Proo ng
Cabinet
FL-0300-3
Rev. 7 (3/10) Page 1 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 120B and 121B Series Proo ng Cabinets
ELECTRICAL SPECIFICATIONS:
Model No. Volts Watts Amps Hertz Phase NEMA
120-1816B
-1836B
120 1000 8.3 60 1 5-15
121-1816B 120 1000 8.3 60 1 5-15
120-1816B 240
-1836B 240
240 900 3.8 60 1 6-15
121-1816B 240 240 900 3.8 60 1 6-15
All are designed for AC service.
PARTS IDENTIFICATION
1. Power Switch
2. Thermostat (Reservoir)
3. Temperature Display
4. Water Pan
HOW TO INSTALL CABINET:
Place cabinet near warm ovens. Do 1. NOT put in
drafty areas or near ventilating systems.
Plug cord into receptacle in back of unit.2.
Turn plug clockwise to lock. 3.
Plug other end into proper wall outlet.4.
Fill water pan (following steps a-c).5.
a. Lift off cover.
b. Fill with 3.5 qts. (3.3 liters) water.
Replace cover.
c. Adjust vents on cover to half open.
CAUTION
Use of treated or
soft water may be
required for proper
operation and to maintain warranty.
1
2
3
4
FIGURE 1 FIGURE 2
Machine
Screw
Twist clockwise and
lock for connection
Standard
3-prong plug
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 120 and 121 Series Proo ng Cabinets
Proo ng
Cabinet
FL-0300-3
Rev. 7 (3/10) Page 2 of 4
Allow cabinet to cool.1.
Remove Hot unit from cabinet.2.
Do NOT use abrasives or harsh 3.
chemicals.
HOW TO CLEAN THE CABINET:
WARNING
BEFORE cleaning
the cabinet:
HOW TO START UNIT:
Turn the POWER switch on. The 1. Yellow light will
come on.
Turn thermostat to #10.2.
Preheat cabinet for 30 minutes.3.
Put fresh or fully thawed dough into cabinet.4.
NOTE: The cabinet temperature will drop temperature
inside cabinet if cold dough is added.
Do NOT put frozen dough into cabinet
Turn thermostat to #9 and close door.5.
NOTE: No. 9 setting will give you a temperature of
95°F, and 90-95% humidity. Experiment with
different settings to get the exact temperature
and humidity you need. The thermometer shows
the temperature inside.
NOTE: Check water level in water pan if you are
proo ng longer than 90 minutes. Fill with hot
water.
MAINTENANCE
HOT UNIT REMOVAL INSTRUCTIONS:
Unplug cord set from wall outlet and from back of 1.
cabinet.
Remove one screw from back of cabinet that is 2.
above receptacle.
Slide the whole unit out the front of the cabinet.3.
HOW TO TURN UNIT OFF:
Turn thermostat off. The red light will go out.1.
Turn the POWER switch off. The 2. Yellow light will
go out.
Cleaning hints:
Wipe up spills as soon as possible.1.
Clean cabinet regularly to avoid heavy dirt build-up.2.
Make a test spot with cleaner.3.
Follow manufacturers directions on cleaner.4.
Do not mix cleaners.5.
Avoid drips and splashes.6.
HOW TO CLEAN THE UNIT:
Soil Cleaner Method
DOOR
(Polycarbonate)
DIRT Mild *detergent and water.
1. Wipe with soft, damp cloth.
2. Rinse well.
GREASE and OIL Weak, alcohol-type cleaner.
1. Wipe with soft, damp cloth.
2. Rinse well.
CABINET
(Aluminum)
Inside
and
Outside
DIRT Mild *detergent and hot
water, or mild abrasive
cleaner.
1. Use soft, damp cloth.
2. Rinse with hot water.
3. Wipe dry
Steam (no strong alkaline
additive)
1. Rinse after steam cleaning.
2. Wipe dry.
FINGERPRINTS,
GREASE and OIL
Chemical oven cleaner for
aluminum
Follow oven cleaner manufacturers
directions.
Mild abrasive cleaner; oily
or waxy cleaner.
Apply with soft, clean cloth.
WATER SPOTS Mild abrasive cleaner 1. Apply with damp cloth.
2. Rinse and dry.
*Mild detergents include soaps and non-abrasive cleaners.
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
Proo ng
Cabinet
FL-0300-3
Rev. 7 (3/10) Page 3 of 4
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 120B and 121B Series Proo ng Cabinets
TROUBLE-SHOOTING CHART:
FAILURE POSSIBLE CAUSE
1. Yellow light at switch does not light.
1a. Circuit breaker/fuse to wall outlet is blown.
1b. Cord is unplugged from wall outlet or cabinet.
1c. Switch is “OFF”.
2. Unit does not get hot.
2a. Thermostat set too low or is “OFF”.
2b. Water in pan may be low.
2c. Switch is “OFF”.
3. Unit will not turn off. 3a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
4. Humidity is low 4a. Water in pan may be low
4b. Thermostat set too low
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400.
Instructions for replacing parts are included in replacement parts kits.
CAUTION
DELIME OR DESCALE RESERVOIR PARTS AS REQUIRED
TO PREVENT DAMAGING BUILD-UP.
WARRANTY COVERAGE MAY BE AFFECTED WITHOUT PROPER CLEANING.
REPLACEMENT PARTS:
DESCRIPTION 120 VOLT 240 VOLT
Proof Unit .............................................PU-18-747-42 ............PU-18-747-43
Water Pan ..............................................1019-002 ....................1019-002
Water Pan Cover ...................................1245-001 ....................1245-001
Heater Kit .............................................0811-005-K ................0811-015-K
Water Pan with Heater Kit ....................0756-014 ....................0756-015
Thermostat Kit ......................................0848-062-K ................0848-062-K
Thermometer Kit (Analog) ...................5238-030-K ................5238-030-K
Thermometer Kit (Digital °F) ...............5238-034-K ................5238-034-K
Thermometer °F only .......................5238-034 ....................5238-034
Transformer, 110/220V only ............0759-159 ....................0759-159
Thermometer Kit (Digital °C) ..............5238-034-K1 ..............5238-034-K1
Thermometer °C only .......................5238-034-1 .................5238-034-1
Transformer, 110/220V only ...........0759-159 ....................0759-159
Receptacle .............................................0713-011 ....................0713-012
Switch ...................................................0808-116 ....................0808-116
Cord Set Assembly ...............................0810-031-01 ...............0810-032-01
Cord Holder ..........................................5258-010 ....................5258-010
Pilot Light .............................................0766-094 ....................0766-095
5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
OPERATING and MAINTENANCE INSTRUCTIONS
Model: 120 and 121 Series Proo ng Cabinets
Proo ng
Cabinet
FL-0300-3
Rev. 7 (3/10) Page 4 of 4
SENSOR
OFF
OFF
DIP SWITCH (SW1)
SETTINGS
21 3 1 23
TRANSFORMER
110V/220V
FOR 220V
51
3
8
4
5
2 1
52
50
51
50
SENSOR
TRANSFORMER
110V/220V
FOR 120V
8
4
51
5
3 21
L6-15P PLUG
240V, 15A
L5-20P PLUG
120V, 20A
50
21
34
35
4
THERMOSTAT
HEATER
A
YX
GG
BW
OPTIONAL
51
50
LEGEND
AAmber “Power Light”
ELECTRICAL SPECS.
Model 0747-042 Series
1000W, 120V, 60 Hz, 1Ph
Model 0747-043 Series
900W, 240V, 60 Hz, 1Ph
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Cres Cor 121-1816B 240 Operating instructions

Category
Car kits
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI