Sub-Zero BI-48SID/S Installation guide

Type
Installation guide
CLASSIC REFRIGERATION
INSTALLATION GUIDE
SPECIFICATIONS, INSTALLATION, AND MORE
2 | Sub-Zero Customer Care 800.222.7820
Important Note
To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
CLASSIC REFRIGERATION
Contents
3 Classic Refrigeration
4 Opening Dimensions
8 Dual Installation
8 Electrical
9 Plumbing
9 Preparation
10 Anti-Tip Bracket
12 Placement
12 Water Line
13 Custom Panels
16 Alignment
17 Completion
Features and specications are subject to change at any
time without notice. Visit subzero.com/specs for the most
up-to-date information.
subzero.com | 3
Product Information
Important product information, including the model and
serial number, are listed on the product rating plate. The
rating plate is located at the top frame of the unit, inside the
door. Refer to the illustration below.
If service is necessary, contact Sub-Zero Factory Certied
Service with the model and serial number. For the name
of the nearest Sub-Zero Factory Certied Service or for
questions regarding the installation, visit the Support
and Service section of our website, subzero.com, or call
Sub-Zero Customer Care at 800-222-7820.
Tools and Materials
Screwdrivers—standard and Phillips.
Power drill.
Drill bits (masonry bits required for concrete installation).
Torx drives—T-10, 15, and 20.
Standard Allen wrench set.
Standard socket and wrench set.
2' and 4' levels.
Tubing cutter.
3' of
1
/4" OD copper, braided stainless steel, or PEX
tubing.
Saddle valve.
Material to protect home, ooring, and cabinetry during
installation.
Rating plate location
RATING
PLATE
CLASSIC REFRIGERATION
4 | Sub-Zero Customer Care 800.222.7820
SITE PREPARATION
Opening Dimensions
STANDARD INSTALLATION
3
/
4
"
(19)
TYPICAL
FRAMED
CABINETRY
W
FILLER
3
1
/
2
"
(89)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
/4" (19)
TYPICAL
3
1
/2" (89)
FINISHED
RETURN
NOTE:
3
1
/2" (89) finished returns will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit
.
83
3
/4"
(2127)
OPENING
HEIGHT
24" (610)
OPENING
DEPTH
FRONT VIEW
SIDE
VIEW
TOP VIEW
W
OPENING WIDTH
If two units are installed side by side, refer to page 6.
OPENING WIDTH
W
30" Model 29
1
/2" (749)
36" Model 35
1
/2" (902)
42" Model 41
1
/2" (1054)
48" Model 47
1
/2" (1206)
subzero.com | 5
Opening Dimensions
FLUSH INSET INSTALLATION
Dimensions assume a
3
/4" (19) panel thickness. If two units
are installed side by side, refer to page 7.
84"
(2134)
FLUSH
INSET
HEIGHT
1
/4"
(6)
26
3
/16"
(665)
FLUSH
INSET
DEPTH
2
3
/16"
(56)
NOTE:
3
1
/2" (89) finished returns and shaded areas will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit with
3
/4" (19) panel.
FRONT VIEW
SIDE
VIEW
TOP VIEW
1
1
/4"
(32)
W
FLUSH INSET WIDTH
FINISHED
CLEATS
5
11
/16"
(145)
FINISHED
RETURN
FILLER
FRAMED
CABINETRY
W
CLEAT
3
/4" (19)
TYPICAL
3
1
/2"
(89)
5
11
/
16
"
(145)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
1
/2"
(89)
CLEAT
3
/4" (19)
TYPICAL
SITE PREPARATION
FLUSH INSET WIDTH
W
30" Model 32" (813)
36" Model 38" (965)
42" Model 44" (1118)
48" Model 50" (1270)
6 | Sub-Zero Customer Care 800.222.7820
Opening Dimensions
DUAL STANDARD INSTALLATION
NOTE:
3
1
/2" (89) finished returns will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit
.
83
3
/4"
(2127)
OPENING
HEIGHT
24" (610)
OPENING
DEPTH
FRONT VIEW
SIDE
VIEW
TOP VIEW
W
OPENING WIDTH
3
/
4
"
(19)
TYPICAL
FRAMED
CABINETRY
W
FILLER
3
1
/
2
"
(89)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
/4" (19)
TYPICAL
3
1
/2" (89)
FINISHED
RETURN
A dual installation kit is required for this installation.
SITE PREPARATION
DUAL OPENING WIDTH
W
Two 30" Models 59
3
/4" (1518)
30" and 36" Models 65
3
/4" (1670)
Two 36" Models 71
3
/4" (1822)
subzero.com | 7
Opening Dimensions
DUAL FLUSH INSET INSTALLATION
84"
(2134)
FLUSH
INSET
HEIGHT
1
/4"
(6)
26
3
/16"
(665)
FLUSH
INSET
DEPTH
2
3
/16"
(56)
FRONT VIEW
SIDE
VIEW
TOP VIEW
FINISHED
CLEATS
1
1
/4"
(32)
W
FLUSH INSET WIDTH
NOTE:
3
1
/2" (89) finished returns and shaded areas will be visible and should be finished to match cabinetry.
Shaded line represents profile of unit with
3
/4" (19) panel.
5
11
/16"
(145)
FINISHED
RETURN
FILLER
FRAMED
CABINETRY
W
CLEAT
3
/4" (19)
TYPICAL
3
1
/2"
(89)
5
11
/
16
"
(145)
FINISHED
RETURN
FRAMELESS
CABINETRY
W
3
1
/2"
(89)
CLEAT
3
/4" (19)
TYPICAL
Dimensions assume a
3
/4" (19) panel thickness. A dual instal-
lation kit is required for this installation.
SITE PREPARATION
DUAL FLUSH INSET WIDTH
W
Two 30" Models 62
1
/4" (1581)
30" and 36" Models 68
1
/4" (1734)
Two 36" Models 74
1
/4" (1886)
8 | Sub-Zero Customer Care 800.222.7820
SITE PREPARATION
Electrical Requirements
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded
area shown in the illustration below. A separate circuit ser-
vicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause inter-
ruption of operation.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
CAUTION
The outlet must be checked by a qualied electrician
to be sure it is wired with the correct polarity. Verify the
outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
75
1
/2" (1918)
FROM FLOOR
7"
(178)
E
6"
(152)
RIGHT SIDE
OF OPENING
Electrical supply location
Dual Installation
If two units are installed side by side, a dual installation kit
may be required. Installations without a custom ller strip
require a dual installation kit. If a dual installation kit is not
specied, a 2"
(51) ller strip is recommended between units.
Dual installations without a ller strip can only be accom-
plished using two units with opposite hinges. Refer to the
illustrations below.
Dual installation kits are available through an authorized
Sub-Zero dealer. For local dealer information, visit the nd a
showroom section of our website, subzero.com. For ques-
tions regarding the installation, call Sub-Zero Customer
Care at 800-222-7820.
WITHOUT FILLER STRIP
FILLER STRIP
Opposite hinges
Same side hinges
subzero.com | 9
SITE PREPARATION
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
The water supply line should be located within the shaded
area shown in the illustration below. The water supply line
should be connected to the house supply with an easily
accessible shut-off valve. Do not use self-piercing valves.
The water supply line must not interfere with the installation
of the anti-tip brackets.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
(2.4–8.3 bar) supplied
to the unit at all times. In this application, the water ltration
system must be bypassed by removing the lter. A copper
line is not recommended for this application.
PLUMBING REQUIREMENTS
Water Supply
1
/4" OD copper, braided
stainless steel, or PEX tubing
Pressure 35–120 psi
(2.4–8.3 bar)
Excess Line for Connection 36" (914)
Preparation
Uncrate the unit and inspect for damage. Remove the wood
base and discard the shipping bolts and brackets. Remove
and recycle packing materials. Do not discard the kickplate,
anti-tip brackets, and hardware.
Completely retract the front leveling legs to allow the unit to
be moved into position. The front and rear leveling legs can
be adjusted from the front once the unit is in position.
Remove the drain pan from the base of the unit to avoid
damage and to allow for proper placement of the appliance
dolly.
The grille assembly should be removed prior to moving the
unit. To remove, pull out on the bottom edge of the grille and
rotate upward. Loosen the back two grille mounting screws
and remove the front two grille mounting screws. Refer to
the illustrations below. With the grille held rmly, pull forward
to remove.
BACK GRILLE
SCREW
FRONT
GRILLE SCREW
Grille removal
Grille mounting screws
3" (76)
18" (457)
6" (152)
RIGHT SIDE
OF OPENING
AREA EXTENDS
1
/2" (13)
FORWARD ON FLOOR
Water supply location
10 | Sub-Zero Customer Care 800.222.7820
SITE PREPARATION
WOOD FLOOR APPLICATION
After properly locating the anti-tip brackets in the opening,
drill pilot holes
3
/16" (5) diameter maximum in the wall studs
or wall plate. Use the #12 screws and washers to secure the
brackets. Verify the screws penetrate through the ooring
material and into the wall studs or wall plate a minimum of
3
/4" (19). Refer to the illustration below.
CONCRETE FLOOR APPLICATION
After properly locating the anti-tip brackets in the opening,
drill pilot holes
3
/16" (5) diameter maximum in the wall studs
or wall plate. Drill
3
/8" (10) diameter holes into the concrete
a minimum of 1
1
/2" (38) deep. Use the #12 screws and
washers to secure the brackets to the wall, and use the
3
/8"
wedge anchors to secure the brackets to the oor. Verify
the screws penetrate the wall studs or wall plate a minimum
of
3
/4" (19). Refer to the illustration below.
4" (102)
MIN
24"
(610)
SUBFLOORING
WOOD FLOOR
WALL PLATE
FINISHED
FLOORING
4" (102)
MIN
24"
(610)
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
1
1
/2"(38)
min
SUBFLOORING
CONCRETE
FLOOR
WALL PLATE
FINISHED
FLOORING
1
1
/2"(38)
MIN
Wood oor
Concrete oor
Anti-Tip Bracket
WARNING
To prevent the unit from tipping forward, the anti-tip
brackets must be installed.
The two anti-tip brackets must be installed exactly 24"
(610)
from the front of the opening to the back of the
brackets and a minimum of 4"
(102) from the sides of the
opening. This depth will increase to 26
3
/16" (665) for a ush
inset installation based on
3
/4" (19) thick panels. Failure to
properly position the anti-tip brackets will prevent proper
engagement.
Use all anti-tip bracket hardware as instructed for wood or
concrete oors.
IMPORTANT NOTE: For wood or concrete oor applications,
if the #12 screws do not hit a wall stud or wall plate, use the
#8 screws and #12 washers with the wall anchors.
IMPORTANT NOTE: In some installations the subooring or
nished oor may necessitate angling the screws used to
fasten the anti-tip brackets to the back wall.
ANTI-TIP HARDWARE
2 Anti-tip brackets
12 #12 x 2
1
/2" pan head screws
4
3
/8"–16 x 3
3
/4" wedge anchors
12 #12 at washers
4 #8–18 x 1
1
/4" truss head screws
4 Nylon Zip-it
®
wall anchors
subzero.com | 11
SITE PREPARATION
Anti-Tip Bracket
CONCRETE WEDGE ANCHOR INSTALLATION
1 Drill a
3
/8" (10) diameter hole any depth exceeding the
minimum embedment. Clean the hole or drill additional
depth to accommodate the drill nes.
2 Assemble the washer and nut ush with the end of
anchor to protect threads. Drive the anchor through the
material to be fastened until the washer is ush with the
surface material.
3 Expand the anchor by tightening the nut 3–5 turns past
hand-tight position or to 25 foot-pounds of torque.
WARNING
Verify there are no electrical wires or plumbing in the
area which the screws could penetrate.
CAUTION
Always wear safety glasses and use other necessary
protective devices or apparel when installing or working
with anchors.
Anchors are not recommended for use in lightweight
masonry material such as block or brick, or for use in
new concrete which has not had sufcient time to cure.
The use of core drills is not recommended to drill holes
for the anchors.
12 | Sub-Zero Customer Care 800.222.7820
INSTALLATION
Water Line
Approximately 3' (.9 m) of
1
/4" plastic tubing is connected to
the unit with a preassembled
1
/4" compression connection
under the unit. The water line tting connection kit, provided
with the unit, contains a
1
/4" compression union tting for
connection to the household water line.
Purge the water line prior to nal connection to the unit. This
will remove any debris that may be present in the tubing
from installing the new water line.
Place the sleeve and nut on the water line and fasten to the
connection at the end of the tubing. Do not over tighten.
Check all water line ttings for leaks. Verify the drain pan
can be installed and removed without interference with the
water line.
IMPORTANT NOTE: If a reverse osmosis system is used, it
is recommended the water ltration system be bypassed by
removing the lter.
IMPORTANT NOTE: Water lines cannot be exposed to
freezing temperatures.
Placement
CAUTION
Before moving the unit into position, secure door(s)
closed and protect any nished ooring.
Use an appliance dolly to move the unit near the opening.
If the unit has been on its back or side, it must stand upright
for a minimum of 24 hours before connecting power.
Plug the power cord into the grounded outlet and roll the
unit into position. Verify the anti-tip brackets are properly
engaged.
IMPORTANT NOTE: If used, the side panels must be
installed before the unit is placed in its nal position. Refer
to page 15.
subzero.com | 13
EXTERNAL DISPENSER
For external dispenser models, the dispenser bezel must be
removed before the custom panels can be installed.
The bezel will accommodate a
1
/4" (6) thick panel for framed
applications and a
3
/4" (19) thick panel for overlay and
ush inset applications. Panels thicker than
3
/4" (19) must
be routed in the dispenser area to 1
1
/8" (29) (including the
backer and spacer panels).
To Remove the Bezel:
1 Lift, rotate, and remove the tray.
2 Lift and remove the grille.
3 Remove the screw from the center of the chute and
remove the chute.
4 Rotate the control panel downward and disconnect the
wire harness.
5 Remove the screws from each corner of the bezel and
pull the bezel forward.
PANEL INSTALLATION
Custom Panels
For overlay and ush inset applications, custom door and
grille panels must be installed. The panel size is critical for
a proper t. To verify panel requirements and dimensions,
refer to the Sub-Zero Design Guide at subzero.com/specs.
IMPORTANT NOTE: Flush inset applications require a
minimum
1
/2" (13) reveal on all sides.
Finish all sides of the custom panels. They may be visible
when the door is open or through the window of glass door
models.
GRILLE
TRAY
CHUTE
Tray and grille removal
Dispenser bezel removal
14 | Sub-Zero Customer Care 800.222.7820
PANEL INSTALLATION
Custom Panels
DOOR PANELS
To install custom door panels, remove the handle side trim
molding. Insert a screwdriver tip into the top corner slot
on the handle side and pop out the trim. For the drawer,
insert a screwdriver tip into the slot on either side of the trim
running along the top of the drawer and pop out the trim.
Remove the screws and frame. Refer to the illustrations
below.
The door has a
1
/4" (6) frame for the custom panel to slide
into. If the panel is thicker than
1
/4" (6), rout an edge around
the panel or mount the panel on a sheet of
1
/4" (6) thick
material, then insert into the frame.
A .10"
(3) space is required between the backer panel and
the custom panel to allow the panel to slide into the door
frame. Refer to the illustrations below for critical dimensions.
Install handle hardware before inserting the panel. Large
D-style handles are recommended rather than knobs. Screw
heads must be countersunk into the panel.
Slide the panel into the frame.
To reinstall the door trim molding, insert the top of the trim
into grooves at the top of the door and work downward,
snapping the trim into clips on the door frame. For the
drawer, start at one end and move towards the opposite
end, snapping the trim into the clips.
1
/8" (3) (OVERLAY)
CUSTOM PANEL
SPACER PANEL
BACKER PANEL
TRIM
5
/16" (8) min
1
/4" (6)
.10" (3)
CUSTOM
PANEL
SPACER
PANEL
BACKER
PANEL
3
/4"
(19)
typical
Panel assembly cross section
(overlay)
Panel assembly rear view
Door side trim
Drawer top trim
subzero.com | 15
Custom Panels
GRILLE PANEL
Remove the bottom grille frame by extracting the two lower
corner screws from each side of the grille assembly. Refer to
the illustration below.
With the bottom section removed, slide the custom grille
panel into the frame. If the panel is thinner than
1
/4" (6), a
ller material will need to be installed to achieve a proper
t. Once the panel is installed, reattach the bottom grille
frame by sliding the corner brackets back into position, then
reinstall the four corner screws.
PANEL INSTALLATION
SIDE PANEL
When installing a custom side panel, an accessory kit is
required and is available through an authorized Sub-Zero
dealer. For local dealer information, visit the nd a show-
room section of our website, subzero.com. Stainless steel
and white enamel side panels are also available from an
authorized Sub-Zero dealer.
IMPORTANT NOTE: The use of side panels may change the
width of the opening.
A custom side panel must be a minimum of 24"
(610) deep
and
1
/2" (13) thick. Routing will be necessary for the side
panel to t ush against the side of the unit. Refer to the
illustrations below.
IMPORTANT NOTE: The height of the side panel will vary
with the height of the grille. Verify the nished height before
modifying the panels.
IMPORTANT NOTE: For over-and-under and French door
models, additional routing will be necessary to accommo-
date the lower hinge plate of the refrigerator.
84"
(2134)
24"
(610)
ROUT TO
3
/16" (5)
(OVER-AND-UNDER
MODELS)
OPTIONAL
TOE KICK
CUT-OUT
4" (102)
20
1
/2"
(521)
5
3
/4"
(146)
1
7
/8"(48)
1" (25)
4
1
/4" (108)
ROUT TO
1
/8" (3)
FRONT
OF SIDE
PANEL
2
5
/8"
(67)
MAIN
FRAME
SIDE PANEL
ROUTING
1" (25)
1
7
/8" (48)
1
/8" (3)
1
/2" (13)
Side panel dimensions
Routing detail
BOTTOM
GRILLE
FRAME
Grille frame assembly
16 | Sub-Zero Customer Care 800.222.7820
INSTALLATION
DOOR ADJUSTMENT
The doors of side-by-side and over-and-under models can
be adjusted in and out, and side to side tilt. The doors of
side-by-side models can also be adjusted up and down.
To make adjustments, slightly loosening the two upper hinge
bolts on the upper hinge plate using a
1
/2" wrench. Refer to
the illustration below.
In-and-Out Adjustment: For a left-hinge door, using a
5
/32" allen wrench, turn the adjustment bolt clockwise to
bring the handle side of the door inward, and counterclock-
wise to move the handle side outward. Reverse directions
for a right-hinge door.
Side-to-Side Tilt Adjustment: For a left-hinge door, using a
3
/8" wrench, turn the adjustment bolt clockwise to raise the
handle side of the door, and counterclockwise to lower the
handle side. Reverse directions for a right-hinge door.
Up-and-Down Adjustment: For a left-hinge door, using a
1
/4" allen wrench, turn the adjustment bolt clockwise to raise
the door and counterclockwise to lower. Refer to the illustra-
tion below. Reverse directions for a right-hinge door.
Alignment
LEVELING
Once the unit is in position, turn the front leveling legs
clockwise to adjust the height. The rear height adjustment
can be made from the front of the roller base. Using a
3
/8"
socket, turn the
3
/8" hex bolt clockwise to raise the unit or
counterclockwise to lower. Use the lowest torque setting
when using a power drill. Do not turn the rear leveling legs
by hand. Refer to the illustration below.
When the unit is properly leveled, door and drawer adjust-
ments are less likely to be necessary.
IMPORTANT NOTE: Level the unit to the oor, not the sur-
rounding cabinetry. This could affect the operation of the
unit, such as door closing.
WARNING
To reduce the possibility of the unit tipping forward, the
front leveling legs must be in contact with the oor.
FRONT
LEVELING LEG
REAR
ADJUSTMENT
Rear roller base adjustment
UPPER
HINGE BOLTS
SIDE-TO-SIDE
TILT ADJUSTMENT
IN-AND-OUT
ADJUSTMENT
Door adjustment bolts
Up-and-down door adjustment
subzero.com | 17
INSTALLATION
ANCHORING
After the unit has been leveled and door adjustment com-
pleted, anchor the unit to the opening to ensure a proper t
and secure installation.
To anchor the top of the unit, open the grille and install the
screws provided through the grille frame into cabinetry.
There are several hole locations. Refer to the illustration
below. Check for proper door clearance by opening the
door.
To anchor the bottom of the unit, drive a screw through the
side hole inside each roller base assembly. The screw will
need to go in at an angle to attach properly. Refer to the
illustration below. Additional material may be needed behind
the cleat to ensure sufcient anchoring.
CAUTION
If the screws provided are not suitable for the installa-
tion, use adequate screws.
ANCHORING
SCREWS
ANCHORING
SCREW
Top anchoring
Bottom anchoring
Completion
GRILLE INSTALLATION
Install the grille assembly and check for proper t. The grille
is designed to rest on the upper door hinge(s) to minimize
the reveal between the top of the door and bottom of the
grille. To eliminate interference, the grille height can be
adjusted. Loosen the four grille adjustment screws (two on
each side) and adjust the grille height as needed. Refer to
the illustration below.
BACK GRILLE
SCREW
FRONT
GRILLE SCREW
GRILLE
ADJUSTMENT
SCREW
Grille height adjustment
18 | Sub-Zero Customer Care 800.222.7820
Completion
Reinstall the drain pan and verify it is in the proper position.
Install the kickplate using the screws to attach it to the
brackets on the inside of each roller base. Refer to the illus-
tration below. The kickplate must be removable for service.
The oor cannot interfere with removal. Refer to the label
mounted on the kickplate support for height clearance.
Turn power on by touching POWER on the control panel.
Install the light diffuser by aligning the slots of the light
diffuser onto the bracket pegs and pulling forward so the
tabs on the slots engage the bracket pegs. Refer to the
illustration below.
INSTALLATION
PEG
SLOT
Kickplate installation
Light diffuser installation
WATER FILTER BYPASS
If the water ltration system will not be used, it can be
placed in water lter bypass mode by removing the water
lter. Refer to the illustration below. Follow these steps to
remove the water lter:
1 Pull out on the bottom edge of the grille assembly and
tilt the grille frame upward.
2 To remove the cartridge, rotate the cartridge counter-
clockwise one-quarter turn and pull out. Refer to the
illustration below.
WATER
FILTER
WATER FILTER
Location of water lter
Water lter removal
subzero.com | 19
WARNING
Follow all city and state laws when storing, recycling,
or discarding unused refrigerators and freezers.
Completion
90° DOOR STOP
The doors of all models open to 110°. A 90° door stop is
provided with the unit (located behind the grille). Additional
90° door stop kits are available through an authorized
Sub-Zero dealer.
INSTALLATION
Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf &
Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.
6 | Atención al cliente de Sub-Zero 800.222.7820
Dimensiones de abertura
INSTALACIÓN ESTÁNDAR DOBLE
ANCHURA DE ABERTURA
A
Dos modelos de 30" (762) 59
3
/4" (1518)
Modelos de 30" (762) y 36" (914) 65
3
/4" (1670)
Dos modelos de 36" (914) 71
3
/4" (1822)
Para esta instalación se requiere un kit de instalación doble.
PREPARACIÓN DEL SITIO
TÍPICO
DE
3
/
4
"
(19)
GABINETE CON
MARCO
A
RELLENO
TUBO DE
RETORNO DE
3
1
/2" (89) CON
ACABADOS
TUBO DE
RETORNO DE
3
1
/2" (89) CON
ACABADOS
GABINETE SIN
MARCO
A
TÍPICO
DE
3
/4" (19)
NOTA: Los tubos de retorno de
3
1
/2" (89) con acabados se podrán ver y se deben terminar para que se ajusten a los gabinetes.
La línea sombreada representa el perfil de la unidad.
83
3
/4"
(2127)
ALTURA DE
LA ABERTURA
VISTA FRONTAL
VIST
A LATERAL
VISTA SUPERIOR
A
ANCHURA DE
ABERTURA
24" (610)
PROFUNDIDAD
DE LA
ABERTURA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Sub-Zero BI-48SID/S Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI