User’s
Manual
Mounting and Connecting
TR and TS Hour Meters
Yokogawa Corporation of America
2 Dart Road Newnan, Georgia U.S.A. 30265
Tel: 1-800-258-2552 Fax: 1-770-254-0928
IM 61A00A-01E-A
©Copyright May 1, 2003
1st Edition 5/1/03 1M
TS Series (square face)
Select the mounting configuration from below to determine panel cutout size. Then see opposite page for
outline dimensions.
Model TS-xxxxAx (No bezel-use outline 1, if bezel ordered- use outline 2 or 3).
Model TS-xxxxCx (use outline for mounting option C).
Model TS-xxxxDx (no cutout required. This mounts on DIN rail).
Model TS-xxxxFx (use outline 1 only).
Model TS-xxxxGx (No bezel-use outline 1, if bezel ordered-use outline 2 or 3).
TR Series (round face)
Select mounting configuration below to determine panel cutout dimensions. Then see opposite page for
outline dimensions.
Model TR-xxxxAx (use outline for mounting option A).
Model TR-xxxxCx (use outline for mounting option C).
Model TR-xxxxHx (use outline for mounting option H)
Electrical Wiring
If you have selected combination terminals, or will use the screw terminals for connection, please
observe the following precautions:
1) Use AWG #20 to #26 stranded wire
2) Make sure wire is stripped back 3/8" and wire strands are twisted tight or soldered
3) Loosen non-captive screw no more than 5 full turns
4) Insert wire between pin and clip, then tighten securely,
If you are using the pin connection. Use a 1/4" quick connect female spade lug that has been properly
crimped to wire leads. Slide all the way onto the pin terminal.
Please observe polarity symbols molded into case above terminals.