Symmons SLC-9612-1.5 Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

Origins
-0.5 0.5 gpm (1.9 L/min) aerator
-1.0 1.0 gpm (3.8 L/min) aerator
-G Grid drain
-STN Satin Nickel finish
Model Numbers
Two Handle Centerset Lavatory Faucet
Operation & Maintenance Manual
SLC-9610-1.5, SLC-9612-1.5
Two handle centerset lavatory faucet featuring a
4” mounting conguration. Includes ceramic cartridges,
1/2” IPS inlet connections, 50/50 drain assembly and
standard 1.5 gpm (5.7 L/min) aerator. Components made
from brass and nonmetallic materials plated in standard
polished chrome nish.
Specification
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Compliance
c
Certied by
IAPMO R&T
Dimensions
Note: Dimensions subject to change without notice.
Modifications
Note: Append appropriate -sufx to model number.
SLC-9610-1.5
Origins Two Handle Centerset Lavatory Faucet
Less Rod
SLC-9612-1.5
Origins Two Handle Centerset Lavatory Faucet
-NSF/ANSI 372, NSF/ANSI 61.9
-ASME A112.18.1/CSA B125.1
-WaterSense 1.5 gpm (5.7 L/min)
Measurements
A 8 7/8”, 225 mm
B 6”, 152 mm
C 4”, 102 mm
D 3 3/4”, 95 mm
E
Deck Thickness Ref.
Max. 1 1/4”, 32 mm
F
Hole Size
Min. Ø 1”, 25 mm
Max. Ø 1 1/8”, 29 mm
G
(2x) Hole Size
Min. Ø 1 1/8”, 29 mm
Max. Ø 1 1/4”, 32 mm
H 3 1/8”, 79 mm
I 1 5/8”, 41 mm
J 4 1/4”, 108 mm
K 1 3/4”, 44 mm
L 1/2-14 NPSM
CC
DD
EE
JJ
KK
GG
BB
AA
FF
HH
II
LL
For California Residents
WARNING: This product contains chemicals known to
the State of California to cause cancer, birth defects, or
other reproductive harm.
2
*Note: Append -STN to part number for Satin Nickel
nish.
Replacement Parts
Item Description Part Number
A Lift Rod RL-219*
B
D
(2x) Handle Kit RL-220*
E Hot Cartridge RL-222H
F Cold Cartridge RL-222C
H Aerator
RL-240-1.5* (1.5)
RL-240-1.0* (1.0)
RL-240-0.5* (0.5)
I
J
Mounting Hardware RL-221
K 50/50 Drain Assembly
RL-223*
(SLC-9612-1.5)
L Grid Drain
P-26*
(SLC-9610-1.5)
Tools Required
Adjustable wrench
Allen wrench (3/32”)
Plumber putty
Plumber tape
PLUMBER
PUTTY
Parts Breakdown
K1
K2
K3
K8
K14
K4
K5
K6
K7
K9
K10
K13
K11
K12
B
K
D
C
E
F
G
H
I
J
A
L
3
G
I
2) Install mounting nuts (J) onto
1/2” IPS inlet connections on
faucet body (G). Using a wrench,
nish with one-half turn. DO NOT
overtighten.
1
1
1
G
J
If replacing an older faucet
ensure water supply is turned
OFF before removing, then
turn faucet control valve ON to
relieve water pressure.
1) Insert faucet body (G) through
mounting gasket (I) and sink
holes.
3) Seat ange (K2) into sink (K3 gas-
ket optional). Install gasket (K4),
washer (K5) and nut (K6) onto
ange (K2) from below sink, but
do not secure nut. Screw on tail
piece (K7) and hand tighten.
2
3
K2
K7
PLUMBER
PUTTY
OPTIONAL
K3
K4
K5
K6
4) Turn tail piece (K7) and ange
(K2) so pivot is facing toward
faucet. Pull assembly down into
drain hole. Secure hardware from
below sink. Install stopper (K1) in
the removable or non-removable
position.
2
3
K7
PIVOT
K2
K1
5) Attach inner washer (K8), pivot rod
(K9) and outer washer (K10) to tail-
piece (K7). Hand tighten nut (K11)
to secure pivot rod (K9).
K9
K7
1
K8
K10
K11
2
6) Connect lift rod (A) to clevis strap
(K13) and secure with thumb
screw (K14). Insert pivot rod
(K9) through spring clip (K12)
and clevis strap (K13). Secure
with spring clip (K12) and adjust
linkage if necessary.
3
4
4
K12
K9
K13
2
K14
K13
1
A
Installation
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2016 Symmons Industries, Inc. www.symmons.com [email protected] ZV-3119 REV C 022416
Troubleshooting Chart
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
7) Attach supply lines to 1/2” IPS inlet
connections on faucet body (G).
Using a wrench, nish with one half
turn. DO NOT overtighten.
Maintenance
1) Turn off water. Loosen and
remove handle set screw (D),
handle (B), nut (C) and old
cartridge (E or F).
6
5
3
4
1
2
B
C
D
F
2) Correctly align new cartridge (E
or F) and insert into faucet body
(G). Install and secure nut (C).
1
2
3
C
F
G
3) Replace handle (B) and reinstall set
screw (D). Tighten set screw.
G
8) Attach supply lines to shut-off
valves and hand tighten. Using a
wrench, nish with one-half turn.
DO NOT overtighten.
1
1
2
9) Remove aerator (H) and ush
lines free of debris. Check for
leaks.
2
Installation
H
1
1
3
2
B
D
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Symmons SLC-9612-1.5 Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI