Soyal AR-401-IO-1709R Owner's manual

Type
Owner's manual
SOYAL
ACCESS CONTROL SYSTEM
®AR-401-IO-1709R
V220615
- 1 -
RX2TX2TX RXPWR
ON
1 1 1 1 1 1 1
222222222 111111111
22 22222333344445555
Relay
K30
Relay
K3
Relay
K1
Relay
K4
Relay
K6
Relay
K2
Relay
K5
Relay
K7
Relay
K8
CN1 CN2 CN5 CON11
CON3 CON4 CON5 CON6 CON7 CON8 CON9 CON10CON15
CON12 CON13 CON14
AR-401-IO-1709R
12 34 5678
117 mm
231 mm
103 mm
220 mm
135 mm
80 mm
180 mm
93 mm
Contents Features
1Product
Specication Installation(mm)
PIN Assignments
Digital Input can be used for either positive trigger or common negative trigger (share one COM point
for every 8 DI)
Built-in re alarm input, when access control is in use, automatically release open all linked electric lock to
ensure safety of personnel
RS485 communication, at the same time support Modbus RTU and SOYAL Protocol, suitable for both access
control system and industrial control
Provides a specialized rmware for dierent applciations, such as standard I/O control, multi-door interlocking,
and crowd counting rmware; in which can easily meets various applications
SCADA control function: Access Control SCADA (701Server/Client) with database system
supported.
Interface
Serial port
Baud Rate
Input/Output
Protocol
LED Indicator
Watchdog function
Operating Temperature
Fuses
Noise Isolation
Power Supply
Power Consumption
Dimension(mm)
Weight(g)
RS485 X 1 port
9600,19200 bps (N,8,1)
17 Digital Input/9 Relay Output (Form C)
Modbus, Soyal protocol
Power,Tx/Rx, D.O./D.I
Yes
-20 ~ +70
Power and RS485 Isolation protection
Input optical isolation
9-24 VDC
<4W
455±10(PCB Only)
PCB:120(H)x190(W)x20(D)
Panel Mounting Base :120(H)x220(W)x30(D)
CN1 CN2
Function
External Port 1
(RS-485 input)
Function
Fire Detection
Input
Pin
1
2
Pin
1
2
Description
A+
B-
Description
COM
DI-F
Function
Main Power Supply (Single
Power Supply Mode)
(DC12V/1W)
Pin
1
2
Description
V12
V0
Function
Relay output
K1~K8
Pin
1
2
Description
N.O.
or
N.C.
COM
CON3~10CN5
CON11
CON12
CON13
CON14
Function
Relay output K30
(Fire Detection Input)
Pin
1
2
Description
N.O. or N.C.
COM
Function
DI input
Function
DI input
Function
DI input
Function
DI input
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Pin
1
2
3
4
5
Description
DI.1
DI.2
DI.3
DI.4
COM
Description
DI.5
DI.6
DI.7
DI.8
COM
Description
DI.9
DI.10
DI.11
DI.12
COM
Description
DI.13
DI.14
DI.15
DI.16
COM
CON15
701ClientSQL Graphic Animation I/O mapping
starts from 00(Physical IO Address DI1 -->Symbol IO
Nr.:00, Physical IO Address DI16 -->Symbol IO Nr.:15)
(This version is compatible for hardware with serial number AQI06 and after)
(Metal Case) (Plastic Mounting Base)
V220615
- 2 -
RS485
CH1
Power
Fire
1
ON
23 45 67 8
K1
K30
K2
K3
K4
K5
K6
K7
K8
DI13~16
J11
DI9~12
DI5~8
DI1~4
X9
Relay
Sink Input
POWER
Source Input
COM
J10
POWER
or
N.C.
N.O.
DI.4
DI.3
DI.2
DI.1
COM
DI.8
DI.7
DI.6
DI.5
COM
DI.12
COM
DI.11
DI.10
DI.9
DI.16
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
N.O./N.C.
COM
DI.15
DI.14
DI.13
Vin-
Vin+
COM
DI-F
A+
B-
17-CH Optical Coupling DI /
9-CH Relay Output Module
Wiring Diagram
Standard Firmware--DIP Switch Setting
8 Interlock Door Solution--DIP Switch Setting
Use binary to calculate Node Number
Use binary to calculate Node Number
Door lock output relay time
Alarm output relay time
3 seconds
3 seconds
6 seconds
6 seconds
9 seconds
9 seconds
15 seconds
Latch
L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8H L 1 2 3 4 5 6 7 8H L 1 2 3 4 5 6 7 8 HL 1 2 3 4 5 6 7 8 H
N.O. N.C.
ON ON ON ONON ON ON
BAUD19200BAUD9600 N.C./N.O. Type witch
L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8H
L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8 H
L 1 2 3 4 5 6 7 8 H
ON ON ON ON
ON ON ON ON
ON ON ON
Com negative trigger
(COM is 0V)
Positive trigger
(9-24VDC)
Input Mode Setting Wiring Method
Node ID (# 1~127)
Example : Node 1 Example : Node 2 Example : Node 64
Node ID (Range 1~64; 000 equivalent to Node ID 64)
Example: Node 1 Example:Node 2 Example : Node 16
Node ID (# 1~16)
Com negative trigger (COM is 0V)
Positive trigger (9-24VDC)
Input Mode Setting(J10/J11):
Example
Sink
Input
Sink Input(Default):
Source Input :
D1 Group Adjusted Inputsetting
DI 1~4 J10
DI 5~8 J10
DI 9~12 J11
DI 13~16 J11
Example
Source
Input
  • Page 1 1
  • Page 2 2

Soyal AR-401-IO-1709R Owner's manual