidContent Owner's manual

Type
Owner's manual
NIRS XDS RapidContent Analyzer
Manual
8.921.8001EN / 2020-04-30
Metrohm AG
CH-9100 Herisau
Switzerland
Phone +41 71 353 85 85
Fax +41 71 353 89 01
www.metrohm.com
NIRS XDS RapidContent Analyzer
Manual
8.921.8001EN / 2020-04-30
Technical Communication
Metrohm AG
CH-9100 Herisau
This documentation is protected by copyright. All rights reserved.
This documentation has been prepared with great care. However, errors
can never be entirely ruled out. Please send comments regarding possible
errors to the address above.
■■■■■■■■■■■■■■■■■■■■■■
Table of contents
■■■■■■■■
III
Table of contents
1 Introduction 1
1.1 Instrument description ......................................................... 1
1.2 Intended use ......................................................................... 2
1.3 About the documentation ................................................... 2
1.3.1 Symbols and conventions ........................................................ 2
1.4 Safety instructions ................................................................ 3
1.4.1 General notes on safety ........................................................... 3
1.4.2 Electrical safety ........................................................................ 3
1.4.3 Flammable solvents and chemicals ........................................... 4
1.4.4 Recycling and disposal ............................................................. 4
2 Overview of the instrument 5
2.1 Monochromator .................................................................... 5
2.1.1 Connectors/rear ....................................................................... 5
2.1.2 Status display ........................................................................... 6
2.1.3 Instrument connection ............................................................. 6
3 Installation 7
3.1 Unpacking and inspecting the instrument ......................... 7
3.1.1 Packaging ................................................................................ 7
3.1.2 Checks .................................................................................... 7
3.1.3 Scope of application ................................................................ 7
3.2 Setting up the instrument .................................................... 7
3.2.1 Lifting and transporting instruments ........................................ 7
3.2.2 Ambient conditions ................................................................. 8
3.2.3 General conditions ................................................................... 8
3.2.4 Vibrations and/or shocks .......................................................... 8
3.3 Connecting monochromator to measuring module .......... 9
3.4 Connecting the power supply cable ................................. 10
3.5 Connecting the network cable .......................................... 11
3.6 Switching on the instrument ............................................. 11
3.7 Initial start-up ..................................................................... 12
3.8 Setting up accessories ........................................................ 12
4 Operation 13
5 Operation and maintenance 14
5.1 General notes ...................................................................... 14
5.1.1 Care ...................................................................................... 14
Table of contents
■■■■■■■■■■■■■■■■■■■■■■
IV
■■■■■■■■
5.1.2 Maintenance by Metrohm Service .......................................... 14
5.2 Maintenance ....................................................................... 14
5.2.1 Overview ............................................................................... 15
5.2.2 Replacing the fan filter ........................................................... 15
5.2.3 Replacing the lamp ................................................................ 18
5.2.4 Replacing the fuse ................................................................. 26
5.2.5 Cleaning the sampling window .............................................. 28
6 Appendix 30
6.1 Accessories for sample compartment ............................... 31
6.1.1 Sample cell ............................................................................ 31
6.1.2 Iris ......................................................................................... 32
6.2 Calibration standards ......................................................... 35
7 Technical specifications 36
7.1 LAN interface ...................................................................... 36
7.2 Power connection ............................................................... 36
7.3 Ambient conditions ............................................................ 36
7.4 Operation ............................................................................ 36
7.5 Reference conditions .......................................................... 37
7.6 Dimensions .......................................................................... 37
7.7 Housing ............................................................................... 38
8 Accessories 39
Glossary 40
Index 42
■■■■■■■■■■■■■■■■■■■■■■
Table of figures
■■■■■■■■
V
Table of figures
Figure 1 Front - measuring instrument ............................................................ 5
Figure 2 Rear - monochromator ...................................................................... 5
Figure 3 Status display .................................................................................... 6
Figure 4 Instrument connection ...................................................................... 6
Figure 5 On/off switch .................................................................................. 11
Figure 6 Mini sample cup with disposable back ............................................. 34
Figure 7 Vials ................................................................................................ 34
Figure 8 Transflection vessel with gold or stainless steel diffuse reflector ....... 34
■■■■■■■■■■■■■■■■■■■■■■
1 Introduction
■■■■■■■■
1
1 Introduction
This manual gives you a comprehensive overview of the installation and
maintenance of the NIRS XDS RapidContent Analyzer. The NIRS XDS Rap-
idContent Analyzer is operated with the control software. You can find
information on operating the instrument in the tutorial and in the manual
for the control software.
NOTICE
You can request application descriptions in the form of
Application Notes and Application Bulletins from your
Metrohm representative or download them from
http://www.metrohm.com.
1.1 Instrument description
The NIRS XDS RapidContent Analyzer is a measuring instrument for reflec-
tion measurement in the visible to near-infrared wavelength range.
The complete NIRS XDS RapidContent Analyzer measuring instrument
consists of two modules, monochromator and measuring module.
The monochromator operates in the range from 400 to 2,500 nm.
The measuring module to the NIRS XDS RapidContent Analyzer is
equipped with the corresponding accessories for specific samples and can
be replaced with other measuring modules during ongoing operation
(hot-swappable).
The NIRS XDS RapidContent Analyzer is designed for quality monitoring in
production processes and can be applied for the following purposes:
Quick and non-destructive incoming goods inspection of raw materials
Production process monitoring
Final inspection of finished products
The NIRS XDS RapidContent Analyzer can be used to measure the follow-
ing sample types:
Powders
Coarse solids/granulates
Solids/coatings/paper
Tablets/capsules
Turbid liquids
Pastes/creams
1.2 Intended use
■■■■■■■■■■■■■■■■■■■■■■
2
■■■■■■■■
Viscous liquids/gels
Clear liquids
The NIRS XDS RapidContent Analyzer is operated with the control soft-
ware via an external computer.
1.2 Intended use
The NIRS XDS RapidContent Analyzer is designed for use in production
facilities. It can be used for incoming goods inspection or for production
process monitoring.
This instrument is suitable for measuring chemicals and flammable sam-
ples. Usage of the NIRS XDS RapidContent Analyzer therefore requires the
user to have basic knowledge and experience in handling toxic and caustic
substances. Knowledge with respect to the application of the fire preven-
tion measures prescribed for laboratories is also mandatory.
1.3 About the documentation
CAUTION
Please read through this documentation carefully before putting the
instrument into operation. The documentation contains information
and warnings which the user must follow in order to ensure safe opera-
tion of the instrument.
1.3.1 Symbols and conventions
The following symbols and formatting may appear in this documentation:
Cross-reference to figure legend
The first number refers to the figure number, the sec-
ond to the instrument part in the figure.
Instruction step
Carry out these steps in the sequence shown.
Method Dialog text, parameter in the software
File New
Menu or menu item
[Next] Button or key
WARNING
This symbol draws attention to a possible life-threat-
ening hazard or risk of injury.
■■■■■■■■■■■■■■■■■■■■■■
1 Introduction
■■■■■■■■
3
WARNING
This symbol draws attention to a possible hazard due
to electrical current.
WARNING
This symbol draws attention to a possible hazard due
to heat or hot instrument parts.
WARNING
This symbol draws attention to a possible biological
hazard.
CAUTION
This symbol draws attention to possible damage to
instruments or instrument parts.
NOTE
This symbol highlights additional information and
tips.
1.4 Safety instructions
1.4.1 General notes on safety
WARNING
Operate this instrument only according to the information contained in
this documentation.
This instrument left the factory in a flawless state in terms of technical
safety. To maintain this state and ensure non-hazardous operation of the
instrument, the following instructions must be observed carefully.
