Ideal Split-Jaw™ Smart Meter Operating instructions

Category
Multimeters
Type
Operating instructions

This manual is also suitable for

1 2
#61-096
200A~
61-096
CAT. IV
600V~
VA
H
Lo ZI
Ω
AUTO SEL
AC
DC
HOLD
VOLTS: 0-750VAC
0-1000VDC
AMPS: 0-200AAC
OHMS: 0-2000
Continuity
Split-Jaw
Smart-Meter
Ω
COM
CAT. IV
600V
CAT. III
1000V
V-Ω
Split-Jaw™
Smart-Meter
Register your product and
access more information at
www.idealindustries.com
Read First: Safety
Information
Understand and follow operating
instructions carefully. Use the meter,
test leads and all accessories only
as specified in this manual;
otherwise, the protection provided
by the meter can be impaired.
WARNING
To avoid possible electric
shock, personal injury or death,
follow these guidelines:
• Donotuseifmeterappearsdamaged.Visuallyinspectthe
meter to ensure case and jaws are not cracked.
• Inspectandreplacetestleadsifinsulationisdamaged,
metal is exposed, or probes are cracked. Pay particular
attention to the insulation surrounding the connectors.
• Alwaysensurethemeter,testleadsandallaccessories
meet or exceed the measurement category required in the
workingenvironment.(i.e.CATrating)
• Notethatthemeasurementcategoryandvoltagerating
of combinations of the meter, the test leads, and the
accessories is the lowest of the individual components.
• Donotusemeterifitoperatesabnormallyasprotection
maybe impaired.
•
Donotuseduringelectricalstormsorinwetweather.
• Donotusearoundexplosivegas,dust,vapor,amperage
or in damp or wet environments.
•
Donotapplymorethantheratedvoltagetothemeter.
• Removethetestleadsfromtheinputjacksbefore
measuring current.
• Replacebatteryassoonasbatteryindicatorappears
to avoid false readings.
• Removethetestleadsfromthemeterpriortoremoving
battery cover.
• Donotusewithoutthebatteryandbatterycoverproperly
installed.
• Donotattempttorepairthisunitasithasnouser-
serviceable parts.
• Usetheproperterminals,functionsandrangeforyour
measurements.
•
Nevergroundyourselfwhentakingelectricalmeasurements.
• Connecttheblackcommonleadtogroundorneutral
before applying the red test lead to potential voltage.
Disconnecttheredtestleadfromthevoltagefirst.
• Keepfingersbehindtheguardringsoftheprobetips.
• Holdtheclampbehindthetactilebarrier.
• Voltagesexceeding30VACor60VDCposeashock
hazard so use caution.
CAUTION
Toprotectyourself,think“SafetyFirst”:
• Complywithlocalandnationalsafetycodes.
• Useappropriatepersonalprotectiveequipmentsuchas
face shields, insulating gloves, insulating boots, and/or
insulating mats.
• Beforeeachuse:
- Performacontinuitytestbytouchingthetestleads
together to verify the functionality of the battery and
test leads.
- Usethe3PointSafetyMethod.(1)Verifymeter
operationbymeasuringaknownvoltage.(2)Apply
metertocircuitundertest.(3)Returntotheknown
live voltage again to ensure proper operation.
• Alwaysworkwithapartner.
~
...
Symbols on the Unit
Test Leads
RiskofDanger.ImportantInformation.See
Manual.
Hazardousvoltage.Riskofelectricalshock.
Applicationaroundandremovalfrom
HazardousLiveconductorsispermitted.
AC(AlternatingCurrent)
DC(DirectCurrent)
Earth Ground
CAT II
MeasurementCategoryIIappliestotestand
measuring circuits connected directly to
utilization points (socket outlets and similar
points)ofthelow-voltageinstallation
CAT III
MeasurementCategoryIIIappliestomea-
suring circuits connected to the distribution
partofthebuilding’slow-voltageinstallation
CAT IV
MeasurementCategoryIVappliesto
test and measuring circuits connected at
thesourceofthebuilding’slow-voltage
installation
Guard ring
3 4
Power On / Off
Auto Power Off
Voltage AC/DC
ACV Measuring Range:
1.3V - 750.0V
CAUTION
Ifthemeterisusedinthevicinityofequipmentwhich
generates electromagnetic interference, the display may
become unstable or the measurements shown may be
subject to large errors.
