6
● Use DRY operation when you want to reduce the humidity
in the room.
● Once the room temperature reaches the set level, the unit
repeats the cycle of turning on and off automatically.
● Dry operation is not possible if the indoor temperature is
16 °C or less.
NOTES
Verify that the unit is connected to the
main power.
1. Set the MODE selector to COOLING
mode (symbol on the display ).
2. Press the +/- buttons (temperature
selection) to set the desired temperature
(the temperature range is between 30 °C
max. and 16 °C min.).
HEATING
1. Set the MODE selector to HEATING mode (symbol on the
display ).
2. Press the +/- buttons (temperature selection) to set the
desired temperature (the temperature range is between 30
°C max. and 16 °C min.).
3. Press the FAN button to select the fan speed.
• For a few minutes after the start of heating operation,
the indoor fan doesn’t start until the indoor heat
exchanger coil has warmed up sufficiently. This is
because the COLD DRAFT PREVENTION SYSTEM
is operating. During this period, the STANDBY lamp
remains lit.
• During heating operation, when you switch off the unit
the fan goes on running for 10 seconds at low speed
in order to blow out residual heat air.
NOTES
DEFROSTING OF OUTDOOR HEAT
EXCHANGER
When the outdoor temperature is low, frost or ice may
appear on the heat exchanger coil, reducing the heating
performance. When this happens, a protection function
for the heat exchanger defrosting is activated. During this
function operation, the indoor fan stops. Heating operation
restarts after several minutes. (This interval will vary slightly
depending on the room and outdoor temperature).
COOLING
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
IF YOU WANT TO VISUALISE THE
ROOM TEMPERATURE, PRESS THE
TEMPERATURE BUTTON (HUMIDITY).
3. Press the FAN button to select the fan speed.
NOTE
AUTOMATIC OPERATION
1.
Set the MODE selector to DEHUMIDIFYING mode
(symbol on the display ).
2. Press the
+/- buttons (temperature selection)
to set the
desired temperature (the temperature range is between
30 °C max. and 16 °C min.).
DEHUMIDIFYING (DRY)
FAN ONLY
If you want to make air circulate without any temperature
control, press the MODE button until the fan symbol
appears on the display.
EN
BLOW
HUMIDITY
TIMER
LIGHT
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
IF YOU WANT TO VISUALISE THE
ROOM TEMPERATURE, PRESS THE
TEMPERATURE BUTTON (HUMIDITY).
During cooling operation, when the outside temperature is
very low, frost will appear on the surface of the indoor heat
exchanger. When the indoor heat exchanger temperature
drops below 0 °C for a continuous period of time, the unit
stops running.
NOTE
THE DISPLAY SHOWS THE
SELECTED TEMPERATURE.
IF YOU WANT TO VISUALISE THE
ROOM TEMPERATURE, PRESS THE
TEMPERATURE BUTTON (HUMIDITY).
1. With the unit off, set the MODE selector to AUTO mode
(symbol on the display)
.
The selection of the operation mode (cooling or
heating) is carried out automatically by the unit
according to the ambient temperature detected when
AUTO mode is selected.
2. If the ambient temperature is ≥ 26°C, selecting AUTO,
the unit starts to operate in cooling mode until it reaches
25°C (± 1°C). The default temperature for cooling (and
cannot be changed) is in fact 25°C; it appears on the
unit display, while nothing appears on the remote
control display.
3. If the ambient temperature is ≤ 20°C, selecting AUTO,
the unit starts to operate in heating mode until it reaches
22°C (±1°C). The default temperature for heating (and
cannot be changed) is in fact 20°C; it appears on the
unit display, while nothing appears on the remote
control display.
4. If the ambient temperature is between 23° and 25°C
(± 1°C), the unit will operate in fan only mode.