1.4.2 Electrical safety
The electrical safety when working with the instrument is ensured as part
of the international standard IEC 61010.
WARNING
Only personnel qualified by Metrohm are authorized to carry out service
work on electronic components.
1.4 Safety instructions
■■■■■■■■■■■■■■■■■■■■■■
4
■■■■■■■■
WARNING
Never open the housing of the instrument. The instrument could be
damaged by this. There is also a risk of serious injury if live components
are touched.
There are no parts inside the housing which can be serviced or replaced
by the user.
Supply voltage
WARNING
An incorrect supply voltage can damage the instrument.
Only operate this instrument with a supply voltage specified for it (see
rear panel of the instrument).
1.4.3 Flammable solvents and chemicals
WARNING
All relevant safety measures are to be observed when working with
flammable solvents and chemicals.
Set up the instrument in a well-ventilated location (e.g. fume cup-
board).
Keep all sources of flame far from the workplace.
Clean up spilled liquids and solids immediately.
Follow the safety instructions of the chemical manufacturer.
1.4.4 Recycling and disposal
This product is covered by European Directive 2012/19/EU, WEEE – Waste
Electrical and Electronic Equipment.
The correct disposal of your old instrument will help to prevent negative
effects on the environment and public health.
More details about the disposal of your old instrument can be obtained
from your local authorities, from waste disposal companies or from your
local dealer.
■■■■■■■■■■■■■■■■■■■■■■
2 Overview of the instrument
■■■■■■■■
5
2 Overview of the instrument
Figure 1 Front - measuring instrument
1
Status display
2
Monochromator
3
Measuring module
2.1 Monochromator
2.1.1 Connectors/rear
Figure 2
Rear - monochromator
1
On/off switch
2
Fuse holder
2.1 Monochromator
■■■■■■■■■■■■■■■■■■■■■■
6
■■■■■■■■
3
Power socket
4
Covering
5
Fan
6
Network connection socket
2.1.2 Status display
Figure 3 Status display
1
Instrument on
2
Measurement ongoing
3
Connected to network
4
Lamp on
5
Monochromator connected to measur-
ing module
2.1.3 Instrument connection
The two modules are connected via mechanical, optical and electrical
interfaces, combining monochromator and measuring module to one
measuring instrument.
Figure 4
Instrument connection
1
Locking lever
2
Optical interface
3
Mechanical interface
4
Electrical interface
■■■■■■■■■■■■■■■■■■■■■■
3 Installation
■■■■■■■■
7
3 Installation
3.1 Unpacking and inspecting the instrument
3.1.1 Packaging
The instrument is supplied in protective packaging together with the sepa-
rately packed accessories. Keep this packaging, as only this ensures safe
transportation of the instrument.
3.1.2 Checks
Immediately after receipt, check whether the shipment has arrived com-
plete and without damage by comparing it with the delivery note.
3.1.3 Scope of application
The NIRS XDS RapidContent Analyzer is designed for offline use in the lab-
oratory or for monitoring production processes.
3.2 Setting up the instrument
Like most high-precision instruments, the NIRS XDS RapidContent Ana-
lyzer is sensitive to ambient conditions, which may negatively influence its
performance and shorten its service life. The following guidelines have to
be observed when the instrument is set up and put into operation:
3.2.1 Lifting and transporting instruments
WARNING
Heavy modular instruments
Incorrect handling when lifting and transporting can lead to injuries and
damages.
Instrument modules must be disconnected for moving and lifting
(see chapter 3.3, page 9).
Only lift or move heavy instruments with caution and/or the appro-
priate auxiliary tools.
Only transport heavy instruments on a trolley.
Put instruments down carefully to avoid damage to the optical-
mechanical elements.
3.2 Setting up the instrument
■■■■■■■■■■■■■■■■■■■■■■
8
■■■■■■■■
NOTICE
Dimensions and weights
The dimensions and weights are listed in the technical specifications
(see chapter 7.7, page 38).
