ZKTeco Mars-F1000 is a versatile flap barrier designed to manage pedestrian access in various settings. It features a sturdy construction that can withstand regular use and is suitable for both indoor and outdoor applications. The Mars-F1000 operates smoothly and quietly, providing a user-friendly experience for authorized personnel. It integrates seamlessly with access control systems, allowing for efficient and secure entry management. With its sleek design, the Mars-F1000 blends well with modern architectural styles, making it an ideal choice for offices, factories, and public venues.

ZKTeco Mars-F1000 is a versatile flap barrier designed to manage pedestrian access in various settings. It features a sturdy construction that can withstand regular use and is suitable for both indoor and outdoor applications. The Mars-F1000 operates smoothly and quietly, providing a user-friendly experience for authorized personnel. It integrates seamlessly with access control systems, allowing for efficient and secure entry management. With its sleek design, the Mars-F1000 blends well with modern architectural styles, making it an ideal choice for offices, factories, and public venues.

Installation Guide
Mars-F1000/Mars Pro-F1000
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the
actual product and the written information in this manual.
It is recommended that the flap barrier must be installed on a horizontal solid platform with a
height of 50mm to 100mm.
1.
After installation, check if the connection is done correctly at the connecting points of the ground
wire, at the connector assemblies and wiring points of the circuits, as well as at each movable part
of the ap barrier. Any loose nuts, screws and other fasteners should be tightened in time to avoid
any failures caused by long-time operations.
4.
1
1 Installation Requirements
The installation position of the ap barrier depends on its size. A distance of 100mm between the ap
barrier and the wall needs to be reserved for ease of opening the top cover of the machine to perform
maintenance and adjustment. The reference figure is shown below:
2 Installation Position
3. Make sure the ground wire of the system is reliably connected to avoid personal injuries or other
accidents.
2. It is also recommended that the flap barrier should not be used in the corrosive environment.
2103.73
180.00
301.24 180.00
301.24
600.00
274.27 274.28
301.24
180.00
600.00
310.94
710.66
310.94
710.66
274.27 274.28
100.00 100.00
1355.00
1010.00
3 Preparation
2
To install the Mars-F1000/Mars Pro-F1000 you must have:
A Screwdriver: To remove or install the screw on the device.
A Pencil: To mark the device size and the screw hole.
A Electric Drill: Drill holes according to the marked screw holes.
A Wrench: Secure the M12 expansion screw on the device.
4 Installation
1. Place the turnstile to the installation site.
4 Installation
Remove the screws fixing the top lid, and remove the top lid.
2.
3
Remove the side lid that hang on the device.
3.
4
Mark the floor following the periphery of the legs.
4.
120.00
1253.00
781.24 120.00
Take the turnstile aside and use the electric drill according to the drawn screw holes.
5.
6. Clean up the soil and dust after the drilling is completed, place the turnstile to the installation site
again.
5
Insert the M12 expansion screw and tighten it with a wrench.
7.
8. Connect the online cables and perform the power-on test. If the test is OK, install the side lid and
top lid of the device.
M12Expansion
Screw Tether Cable Power Line
100.00
1202.49
180.00
301.24 180.00
301.24
600.00
274.27
274.27
310.94
710.66
6
Power
Supply
Air Switch
9. It is recommended that a warning line be marked on the ground after installing the device, so as to
prompt the pedestrian to stand behind the warning line when verication.
10. If you need to assemble the swing arm by yourself, please refer to the diagram below for
installation.
Note: The swing arm is already installed in the factory.
7
ZKTeco Industrial Park, No. 32, Industrial Road,
Tangxia Town, Dongguan, China.
Phone : +86 769 - 82109991
Fax : +86 755 - 89602394
www.zkteco.com
Copyright 2021 ZKTECO CO., LTD. All Rights Reserved.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

ZKTeco Mars-F1000 Installation guide

Type
Installation guide

ZKTeco Mars-F1000 is a versatile flap barrier designed to manage pedestrian access in various settings. It features a sturdy construction that can withstand regular use and is suitable for both indoor and outdoor applications. The Mars-F1000 operates smoothly and quietly, providing a user-friendly experience for authorized personnel. It integrates seamlessly with access control systems, allowing for efficient and secure entry management. With its sleek design, the Mars-F1000 blends well with modern architectural styles, making it an ideal choice for offices, factories, and public venues.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI