Kichler Lighting 49287OZ User manual

Type
User manual
IS-49286-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
4) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
5) Push xture to wall over the protruding screws in the
mounng strap. Be sure not to pinch wires between wall
and canopy of xture.
6) Screw on the two (2) ball knobs[F] to the canopy[E]
Tighten to secure.
7) Insert recommended bulb(s). (Not supplied)
8) Slide the glass[G] into the sides of the xture frame
under the metal tabs and push the metal tabs up to the
glass to secure.
9) Slide the front glass[H] into the frame unl seated.
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting Strap
[B] Outlet Box
[C] Strap Mounting
Screws
[D] Mounting
Screws
[E] Canopy
[F] Ball Knobs
[G] Glass
[H] Front Glass
A
C
B
D
E
F
G
H
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/
OR IN WET LOCATIONS.
Mounng surface should be clean, dry, at and 1/4”
larger than the canopy on all sides. Any gaps between the
mounng surface and canopy exceeding 3/16” should be
corrected as required.
With silicone caulking compound, caulk completely
around where back of canopy meets the wall surface to
prevent water from seeping into outlet box.
1) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in canopy[E].
Thread mounng screws[D] into threaded holes starng
from outlet box[B] side.
2) Aach mounng strap to outlet box with strap mounng
screws[C]. Mounng strap can be adjusted to suit
posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
IS-49286-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
4) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
5) Push xture to wall over the protruding screws in the
mounng strap. Be sure not to pinch wires between wall
and canopy of xture.
6) Screw on the two (2) ball knobs[F] to the canopy[E]
Tighten to secure.
7) Insert recommended bulb(s). (Not supplied)
8) Slide the glass[G] into the sides of the xture frame
under the metal tabs and push the metal tabs up to the
glass to secure.
9) Slide the front glass[H] into the frame unl seated.
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting Strap
[B] Outlet Box
[C] Strap Mounting
Screws
[D] Mounting
Screws
[E] Canopy
[F] Ball Knobs
[G] Glass
[H] Front Glass
A
C
B
D
E
F
G
H
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/
OR IN WET LOCATIONS.
Mounng surface should be clean, dry, at and 1/4”
larger than the canopy on all sides. Any gaps between the
mounng surface and canopy exceeding 3/16” should be
corrected as required.
With silicone caulking compound, caulk completely
around where back of canopy meets the wall surface to
prevent water from seeping into outlet box.
1) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in canopy[E].
Thread mounng screws[D] into threaded holes starng
from outlet box[B] side.
2) Aach mounng strap to outlet box with strap mounng
screws[C]. Mounng strap can be adjusted to suit
posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 49287OZ User manual