3.2.2 Ambient conditions
The ambient conditions are decisive for a proper functioning and to
ensure accurate measured values. These conditions are listed in the techni-
cal specifications (see chapter 7.3, page 36).
High humidity and climatic fluctuations caused by unstable ambient condi-
tions hamper the instrument's stability in respect to calibration and mea-
suring accuracy.
NOTICE
Problems during calibration/measurement
If the expected values are not obtained during calibration and the test
runs, then you should check the ambient conditions.
Draft (air conditioning, open windows, etc.) and exposure to direct sun-
light should be prevented.
Make sure to allow enough free space (on the sides and the back at
least 75 mm) around the instrument to prevent heat accumulation.
3.2.3 General conditions
Dust and dirt may compromise the instrument's cooling and should there-
fore be prevented as far as possible.
The maintenance procedures for the fan filter are described as follows (see
chapter 5.2.2, page 15).
3.2.4 Vibrations and/or shocks
Vibrations and shocks interfere with the sensitive optical and mechanical
components and can compromise calibration and measuring accuracy.
Do not set up other instruments that cause vibrations and shocks (mills,
mixers, stirrers, etc.) on the same workplace as the NIRS XDS RapidCon-
tent Analyzer.
Set the instrument up on a stable workplace that does not pass on vibra-
tions (e.g. typing on keyboard).
■■■■■■■■■■■■■■■■■■■■■■
3 Installation
■■■■■■■■
9
3.3 Connecting monochromator to measuring module
CAUTION
Mechanical damage
Rough and careless handling may damage the connection elements.
Set the instrument up on a level workplace.
Align the instrument parts correctly before pushing them together.
Do not use excessive force.
Connecting monochromator to measuring module
1
Positioning the monochromator
Position the monochromator on the laboratory table in the shown
position.
2
Positioning measuring module and pushing together
Align the measuring module with the monochromator and push
together.
3.4 Connecting the power supply cable
■■■■■■■■■■■■■■■■■■■■■■
10
■■■■■■■■
3
Locking monochromator and measuring module
Push the locking lever down to connect the two instrument parts.
3.4 Connecting the power supply cable
The NIRS XDS RapidContent Analyzer instrument contains a permanently
installed power supply unit and can be directly connected to the power
supply with a power supply cable.
The power supply unit automatically supports operating voltages between
100 and 240 VAC at 50 / 60 Hz. The maximum power consumption is 750
watt.
■■■■■■■■■■■■■■■■■■■■■■
3 Installation
■■■■■■■■
11
3.5 Connecting the network cable
In order to control the NIRS XDS RapidContent Analyzer, it is connected to
a computer either directly or via a local network (LAN). Use the supplied
crossover network cable for connecting the instrument directly to a com-
puter's network card.
For a connection via your local network, you need a network cable.
As network configurations vary considerably across different companies, a
full discussion is not possible in this manual. We recommend that you
have your network specialist establish the connection between the instru-
ment and the company network.
NOTICE
Direct connection to computer
When directly connecting the measuring instrument to a computer, no
other network card for connection to a local network may be installed
at the same time.
This leads to communication errors and disruptions.
In network operation, connect the measuring instrument via the net-
work as well.
3.6 Switching on the instrument
Use the switch at the rear to switch on the instrument.
Figure 5
On/off switch
3.7 Initial start-up
■■■■■■■■■■■■■■■■■■■■■■
12
■■■■■■■■
3.7 Initial start-up
The initial start-up of the instrument is always carried out with the control
software.
You can find detailed information on the procedure in the tutorial for the
control software.
3.8 Setting up accessories
Metrohm offers a wide range of accessories for the NIRS XDS RapidCon-
tent Analyzer instrument.
A detailed description of how to use the accessories can be found in the
appendix (see chapter 6, page 30).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Metrohm NIRS XDS RapidContent Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI