1. Turnoffelectricalpoweratcircuitbreakerordisconnect
2. Removeaccesspanel.
3. Verifypowerisoffatcontrolboardusingavoltmeter.
4. Removecontrolboxcover.(G20Runitswillnothaveacontrolboxcover).
5. Markanddisconnectwiresconnectedtothecontrolboard.
6. Removeblowercontrolboard.
7. InstallICM289blowercontrolboard.
8. ReconnectwirestoICM289controlboard.
9. Thequickconnectterminallabeled24VontheICM289is3/16”.Ifyourwire
forthe24Vterminalhada1/4””quickconnectterminalyoumustreplaceit
withthewireprovided.
10.Cutexistingwiresfromterminal24V,stripback5/8”andwirenutto
wireprovidedinkit.Connectterminatedendofprovidedwiretothe24V
terminalontheICM289blowercontrolboard.
11. Placeblowerpurgetimejumperoncorrectpins.
12.Placemech/electjumpertocorrectposition.
13.Reinstallthecontrolboxcover(allunitsexceptforG20R).
14.Replaceaccesspanel.
15.Turnonelectricalpowerfortheunit.
16.Testoperationperunitinstallationinstructions.
INSTALLATION
PACKAGE CONTENTS
(1)ICM289blowercontrol
(1)3/16”quickconnectterminatedwire
(1)Wirenut
FEATURES
• Controls inducer fan motor, blower fan and monitors limit switches
• Microprocessor based design
• Functions with all 24 VAC thermostats
SAFETY CONSIDERATIONS
Onlytrainedpersonnelshouldinstallorserviceheatingequipment.When
workingwithheatingequipment,besuretoreadandunderstandall
precautionsinthedocumentation,onlabels,andontagsthataccompany
theequipment.Failuretofollowallsafetyguidelinesmayresultindamageto
equipment,severepersonalinjuryordeath.
APPLICATION
ThisreplacementblowercontrolkitisforuseonG20,G20R,G23andG26seriesunits.TheICM289functionsthesameastheotherBCC(BCC1,BCC2,andBBC3)
controlboards.
ACCESSORY KIT
for an extended period
WireNut
ExistingWires
New3/16”TerminalWire
Replacement of
3/16” 24V Wire
SPECIFICATIONS
•Voltage Range:Line(98-132VAC)@60Hz
•Cool blower:20A@120VAC
•Heat blower:20A@120VAC
•Inducer motor:5A@120VAC
•Cool blower On Delay:1second
•Cool blower Off Delay:1second
•Heat blower On Delay:45seconds
•Heat blower Off Delay:90,150,220,270seconds
REPLACES
ReplacesallLennoxBCC1,BCC2andBCC3circuitboards,including48K98
and45K48.
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
CAUTION!
Use caution when installing and servicing the furnace to avoid and control
electrostatic discharge; ESD can impact electronic components. These
precautions must be followed to prevent electrostatic discharge from hand
tools and personnel. Following the precautions will protect the control from
ESD by discharging static electricity buildup to ground.
1. Disconnectallpowertothefurnace.Donottouchthecontrolorthewiring
priortodischargingyourbody’selectrostaticchargetoground.
2. Togroundyourself,touchyourhandandtoolstoaclean,metal(unpainted)
furnacesurfacenearthecontrolboard.
3. Servicethefurnaceaftertouchingthechassis.Yourbodywillrechargewith
staticelectricityasyoushufeyourfeetormovearound,andyoumust
regroundyourself.
4. Regroundyourselfifyoutouchungroundeditems.
5. Beforehandlinganewcontrol,regroundyourself;thiswillprotectthe
control.Storeusedandnewcontrolsinseparatecontainersbeforetouching
ungroundedobjects.