Onġ
Offġ
Offġ Onġ
HOLD
HOLD
HOLD
Ω
AUTO SEL
Press
Ω
AUTO SEL
HOLD
HOLD
HOLD
Press > 2sec
V
AC
AUTO SEL
30 min
HOLD HOLD
Onġ
Offġ
Offġ Onġ
HOLD
HOLD
HOLD
Ω
AUTO SEL
Press
Ω
AUTO SEL
HOLD
HOLD
HOLD
Press > 2sec
COM
V-Ω
AUTOMATIC
TESTER
HOLD
V
AC
200A~
ACV < 1.0V
CAT. IV
600V~
AUTO SEL
AUTO SEL
V
AC
Voltage AC/DC
Resistance (Ohms)
DCV Measuring Range:
1.8V - 1000V
0.6V~ - 1000V
• Input Impedance
> 4Kforinputvoltageupto30V.Impedanceincreasewith
inputvoltagetoapproximately200KΩat600V.
Warning
Donotapplymorethan1000VDC/750VACbetweenTester
terminal and earth ground
COM
V-Ω
AUTOMATIC
TESTER
HOLD
V
AC
200A~
ACV < 1.0V
CAT. IV
600V~
AUTO SEL
AUTO SEL
V
AC
200A~
AUTO SEL
HOLD
CAT. IV
600V~
COM V-Ω
AUTOMATIC
TESTER
Ω
Ω
MeasuringRange:
0Ω~2.000Ω
5 6
Continuity
(
))))
)
AC Current (Amps)
Jawacceptsupto1/0cable(cu)(0.5”or12.7mmmax.
diameter)
200A~
CAT. IV
600V~
< 25 Ω
HOLD
AUTOMATIC
TESTER
COM
V-Ω
Ω
AUTO SEL
Ω
AUTO SEL
> 400 Ω
MeasuringRange:
0.6A~200A
BarrierforHandGuardBarrierforHandGuard
CATIV600V
with respect to earth
for the jaw.
Donotholdthe
meter across the barrier.
20
0A
AUTO SEL
COM
CAT. IV
600V
CAT. III
1000V
V-Ω
ġ
I
I
OK
OK
OK
(I) + (–I) = 0
Current Cancel
Data Hold
Battery Replacement
Maintenance
DonotattempttorepairthisTester.Itcontainsnouser
serviceable parts. Repair or servicing should only be
performed by qualified personnel.
Cleaning
Periodicallywipethecasewithadryclothanddetergent.Do
not use abrasives or solvents.
Priority of Function
1
00A
200A~
CAT. IV
600V~
200A~
CAT. IV
600V~
HOLD HOLD
HOLD
AUTOMATIC
TESTER
AUTOMATIC
TESTER
A
AUTO SEL
Press
AC
A
AUTO SEL
AC
H
A
AUTO SEL
AC
H
H
A
AUTO SEL
AC
TheLCDdisplayshowsvoltage
modewhentheInputTerminal
satisesthefollowingconditions:
ACV
1.3 V ~ 750 V
DCV
1.8 V ~ 1000 V
–0.6 V ~ -1000 V
TheLCDdisplayshowsΩ mode
whentheInputTerminalsatises
thefollowingconditions:
0 ~ Ω
ACV
0 ~ 0,9 V
DCV
–0.2 ~ –0.02 V
DCV
0.2 ~ 1.4 V
TheLCDdisplayshowsACA
modewhentheCurrentInput
Jaw satisfies the following
conditions:
ACA 0.6 A ~ 200 A
1st: ACV DCV
2nd:
3rd: ACA
ACA
Ω
ACV, DCV
Whichever is
greater
Ω
A
AUTO SEL
AC
7 8
Specifications
1-1 General Specifications
Jaw opening:0.5”(12.7mm)Acceptsupto1/0copper
cable.
LCD display digits:6000digitlargescaleLCDreadout.
Measuring rate:5times/sec.
Overrange display:“OL”isdisplayedforΩ”function,
showstherealvaluefor“A”and“V”function.
Automatic power off time:Approximately30minutes
after power on.
Low battery indicator: is displayed. Replace the
battery when the indicator appears in the display.
Power requirement: 9Vbattery
Battery type and life: ALKALINEPP3,9V250hours
1-2 Environmental Conditions
Indoor Use.
Calibration: Oneyearcalibrationcycle.
Operating temperature:0°C~30°C(
<
80%RH)
30°C~40°C(
<
75%RH)
40°C~50°C(
<
45%RH)
Storage temperature: -20to+60°C,0to80%RH
(batteriesnotfitted)
Operating altitude:2000m(6562ft)
Overvoltage category:
IEC61010-1 CATIV600V
CATIII1000V
IEC61010-1 CATIV600V
CATIVequipmentofOVERVOLTAGECATEGORYIVisforuseat
theoriginoftheinstallations.Noteexamplesincludeelectricity
metersandprimaryover-currentprotectionequipment.
Conductor Size:27mmdiameter
Pollution degree: 2
EMC:EN61326-1
Shock vibration:SinusoidalvibrationperMIL-T-
28800E(5~55Hz,3gmaximum)
Drop Protection:
4 foot drop to hardwood on concrete floor
1 - 3 Electrical Specifications
Accuracyis±(%reading+numberofdigits)at23°C±5°C
<80%RH.
Temperature coefficient:
0.2x(Specifiedaccuracy)/°C,<18°C,>28°C.
Voltage
Function Range Accuracy
V~ 1.3~750.0V
±(1.5%+3dgt)
50Hz~500Hz
V
1.8V~1000V ±(1%+2dgt)
-0.6V~-1000V ±(1%+4dgt)
Overload protection: 1000VDC/750VAC
Max Operation time: DT=30sfor
30V
Input impedance:
4Kforinputvoltageupto30V.
Impedanceincreaseswithinputvoltagetoapproximately
200KΩat600V.
...
Resistance & Continuity
Function Range Accuracy
Ω
))))
0.0Ω~99.9Ω ±(2%+1Ω)
100Ω~2000Ω
±(2%+2dgt)*
*Temperaturecoefficientmultipliesby1.5whenoperating
temperatureis40°C~50°C.
Overload protection: 1000VDC/750VAC
Max. open circuit voltage: 1.5V
Continuity check: Internalbeeperactivatesiftheresistance
ofthecircuitundertestislessthan25Ω.Itwillthenturnoff
iftheresistanceisincreasedbeyond400Ω.
AC Current
Function Range Accuracy
A~ 0.6A~200.0A
±(1.8%+3dgt)*
50Hz~60Hz
Overload protection: 400A
±(1.8%+6dgt)for
<
50A.
Max. open circuit voltage: 1.5V
Continuity check: Internalbeeperactivatesiftheresistance
ofthecircuitundertestislessthan25Ω.Itwillthenturnoff
iftheresistanceisincreasedbeyond400Ω.
Warranty Statement
Thistesteriswarrantedtotheoriginalpurchaseragainst
defects in material and workmanship for two years from
thedateofpurchase.Duringthiswarrantyperiod,IDEAL
INDUSTRIES,INC.will,atitsoption,replaceorrepairthe
defective unit, subject to verification of the defect or
malfunction.
Thiswarrantydoesnotcoverfuses,batteriesordamage
from abuse, neglect, accident, unauthorized repair, alteration,
or unreasonable use of the instrument.
AnyimpliedwarrantiesarisingoutofthesaleofanIDEAL
product, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are
limitedtotheabove.Themanufacturershallnotbeliable
for loss of use of the instrument or other incidental or
consequential damages, expenses, or economic loss, or for
any claim or claims for such damage, expenses or economic
loss.
Statelawsvary,sotheabovelimitationsorexclusionsmay
notapplytoyou.Thiswarrantygivesyouspecificlegal
rights, and you may also have other rights which vary from
state to state.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Ideal Split-Jaw™ Smart Meter Operating instructions

Category
Multimeters
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI