Airflow Sound Insulation Element For Soffit Channel Installation Operating instructions

Type
Operating instructions
© Airow - we reserve the right to make changes without prior notice
Uno hab Sound Insulation Element
Installation and Operating Instructions
INSTALLATION AND OPERATING INSTRUCTIONS
In order to ensure complete and effective
operation and for your own safety, all of
the following
instructions should be read
carefully and observed.
DELIVERY
Sound insulation element for wall sleeve( SWS)
is packaged with shrink wrapped. The window
version (SSC) is packaged in a corrugated box.
R RECEIPT
The shipment must be checked for damage and
correctness immediately upon delivery. If there
is any damage, promptly report the damage
by consulting the transport company. If
complaints are not made within the agreed
period, any claims could be lost.
STANDARD SOUND LEVEL DIFFERENCE
D
n,e,w
Each installed sound insulation element (SWS and
SSC) improves the standard sound level difference
D
n,e,w
by 2 dB on average.
SOUND PRESSURE LEVEL L
PA
Each installed sound insulation element SWS
reduces the sound pressure level L
PA
of the unit by
1 dB on average.
STORAGE
The storage location must be water-protected and
free from temperature uctuations. Persistent direct
UV irradiation must be avoided. Damages due to
improper transportation, storage or commissioning
must be veried and are not liable warranty.
AREA OF APPLICATION
For effective sound insulation in a decentralised
ventilation unit. In order to increase the sound
insulation, the sound insulation elements can also
be mounted in series one behind the other.
ADVANTAGES
Optimum external sound insulation
Optimum reduction of unit sounds
Simple installation by inserting into the wall
sleeve or soft screen
The loss of ow is approx. 1% per sound
insulation element SWS and approx. 2% per
SSC due to the ow-optimised geometry.
MATERIAL
Open-cell foam made from melamine resin
The product meets re protection class B1
according to DIN 4102-1
INSTALLATION
Sound Insulation Element for wall sleeve (SWS)
First, insert the unit into the wall sleeve. Sound
insulation elements can be inserted between
the unit and the inside panel.
The recess in the circumferential edge of
the sound insulation element acts as a cable
guide and must be at the bottom. The sound
insulation elements must be installed aligned
with each other, note the orientation of the air
ducts, see Fig.2.
NOTE: The sound insulation elements have a
central slot, so that they can be lined up on a metre
stick for simple insertion into the wall sleeve!
Sound Insulation Element for window wall (SSC)
Once the wall grill is removed, up to three sound
insulation elements SSC hooked to each other can
be inserted into the window wall channel. The
central rail must be in the direction of the house
wall, see Fig. 2. The SSC should be inserted
deep enough into the screen that it is
still accessible by hand for removal.
MAINTENANCE / CLEANING
In order to ensure proper functioning, the sound
insulation elements should be checked during
each filter change and carefully vacuumed with a
vacuum cleaner, if necessary.
ACCESSORIES
The use of accessories which are not recommended
or offered by Airflow is not permitted. Any potential
damage is not covered by warranty.
WARRANTY CLAIMS – EXCLUSION OF
LIABILITY
If the instructions in this documentation are not
observed, all warranty claims shall be excluded.
This also applies to any liability claims extended to
the manufacturer.
REGULATIONS – GUIDELINES
If the installation and operating instructions are
observed,
the product conforms to the
applicable international regulations.
SWS is the Sound insulation element for wall
sleeve installation. SSC is the Sound insulation
element for window channel kit installation.
SWS SSC
Uno hab
ventilation unit
Sound Insulation Element for
wall sleeve (SWS)
Insect screen
Sound Insulation Element for
window wall (SSC)
D
n,e,w
44 dB -2 dB/unit (max. -8 dB) -3 dB -2 dB/unit (max. -6 dB)
180
94
32
156
50
Fig.1
Sound Insulation Element for wall sleeve (SWS)
Sound Insulation Element for window wall (SSC)
Standard sound level difference D
n,e,w
Uno hab Sound Insulation Element
Installation and Operating Instructions
E-mail: info@airow.com
Telephone: +44 (0) 1494 525252
airow.com
© Airow Developments Limited. Airow
Developments Limited reserve the right, in the
interests of continuous development, to alter
specications without prior notice. All orders
are accepted subject to our conditions of sale
which are available on request
Certificate No. EMS 569454
BS EN 1SO 14001 : 2015
Certificate No. FM 00152
BS EN 1SO 9001 : 2015
Airow Developments Limited
Aidelle House, Lancaster Road,
Cressex Business Park,
High Wycombe, Buckinghamshire,
United Kingdom, HP12 3QP
Call: 01494 525252 Visit: airow.com
80000790 - Issue 2 09/20
Wandeinbauhülse
Lüftungseinheit
Schalldämm-Elemente
(bis zu 4 Stück)
Mehrere Schalldämm-Elemente
können mittels Meterstab
zueinander ausgerichtet werden
Außenblende
Freischnitt für
Anschlussleitung
nach unten
Drallrichtung beachten
Fig.2
Sound Insulation Element for wall sleeve (SWS)
Sound Insulation Element for window wall (SSC)
Outer panel
Ventilation unit
Wall installation sleeve
Sound insulation elements
(up to 4 units)
Note lay direction
Multiple sound insulation elements
can be aligned with each other
using a metre stick
Outlet for connection
line at bottom
Condensation
drain
Frame
Soffit screen
Guide rails for
positioning in the soffit
screen
Central guide rail
towards the house wall
Hook
Bracket
Contact surface towards
the house wall
When installing multiple sound
insulation elements, mount hook to
bracket to allow removal in case of
revision
  • Page 1 1
  • Page 2 2

Airflow Sound Insulation Element For Soffit Channel Installation Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI