Marantec USV Owner's manual

Category
Uninterruptible power supplies (UPSs)
Type
Owner's manual

Marantec USV

Below you will find brief product information for Marantec USV battery management systems. These systems are designed to provide backup power to compatible Marantec drives and control systems in dry areas. They can be used to power equipment that does not exceed the manufacturer's given maximum values.

The USV systems are available in various sizes and power ratings, making them suitable for a wide range of applications. The 750 VA system is ideal for small systems, while the 1000 - 1500 VA systems are suitable for medium-sized systems. The 5000 - 7500 VA systems are designed for large systems with high power demands.

Marantec USV

Below you will find brief product information for Marantec USV battery management systems. These systems are designed to provide backup power to compatible Marantec drives and control systems in dry areas. They can be used to power equipment that does not exceed the manufacturer's given maximum values.

The USV systems are available in various sizes and power ratings, making them suitable for a wide range of applications. The 750 VA system is ideal for small systems, while the 1000 - 1500 VA systems are suitable for medium-sized systems. The 5000 - 7500 VA systems are designed for large systems with high power demands.

Product description battery management system UPS
EN
Product description battery management system UPS / Rev.A 0.0 – 1
2 – Product description battery management system UPS / Rev.A 0.0
1. General
1.1 Document information
The UPS battery management systems are to be exclusively
used for the control of compatible Marantec drives and
control systems in dry areas.
The UPS battery management systems may only be used to
power equipment that do not exceed the manufacturer’s
given maximum values.
The installer and the user must ensure that all applicable
legal and ofcial requirements regarding the use of the
products, in particular the current EMC guideline concerning
installation and operation, are observed.
1.2 Installation
Information:
The mains cable must not be exchanged with the output
cable.
The neutral conductor (N) and the outer conductor (L)
on the input side must not be connected to the neutral con-
ductor (N) and the outer conductor (L) on the output side.
The cable for the door control must always be 3-wire or
5-wire at 1x230 or 3x400V.
Connection:
Plug the supply line (A) into the socket of the on-site power
supply.
Plug the control system’s supply line into the appropriate
socket (B)
Switch the battery management system to the ON position
with the key switch (C)
Fix the casing with plugs and screws in the desired position.
The mounting holes are located in the back wall of the
cabinet.
Meaning of signals and buttons:
BAT / POWER = battery OK
ON = battery management system is switched on
UPS = battery operation mode (power failure)
ON = switch on
OFF = switch off
REFERENCE
All technical data can be found in the separate data sheets.
EN
Product description battery management system UPS / Rev.A 0.0 – 3
1.3 UPS circuit diagram
UPS input
UPS output
L or L1-3 L or L1-3
Input
UPS logic module
Output
N N
PE PE
4 – Product description battery management system UPS / Rev.A 0.0
2.1 UPS 750 VA
CAUTION!
As soon as the battery management system is connected
to a power supply, it will also feed power. This also applies
when the battery management system is switched off!
A
BC
Please connect the battery management system to a 230 V /
1~ power supply.
Switch the battery management system on. The two LEDs
“BAT” = orange and “ON” = green should now light up.
If no power supply is connected, the battery management
system automatically switches to UPS mode. This is indicated
by the “UPS” LED = red additionally lighting up.
In order to switch off the battery management system, turn
the key switch to the OFF position. All LEDs will go out.
CAUTION!
The batteries also feed power after the mains plug has
been removed!
2. Product overview
EN
Product description battery management system UPS / Rev.A 0.0 – 5
Please connect the battery management system to a 400 V /
3~ power supply.
Switch the battery management system on. The two LEDs
“BAT” = orange and “ON” = green should now light up.
If no power supply is connected, the battery management
system automatically switches to UPS mode. This is indicated
by the “UPS” LED = red additionally lighting up.
In order to switch off the battery management system, turn
the key switch to the OFF position. All LEDs will go out.
CAUTION!
The batteries also feed power after the mains plug has
been removed!
2.2 UPS 1000 - 1500 VA
CAUTION!
As soon as the battery management system is connected
to a power supply, it will also feed power. This also applies
when the battery management system is switched off!
A
B C
6 – Product description battery management system UPS / Rev.A 0.0
2.3 UPS 5000 - 7500 VA
CAUTION!
As soon as the battery management system is connected
to a power supply, it will also feed power. This also applies
when the battery management system is switched off!
A B
C
Please connect the battery management system to a 400 V /
3~ power supply.
Switch the battery management system on by turning the
key switch to the ON position and holding it there for a few
seconds. The two LEDs “POWER” = blue and “ON” = green
should now light up.
If no power supply is connected, the battery management sys-
tem automatically switches to UPS mode. This takes approx.
5 seconds and is indicated by the LED “ON” = green and
“UPS” = red lighting up.
In order to switch off the battery management system, turn
the key switch to the OFF position and hold it there until all
LEDs go out.
CAUTION!
The batteries also feed power after the mains plug has
been removed!
EN
Product description battery management system UPS / Rev.A 0.0 – 7
Type:
UPS
750 VA
UPS
1000 VA
UPS
1500 VA
UPS
5000 VA
UPS
7500 VA
Output (VA): 750 1000 1500 5000 7500
Input
Phases: 1 (L1, N, PE) 3 (L1, L2, L3,
N, PE)
3 (L1, L2, L3,
N, PE)
3 (L1, L2, L3,
N, PE)
3 (L1, L2, L3,
N, PE)
Rated voltage (V): 230 400 400 400 400
Voltage range: ± 10% ± 10% ± 10% ± 10% ± 10%
Frequency range (Hz): 50 50 50 50 50
Output
Rated voltage (V): 230 400 400 400 400
Voltage range: ± 10% ± 10% ± 10% ± 10% ± 10%
Apparent power (VA): 750 1000 1500 5000 7500
Static voltage stability: ± 10% ± 10% ± 10% ± 10% ± 10%
Frequency range (Hz): 50 50 50 50 50
Weight (kg): 15 22 24 145 160
Size (cm): 235 x 580 x
110
440 x 690 x
180
440 x 690 x
180
620 x 1200
x 170
620 x 1200
x 280
Noise emission (dBA (1m)): 54 54 54 54 54
Operating temperature (°C): +1 / +27 +1 / +27 +1 / +27 +1 / +27 +1 / +27
Relative humidity: < 95%
non-condens-
ing
< 95%
non-condens-
ing
< 95%
non-condens-
ing
< 95%
non-condens-
ing
< 95%
non-condens-
ing
Protection class (IP) 40 40 40 40 40
3. Technical data
#163250
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Marantec USV Owner's manual

Category
Uninterruptible power supplies (UPSs)
Type
Owner's manual

Marantec USV

Below you will find brief product information for Marantec USV battery management systems. These systems are designed to provide backup power to compatible Marantec drives and control systems in dry areas. They can be used to power equipment that does not exceed the manufacturer's given maximum values.

The USV systems are available in various sizes and power ratings, making them suitable for a wide range of applications. The 750 VA system is ideal for small systems, while the 1000 - 1500 VA systems are suitable for medium-sized systems. The 5000 - 7500 VA systems are designed for large systems with high power demands.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI