HQ Power VDP150CC6 User manual

Category
Stroboscopes & disco lights
Type
User manual
VDP150CC6_v2 HQ POWER
3
VDP150CC6 – 6-CHANNEL ARCHITECTURAL LIGHTING 150W
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized
company for recycling.
This device should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for buying the VDP150CC6! Please read the manual thoroughly before bringing this device into service.
If the device was damaged in transit, don't install or use it and contact your dealer.
2. Safety Instructions
Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer
will not accept responsibility for any ensuing defects or problems.
A qualified technician should install and service this device.
Do not switch the device on immediately after it has been exposed to changes in temperature. Protect the device
against damage by leaving it switched off until it has reached room temperature.
This device falls under protection class I. It is therefore essential that the device be earthed. Have a qualified
person carry out the electric connection.
Make sure that the available voltage does not exceed the voltage stated in the specifications of this manual.
Do not crimp the power cord and protect it against damage. Have an authorized dealer replace it if necessary.
Disconnect the device from the mains to clean it or when it is not in use. Handle the power cord by the plug only.
There may be some smoke or a particular smell when the device is activated for the first time. This is normal and
any smoke or smell will gradually disappear.
Do not look directly at the light source as sensitive people may go into epileptic seizure if they do.
Note that damage caused by user modifications to the device is not covered by the warranty.
Keep the device away from children and unauthorized users.
3. General Guidelines
This device is designed for professional use on stage, in discos, theatres, etc. The VDP150CC6 can be used
indoors and outdoors with an alternating current of max. 230VAC / 50Hz.
Lighting effects are not designed for permanent operation: regular operation breaks will prolong their lives.
Do not shake the device. Avoid brute force when installing or operating the device.
Select a location where the device is protected against extreme heat (see “Technical Specifications”), dust and
moisture. Respect a minimum distance of 0.5m between the device’s light output and any illuminated surface.
Use an appropriate safety cable to fix the device (e.g. VDLSC7 or VDLSC8).
Familiarize yourself with the functions of the device before actually using it. Do not allow operation by unqualified
people. Any damage that may occur will most probably be due to unprofessional use of the device.
Be very careful during the installation: touching live wires can cause life-threatening electroshocks.
Do not touch the device during operation as the housing heats up.
Unplug the mains lead before opening the housing.
VDP150CC6_v2 HQ POWER
4
Use the original packaging if the device is to be transported.
All modifications of the device are forbidden for safety reasons.
Only use the device for its intended purpose. All other uses may lead to short circuits, burns, electroshocks,
crash, etc. Using the device in an unauthorized way will void the warranty.
4. Installation
a. Fitting the lamp
Use an Allen key and loosen the screws holding the cast aluminium housing of the
lamp hole. Loosen the 4 screws and open the cover.
After removing the cover you will see the 3 colour filters.
1. bulb
2. screw A
3. six mirrors distributes over 3 layers
4. screw B
5. reflecting cup
Carefully move the mirrors to the two sides so as to uncover the lamp. Use a Phillips-head screwdriver and carefully
loosen the two screws in order to remove the reflector. Removing the reflector will uncover the lamp socket.
b. Connecting the units
Connect the signal line output from the control panel to the signal line input from the first fixture. Next, connect the
output from the fixture to the input of the next fixture. Note that the DMX cable of the last fixture must be terminated
with a 120 resistance.
c. DMX512 Chain with Termination
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120 resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.
Please see illustrations.
d. Projector DMX Start Address Selection
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start
address is the channel number from which the device starts to “listen” to the DMX controller. Enter the correct
number and read it from the display located on the base of the VDP150CC6.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the VDP150CC6s will “listen” to the control signal on one particular
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you set
different addresses, each device will “listen” to a separate channel number. Changing the settings of one channel will
only affect the device in question.
In the case of the 6-channel VDP150CC6, you will have to set the start address of the first VDP150CC6 to 1, the
second VDP150CC6 to 7 (1 + 6), the third to 13 (7 + 6) and so on.
VDP150CC6_v2 HQ POWER
5
e. XLR Pin Layout
f. Mounting the Device
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
The carrying construction must be able to support 10 times the weight of the device for 1 hour without deforming.
The installation must always be secured with a secondary attachment e.g. a safety cable.
Never stand directly below the device when it is being mounted, removed or serviced. Have a qualified technician
check the device once a year and once before you bring it into service.
Install the device in a location with few passers-by that is inaccessible to unauthorized persons.
Overhead mounting requires extensive experience: calculating workload limits, determining the installation
material to be used… Have the material and the device itself checked regularly. Do not attempt to install the
device yourself if you lack these qualifications as improper installation may result in injuries.
Adjust the desired inclination angle via the mounting bracket and tighten the bracket screws.
Make sure there is no flammable material within a 0.5m radius of the device.
Have a qualified electrician carry out the electric connection.
Connect the device to the mains with the power plug. Do not connect it to a dimming pack.
The installation has to be approved by an expert before the device is taken into service.
5. Use
Set an address for stand-alone mode using DIP switches 1 to 10. See table below.
a. Stand-Alone Mode
Code Address Effect Binary No
0 0 White 0000000000
1 1 Blue 0000000001
2 2 Light blue 0000000010
3 3 Rose red 0000000011
4 4 Yellow 0000000100
5 5 Deep orchid 0000000101
6 6 Straw yellow 0000000110
7 7 Green 0000000111
8 8 Red 0000001000
9 9 Light yellow 0000001001
10 10 Magenta 0000001010
11 11 Mag-DBl-Bl-Gr-Wh-Yell-Red (30 sec) 0000001011
Address switches
DMX control and stand-alone selection
VDP150CC6_v2 HQ POWER
6
12 12 Mag-DBl-Bl-Gr-Wh-Yell-Red (20 sec) 0000001100
13 13 Mag-DBl-Bl-Gr-Wh-Yell-Red (10 sec) 0000001101
14 14 Mag-DBl-Bl-Gr-Yell-Red (30 sec) 0000001110
15 15 Mag-DBl-Bl-Gr-Yell-Red (20 sec) 0000001111
16 16 Mag-DBl-Bl-Gr-Yell-Red (10 sec) 0000010000
17 17 Mag-Bl-Yell (30 sec) 0000010001
18 18 Mag-Bl-Yell (20 sec) 0000010010
19 19 Mag-Bl-Yell (10 sec) 0000010011
20 20 Mag-Bl-Wh-Yell (30 sec) 0000010100
21 21 Mag-Bl-Wh-Yell (20 sec) 0000010101
22 22 Mag-Bl-Wh-Yell (10 sec) 0000010110
23 23 Mag-Yell-Red (30 sec) 0000010111
24 24 Mag-Wh-Yell (30 sec) 0000011000
25 25 Gr-Bl-Wh (30 sec) 0000011001
26 26 Gr-Bl-Wh-Yell (30 sec) 0000011010
27 27 Mag-DBl-Bl (30 sec) 0000011011
28 28 Mag-DBl-Bl-Wh (30 sec) 0000011100
b. Master/Slave Mode
Set the DIP switches of the master device as follows. Choose an address from the
table above.
Set the DIP switches of the slave device as follows. The slave device will react to
the master program.
When using the master-slave mode, the master should be set to address code “P2”. The slave must be set to 01.
You can only have one master in this mode; the slaves will follow the master program mode.
The master setting of the master-slave mode is the same as the auto mode. Refer to the table in “Stand-Alone
Mode” for the address code setting.
c. DMX512 Mode
The address can be selected by setting the DIP switches (binary system). See example below:
VDP150CC6_v2 HQ POWER
7
Channel DMX value Function
Speed 0 – 255 From slow to fast to control the changing of speed on the colour wheels
Yellow 0 – 255 From 0 to 100%
Magenta 0 – 255 From 0 to 100%
Blue 0 – 255 From 0 to 100%
0 – 25 White
26 – 50 Yellow
51 – 76 Magenta
77 – 102 Blue
103 – 128 Red
129 – 154 Green
155 – 180 D Blue
181 – 206 Magenta-DBlue-Blue-Green-White-Yellow-Red (30 sec)
207 – 232 Magenta-DBlue-Blue-Green-White-Yellow-Red (20 sec)
Colour effect
233 - 255 Magenta-DBlue-Blue-Green-White-Yellow-Red (10 sec)
Dimmer 0 – 255 From 0 to 100%
6. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts apart from the lamp.
8. Contact your dealer for spare parts if necessary.
7. Technical Specifications
Power Supply max. 230VAC / 50Hz
Power Consumption max. 250W
Lamp 1 x CDM-T 150W (order code LAMP150HTI/2 (Philips), (not incl.))
Protection Grade IP65
Dimensions 410 x 210 x 515mm
Total Weight 13kg
Max. Ambient Temperature 45°C
Max. Housing Temperature 80°C
For more info concerning this product, please visit our website www.hqpower.com.
The information in this manual is subject to change without prior notice.
VDP150CC6_v2 HQ POWER
11
10 10 Magenta 0000001010
11 11 Mag-DP-Bl-Gr-Wit-Geel-Rood (30 sec.) 0000001011
12 12 Mag-DP-Bl-Gr-Wit-Geel-Rood (20 sec.) 0000001100
13 13 Mag-DP-Bl-Gr-Wit-Geel-Rood (10 sec.) 0000001101
14 14 Mag-DP-Bl-Gr-Geel-Rood (30 sec.) 0000001110
15 15 Mag-DP-Bl-Gr-Geel-Rood (20 sec.) 0000001111
16 16 Mag-DP-Bl-Gr-Geel-Rood (10 sec.) 0000010000
17 17 Mag-Bl-Geel (30 sec.) 0000010001
18 18 Mag-Bl-Geel (20 sec.) 0000010010
19 19 Mag-Bl-Geel (10 sec.) 0000010011
20 20 Mag-Bl-Wh-Geel (30 sec.) 0000010100
21 21 Mag-Bl-Wh-Geel (20 sec.) 0000010101
22 22 Mag-Bl-Wh-Geel (10 sec.) 0000010110
23 23 Mag-Geel-Rood (30 sec.) 0000010111
24 24 Mag-Wit-Geel (30 sec.) 0000011000
25 25 Gr-Bl-Wit (30 sec.) 0000011001
26 26 Gr-Bl-Wit-Geel (30 sec.) 0000011010
27 27 Mag-DP-Bl (30 sec.) 0000011011
28 28 Mag-DP-Bl-Wit (30 sec.) 0000011100
b. Master/slave-modus
Plaats de DIP-schakelaars van het mastertoestel zoals hiernaast. Kies een adres uit
de tabel hierboven.
Plaats de DIP-schakelaars van het slavetoestel zoals hiernaast. Het slavetoestel
reageert nu volgens het masterprogramma.
In deze gebruiksmodus stelt u de adrescode op “P2”. Het slave-toestel stelt u op 01. Merk dat u in deze modus
slechts 1 master-toestel kunt hebben; de slave-toestellen volgen het programma van dit master-toestel.
De master-instelling is dezelfde als die van de stand-alonemodus. Raadpleeg de tabel in “Stand-alonemodus” voor
alle code-instellingen.
c. DMX512-modus
Selecteer het adres met
behulp van de DIP-
schakelaars (binair
systeem). Zie voorbeeld:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

HQ Power VDP150CC6 User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI