GENERAL DESCRIPTION
This unique tester has been designed
specifically for testing the BreakGlass
detector.
By simulating the sound of breaking
glass the Breakglass Tester offers
a way of correcting the sensitivity
of the Breakglass detector ensuring
good detection and performance
at all times.
RINS 301-4
This product is approved for use in the
Residential, Commercial and Light Industrial Environment.
OPERATIONAL SWITCHES
OFF - Tester switched off.
NORMAL - Press the trigger when in normal mode to
Generate a loud breaking glass sound.
FLEX - In Flex mode, pressing the trigger arms the unit.
To create a flex condition thump the protected
glass in a controlled manner.
This will cause the Breakglass Tester to
generate a breaking glass sound.
TRIGGER - Creates glass break sound.
TEST PROCEDURE
Step 1 - Take the cover off the detector and place in test mode.
Step 2 - Set sensitivity to minimum.
Step 3 - Place the tester next to the window, which is to be protected.
Step 4 - Switch the tester into flex mode.
Step 5 - Arm the tester by pressing the trigger button.
Step 6 - Thump the glass lightly to simulate object hitting the window.
Step 7 - When the Tester simulates breaking glass check all the LED
indicators on the Breakglass detector.
The indicators will illuminate in the following order indicating
a good activation. (Green, Orange and Red)
Step 8 - Adjust the sensitivity as required to gain the best LED indication.
(After sensitivity adjustment re-test)
Step 9 - Replace cover on detector.
Step 10 -Note See Breakglass instructions for further
information on detector.
LOUD NOISE
SAFETY
The Breakglass tester produces loud sounds, always direct the tester away from the ear
when in use.
SPECIFICATIONS
Operating Voltage - 9V Battery
Battery Life - 2000+ Operations
Simulated Glass - Plate glass
Operating Temperature -10 C to 40 C
Storage Temperature -20 C to 60 C
STEP 1
Sensitivity adjustment
Min
Max
STEP 2
STEP 7
GREEN = Flex activation.
ORANGE = Shatter activation.
RED = Alarm Activation
LED Indicators
BREAKGLASS
2000
Tester
TRIGGER
FLEX
NORMAL
OFF
TM
LOUD NOISE
TRIGGER
FLEX
NORMAL
OFF
100mm
190mm
35 mm
WARRANTY
This product is sold subject to our standard warranty
conditions and is warranted against defects in workmanship for
a period of 2 years. In the interest of continuing improvement
of quality, customer care and design Pyronix LTD reserve
the right to amend specifications without giving
prior notice.
Pyronix Limited
Pyronix House
Braithwell Way
Hellaby, Rotherham
S66 8QY, ENGLAND
Tel: 0845 6434 999
or +44(0)1709 535225
Hours: Monday to Friday, 8:00am - 6:30pm
email: customer.[email protected]
website: www.pyronix.com
  • Page 1 1
  • Page 2 2

Pyronix BREAKGLASS 2000 Quick start guide

Type
Quick start guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI