ENVIRONMENTAL SPECIFICATIONS
Operating Temperature .......................................................................................................................................................................... -25 º C to 60 º C
Humidity ............................................................................................................................................................................... 0 to 95% Non-Condensing
Power Supply ..........................................................................................................................................................................................+12 or +24 VDC
Power Usage ............................................................................................................................................................................................ 6 Watts typical
Power Supply .......................................................................................................................................................................................Generator Battery
Communication Line .......................................................................................................................... RS485 fully isolated twisted pair cable with shield
Maximum Cable Length .................................................................................................................................................................................... 4000 feet
Relay Output .............................................................................One NO contact (Engergized when annunciator is powered and no faults are present)
Relay Contact Rating .............................................................................................................................................................................. 30 VDC, 1 amp
STANDBY GENERATOR ACCESSORIES
21 Light Remote Annunciator
Liquid-Cooled Generator Sets
Model 5465
Model 5466
Model 5464
The Remote Annunciator Panel provides remote monitoring and
annunciation of up to 18 generator parameters using LED’s located on
the annunciator keypad. It also provides two system level warnings which
are System Ready and Communications OK.
The Relay panel has up to 8 selectable functions on form A relays,
and multiple relay panels can be connected for all 18 generator
parameters.
The specific faults can be selected using either the DIP switches located
on the annunciator circuit board or through a computer via the RS232
connection on the circuit board. All relays are energized on power up and
open during a fault condition.
Communication is via a RS485 serial data link and power is supplied by
the generator battery (+12 VDC or +24 VDC)
Note: These units are only compatible with the H-series generator
controller (70-150 kW)
DESCRIPTION
Specifications
Surface Mount Annunciator
21 Light Remote Annunciator
Flush Mount Annunciator
Function Color Alarm Latched
Pre-Low Oil Pressure Yellow
n
Yes Yes
Pre-High Water Temp Yellow
n
Yes Yes
Pre Low Water Temp Yellow
n
Yes Yes
Pre-Low Fuel Yellow
n
Yes Yes
Battery Charge AC Fail Yellow
n
Yes No
Low Battery Voltage Yellow
n
Yes No
High Battery Voltage Yellow
n
No No
Not in Auto Red
n
Yes No
RPM Sensor Loss Red
n
Yes Yes
Overcrank Red
n
Yes Yes
Overspeed Red
n
Yes Yes
Low Oil Pressure Red
n
Yes Yes
Hi Water Temp Red
n
Yes Yes
Low Water Level Red
n
Yes Yes
Emergency Stop Red
n
Yes No
Gen Running Yellow
n
No No
Gen Power (ATS) Yellow
n
No No
Line Power (ATS) Green
n
No No
Systems Ready Green
n
Yes No
Communications OK Green
n
Yes No
Spare Green
n
No No
Spare Keypad Switch - Can be used to implement a remote start function. (Model 5464 only)
5.8
4.530.812 Dia.
0.812 Dia.
Both sides
0.86
9.06 1.64
2.32
6.49
11.42
8.27
9.64
Outside
Cut
Rough Opening
6.75 " x 9.88 "
Four mounting holes for
21 Light Annunciator
4-mm -0.7 Female Thread
1.57
Thru
R0.59
Both Sides
1.93
10.24
7.09
1.21
1.42
0.87
The 21-Light Annunciator can mount to
a flat surface with connections through
the 0.812 Dia. knockout on the back
surface or through 0.812 knockouts on
sides as shown.
This Flush Mount Box is recessed
into the wall opening and the sur-
face mount annunciator mounts to
the (4) 4 mm screw holes on the
back surface. After wire connec-
tions are made the front annuncia-
tor cover is attached.
Generac Power Systems, Inc. • P.O. Box 297, Whitewater, WI 53190 • guardiangenerators.com
©2008 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0177350SBY/Printed in U.S.A. 04.08, rev. 05.08
  • Page 1 1
  • Page 2 2

Generac Power Systems 5464 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI