Volvo Trucks MID 146 User manual

Type
User manual
Service Manual
Trucks
Group 87
Fault Codes, Climate Control
MID 146
CU-BAS, CU-MCC, CU-ECC
VN, VHD VERSION2
PV776-TSP196483
Foreword
The descriptions and service procedures contained in this manual are based on designs
and methods studies carried out up to October 2003.
The products are under continuous development. Vehicles and components produced
after the above date may therefore have different specifications and repair methods.
When this is believed to have a significant bearing on this manual, supplementary
service bulletins will be issued to cover the changes.
The new edition of this manual will update the changes.
In service procedures where the title incorporates an operation number, this is a
reference to an V.S.T. (Volvo Standard Times).
Service procedures which do not include an operation number in the title are for general
information and no reference is made to an V.S.T.
Each section of this manual contains specific safety information and warnings which
must be reviewed before performing any procedure. If a printed copy of a procedure is
made, be sure to also make a printed copy of the safety information and warnings that
relate to that procedure. The following levels of observations, cautions and warnings
are used in this Service Documentation:
Note: Indicates a situation, handling or circumstance which should be observed.
Caution: Indicates a potentially hazardous situation which, if not avoided, may result in
minor or moderate injury or damage to property.
Warning: Indicates a potentially hazardous situation which, if not avoided, could result
in death, serious injury or major damage to property.
Danger: Indicates an imminently hazardous situation which, if not avoided, will result in
death or serious injury.
Volvo Trucks North America, Inc.
Greensboro, NC USA
Order number: PV776-TSP196483
Repl: This Service Manual replaces Service Manual 87, “Fault Codes, Climate Control MID 146” (11.2002), publication
number PV776–TSP177273 and Service Bulletin 870–14, “Fault Codes, Climate Control MID 146, New Tool, 84105675”
(08.2003), publication number PV776–TSP194734
© 2003 Volvo Trucks North America, Inc., Greensboro, NC USA
All rights reserved. No part of this publication may be reproduced, stored in
retrieval system, or transmitted in any forms by any means, electronic,
mechanical, photocopying, recording or otherwise, without the prior written
permission of Volvo Trucks North America, Inc..
USA14332
Contents
Specifications.........................................................................................3
ClimateUnit,SignalDescription............................................................3
Tools........................................................................................................7
SpecialEquipment.................................................................................7
Troubleshooting.....................................................................................9
MID146FaultCodeTable.....................................................................9
MID146SID2TemperatureSensor,Evaporator................................11
MID146SID2TemperatureSensorEvaporator,Check.....................12
MID146SID5StepperMotor,FreshAirandRecirculation................14
MID146SID5StepperMotorFreshAir-recirculation,Check.............15
MID146SID6StepperMotor,AirDistribution....................................16
MID146SID6StepperMotorAirDistribution,Check.........................17
MID146SID9StepperMotor,AirMix.................................................18
MID146SID9StepperMotor,AirMix/HeatControl,Check..............19
MID146SID11SolenoidClutch,Compressor...................................20
MID146SID12WaterControlValve..................................................21
MID146SID12WaterControlValve,Check......................................22
MID146SID13TemperatureSensor,HeatExchanger......................24
MID146SID13TemperatureSensorHeatExchanger,Check...........25
MID146SID14CirculationFan,TemperatureSensor,Cab...............27
MID146SID15EngineFanRequest..................................................28
MID146SID16StepperMotor,Phase1............................................29
MID146SID16StepperMotorPhase1,Check.................................30
MID146SID17StepperMotor,Phase2............................................31
MID146SID17StepperMotorPhase2,Check.................................32
MID146SID18StepperMotor,Phase3............................................33
MID146SID18StepperMotorPhase3,Check.................................34
MID146SID19StepperMotor,Phase4............................................35
MID146SID19StepperMotorPhase4,Check.................................36
MID146SID22PressureSensor,Refrigerant....................................37
MID146SID22PressureSensorRefrigerantHighPressureSide,
Check..................................................................................................38
MID146SID2325VoltSupplySensors.............................................40
MID146SID2325VoltSupplySensors,Check.................................41
MID146SID250J1708InformationLink............................................42
MID146PID170TemperatureSensor,Cab.......................................43
MID146PID170TemperatureSensorCab,Check............................44
MID146PID171TemperatureSensor,AmbientTemperature...........46
OperationNumbers
1
2
Group 87 Climate Control, Fault Codes Specifications
Specifications
Climate Unit, Signal Description
Connection between the control unit and cable harness
T8008833
W8003419
1 BSA (15 pin)
2 BSB (21 pin)
Conditions:
Breakout box 9998699 connected to adapter 9998596
between the control unit and cable harness.
Breakout box 9998699 connected to adapter 9990025
between the control unit and cable harness.
V = direct current voltage (V)
B+ = battery voltage
R = resistance in ohms (
)
Termi-
nal
Signal type
Measurement
points
Nominal value
Other
BSA1 Not connected
BSA2 Not connected
BSA3 Not connected
BSA4 Not connected
BSA5 Sensor cab temperature, signal
voltage
BSA5 - BSB3 V 0–5V
BSA6 Dash Illumination BSA6 - BSA15 V 5 - 12 V 10 - 90 % of B+
BSA7
BSA8 Fan control, signal voltage BSA8 - BSA15 V 0 - 10 V Rotate fan control
knob
3
Group 87 Climate Control, Fault Codes Specifications
Termi-
nal
Signal type
Measurement
points
Nominal value
Other
BSA9 Power supply, ignition key in
driving position
BSA9 - BSA15 V B+
15
BSA10
BSA11 Supply voltage BSA11 - BSA15 V B+
30
BSA12 Magnetic clutch, air
conditioning (A/C) compressor
BSA12 - BSA15 V B+ Engine running
BSA13
BSA14 Fan, sensor cab temperature BSA14 - BSA15 V B+
BSA15 Ground connection BSA15 - Ground V 0VDC
31
BSB1
BSB2 Engine fan control BSB2 - BSA15 V B+ Engine cooling fan
active
BSB3 Ground terminal sensor BSB3 - Ground V 0VDC
BSB4 SAE J1708 Data link B BSB4 - Ground V 0-5VDC
BSB5 SAE J1708 Data link A BSB5 - Ground V 0 - 5V DC
BSB6 Sensor sytem pressure, signal
volts
BSB6 - Ground V 0.5 - 4.5 V DC
BSB7 Stepper motor phase 1 (low)
BSB8 Stepper motor phase 2 (low)
BSB9 Stepper motor phase 3 (low)
BSB10 Stepper motor phase 4 (low)
BSB11 Stepper motor, by pass, signal
voltage
BSB11 - BSB7 - 10 V <10V Stepper motor
active (Rotate
knob)
BSB12 Stepper Motor, Air distribution,
signal voltage
BSB12 - BSB7 - 10 V <10V Stepper motor
active (Rotate
knob)
BSB13 Stepper Motor, recirculation,
signal voltage
BSB13 - BSB7 - 10 V <10V Stepper motor
active (Rotate
knob)
BSB14
BSB15 Engine coolant valve, voltage
supply
BSB15 - BSA15 V B+ Select Max heat
position, Electronic
climate control
(ECC) only
BSB16
BSB17
BSB18 Sensor system pressure,
voltage supply (5v)
BSB18 - BSA15 V 4.5 - 5.5V
BSB19 Temperaturesensorevaporator,
signal voltage
BSB19 - BSA15 V 0-5V
BSB20 Temperature sensor, heat
exchanger, signal voltage
BSB20 - BSA15 V 0-5V
BSB21 Not connected
4
Group 87 Climate Control, Fault Codes Specifications
Connected to the cable harness
T8008832
W8003419
1 BSA (15 pin)
2 BSB (21 pin)
Conditions:
Breakout box 9998699 with adapter 9990025
connected to cable harness.
Breakout box 9998699 with adapter 9998596
connected to cable harness.
Control unit disconnected.
R = resistance in ohms (
)
Termi-
nal
Signal type
Measurement
points
Nominal value
Other
BSA1
BSA2
BSA3
BSA4
BSA5 Sensor cab temperature BSA5 - BSB3 R 12.5 k
20 C (68 F)
BSA6
BSA7
BSA8 Fan control BSA8 - BSA15 R 100 k
BSA9
BSA10
BSA11
BSA12 Magnetic clutch, air
conditioning (A/C) compressor
BSA12 - BSA15 R 6k
5
Group 87 Climate Control, Fault Codes Specifications
Termi-
nal
Signal type
Measurement
points
Nominal value
Other
BSA13
BSA14
BSA15 Ground connection BSA15 - Ground R 0
BSB1
BSB2
BSB3
BSB4
BSB5
BSB6 Sensor, system pressure BSB6 - BSB3 R 2
R 6
R 10
R 15
2 bar
9 bar
18 bar
30 bar
BSB7
BSB8
BSB9
BSB10
BSB11
BSB12
BSB13
BSB14
BSB15 Engine coolant valve, voltage
supply
BSB15 - BSA11 R 50 FuseF32, removed
BSB16
BSB17
BSB18 Sensor, system pressure BSB18 - BSB3 R 112 k 4.5 bar
BSB19 Temperature sensor evaporator BSB19 - BSB3 R 3.5 k
20 C (68 F)
BSB20 Temperature sensor heat
exchanger
BSB20 - BSB3 R 12.5 k
20 C (68 F)
BSB21 Not connected
6
Group 87 Climate Control, Fault Codes Tools
Tools
Special Equipment
For special tools and other special equipment ordering instructions, see tool information
in group 08.
Special tools
9990025 9998534 9998596
AC Adapter 4 pin DIN adapter AC Adapter
9998699
Breakout box
7
Group 87 Climate Control, Fault Codes Tools
Other special equipment
85105675 85104410 J-39200
Overlay used with 9998596 Overlay used with 9990025 Digital Multimeter
8
Group 87 Climate Control, Fault Codes Troubleshooting
Troubleshooting
MID 146 Fault Code Table
MID:
Message Identification Description (identification of
control unit).
PID:
Parameter Identification Description (identification of
parameter (Value)).
PPID:
Proprietary Parameter Identification Description (Volvo
unique identification of parameter (value)).
SID:
Subsystem Identification Description (identification of
component).
PSID:
Proprietary Subsystem Identification Description
(Volvo-unique identification of component).
FMI:
Failure Mode Identifier (identification of fault type).
For more detailed information concerning these
designations, see service information group 0 ”Vehicle
Electronics ’98”.
Fault code
Component / function
FMI
Section
MID 146 SID 2 Temperature sensor, evaporator
3. 4
“MID 146 SID 2 Temperature
Sensor, Evaporator” page 11
MID 146 SID 5 Stepper Motor, Fresh Air and Recirculation
4
“MID 146 SID 5 Stepper Motor,
Fresh Air and Recirculation” page
14
MID 146 SID 6 Stepper motor, air distribution
4
“MID 146 SID 6 Stepper Motor,
Air Distribution” page 16
MID 146 SID 9 Stepper motor, air mixture (ECC), heat
control (MCC, BAS)
4
“MID 146 SID 9 Stepper Motor,
Air Mix” page 18
MID 146 SID 11 Magnetic clutch, air conditioning (A/C)
compressor
4
“MID 146 SID 11Solenoid Clutch,
Compressor” page 20
MID 146 SID 12 Solenoid valve, water control
3
“MID 146 SID 12 Water Control
Valve” page 21
MID 146 SID 13 Temperature sensor, heat exchanger
3. 4
“MID 146 SID 13 Temperature
Sensor, Heat Exchanger” page
24
MID 146 SID 14 Circulation fan, temperature sensor, cab
4
“MID 146 SID 14 Circulation Fan,
Temperature Sensor, Cab” page
27
MID 146 SID 15 Fan connection, engine
3
“MID 146 SID 15 Engine Fan
Request” page 28
MID 146 SID 16 Stepper motor, phase 1
3
“MID 146 SID 16 Stepper Motor,
Phase 1” page 29
MID 146 SID 17 Stepper motor, phase 2
3
“MID 146 SID 17 Stepper Motor,
Phase 2” page 31
MID 146 SID 18 Stepper motor, phase 3
3
“MID 146 SID 18 Stepper Motor,
Phase 3” page 33
MID 146 SID 19 Stepper motor, phase 4
3
“MID 146 SID 19 Stepper Motor,
Phase 4” page 35
MID 146 SID 22 Pressure sensor, refrigerant, high pressure
side
3. 4
“MID 146 SID 22 Pressure
Sensor, Refrigerant” page 37
MID 146 SID 232 5 volts supply to the sensor
4
“MID 146 SID 232 5 Volt Supply
Sensors” page 40
9
Group 87 Climate Control, Fault Codes Troubleshooting
Fault code
Component / function
FMI
Section
MID 146 SID 250 SAE J1708 data link
9
“MID 146 SID 250 J1708
Information Link” page 42
MID 146 PID 170 Cab, temperature sensor
3. 4
“MID 146 PID 170 Temperature
Sensor, Cab” page 43
MID 146 PID 171 Temperature sensor, outer temperature
3. 4
“MID 146 PID 171 Temperature
Sensor, Ambient Temperature”
page 46
FMI table
SAE standard
FMI Display text
SAE text
0
Value too high Data applicable, but above normal operating range.
1
Value too low Data applicable, but below normal operating range.
2
Incorrect data Intermittent or incorrect data.
3
Electrical fault Abnormally high voltage or short-circuit to higher voltage.
4
Electrical fault Abnormally low voltage or short-circuit to lower voltage.
5
Electrical fault Abnormally low current or open-circuit.
6
Electrical fault Abnormally high current or short-circuit to ground.
7
Mechanical fault Incorrect response from the mechanical system.
8
Mechanical or
electrical fault
Abnormal frequency.
9
Communication fault Abnormal update rate.
10
Mechanical or
electrical fault
Abnormally high variations.
11
Unknown fault Unidentifiable fault.
12
Component fault Defective unit or component.
13
Incorrect calibration Calibration values outside the limits.
14
Unknown fault Special instructions.
15
Unknown fault Reserved for future use.
10
Group 87 Climate Control, Fault Codes Troubleshooting
MID 146 SID 2 Temperature Sensor, Evaporator
T8008634
T8008560
Component:A34 Climate Control Unit, E32 Climate
Unit
General information
The sensor measures the air temperature after the
evaporator and before the blower fan. The temperature
signal is used to protect the evaporator against icing
by engaging and disengaging the compressor. The
compressor is disengaged at approximately 3
C (37 F)
and engages at approximately 8
C (46 F).
Fault code
FMI 3
Abnormally high voltage or short-circuit to higher voltage.
Conditions for fault code:
If the control unit detects a voltage higher than
4.86 volts the control unit interprets this as an error
and a fault code is stored.
Possible cause:
Connector to sensor disconnected
Signal cable short-circuited to higher voltage
Ground lead short-circuited to higher voltage
Reaction from the control unit:
Fault code is stored
Yellow lamp requested
Noticeable external symptoms:
Yellow lamp lights up
The compressor "cycles" 20 s active, 60 s inactive
Appropriate check:
See “MID 146 SID 2 Temperature Sensor Evaporator,
Check” page 12
FMI 4
Abnormally low voltage or short-circuit to lower voltage
Conditions for fault code:
If thecontrol unit detectsa voltage lower than 0.24 volts
the control unit interprets this as an error and a fault
code is stored.
Possible cause:
Signal cable short-circuited to ground
Reaction from the control unit:
Fault code is stored
Yellow lamp requested
Noticeable external symptoms:
Yellow lamp lights up
The compressor "cycles" 20 s active, 60 s inactive
Appropriate check:
See “MID 146 SID 2 Temperature Sensor Evaporator,
Check” page 12
11
Group 87 Climate Control, Fault Codes Troubleshooting
8730-21-02-01
MID 146 SID 2 Temperature Sensor Evaporator, Check
Special tools: 9990025, 9998699
Other special equipment: J-39200
NOTE
Check all relevant connectors. Check for loose
connections, contact resistance and oxidation. For a
more detailed description of fault-tracing wiring
and connectors, see separate service information
under Group 371.
Measurement at the component
connector to the control unit
Note: If one of the values below is incorrect this may also
have caused the component to fail, check the component
if any of the values are incorrect.
Ground lead
1
Conditions:
Measuring voltage using the J-39200 Digital
Multimeter.
Ignition key in the drive position.
Measurement to the control unit.
Control unit connected.
Measurement points Nominal value
BSB3 - Ground V 0V
J-39200
9998699
, 9990025
12
Group 87 Climate Control, Fault Codes Troubleshooting
Signal cable
2
Conditions:
Measuring voltage using the J-39200 Digital
Multimeter.
Engine with increased idle speed approx. 1000 rpm.
Measurement to the control unit.
Control unit connected.
Air conditioning (A/C) system active.
Measurement points Nominal value
BSB3 - BSB19
V 3.64 - 3.85 V (-10 C,
14
F)
V 1.94 - 2.10 V (20
C,
68
F)
V 1.06 - 1.18 V (40
C,
104
F)
J-39200
9998699
, 9990025
Checking component
3
Conditions:
The component connector disconnected.
Measuring resistance using a J-39200 Digital
Multimeter.
Measurement to the component.
Measurement
points
Nominal value
1-2
R 14.92 - 15.51 k
(-10 C, 14 F)
1-2
R 3.37 - 3.53 k
(20 C, 68 F)
1-2
R 1.43 -1.51 k (40 C,
104
F)
1 - ground Open circuit
2 - ground Open circuit
J-39200
13
Group 87 Climate Control, Fault Codes Troubleshooting
MID 146 SID 5 Stepper Motor, Fresh Air and Recirculation
T8008643
T8008561
Component: A34 Climate Control Unit, E32 Climate
unit
General information
The stepper motor opens and closes the shutter for the
fresh air and recirculation. The stepper motor is located
on the front edge of the climate control unit.
Fault code
FMI 4
Abnormally low voltage or short-circuit to lower voltage
Conditions for fault code:
If the control unit detects a short-circuit to ground, the
control unit interprets this as an error and a fault code
is stored.
Possible cause:
Signal cable to stepper motor Fresh air /Recirculation
short-circuited to lower voltage
Signal cable to stepper motor Fresh air /Recirculation
short-circuited to ground
Reaction from the control unit:
Fault code is stored
Yellow lamp requested
Noticeable external symptoms:
Yellow lamp lights up
No control of Fresh air / Recirculation SID 5
Appropriate check:
See “MID 146 SID 5 Stepper Motor Fresh
Air-recirculation, Check” page 15
14
Group 87 Climate Control, Fault Codes Troubleshooting
8730-21-02-02
MID 146 SID 5 Stepper Motor Fresh Air-recirculation, Check
Special tools: 9990025, 9998699
Other special equipment: J-39200
NOTE
Check all relevant connectors. Check for loose
connections, contact resistance and oxidation. For a
more detailed description of fault-tracing cables and
connectors, see service information group 371.
Measurement at the component
connector to the control unit
Note: If one of the values below is incorrect this may also
have caused the component to fail, check the component
if any of the values are incorrect.
Signal cable
1
Conditions:
Control unit connected.
Measuring voltage using the J-39200 Digital
Multimeter.
Ignition key in the drive position.
Measurement to the control unit.
Stepper motor active.
Measurement points Nominal value
BSB13 - BSB7 V <10V
BSB13 - BSB8 V <10V
BSB13 - BSB9 V <10V
BSB13 - BSB10 V <10V
Note: If the measurement value exceeds 10 V there is
probably an open circuit in the cable to the stepper motor.
J-39200
9990025
, 9998699
15
Group 87 Climate Control, Fault Codes Troubleshooting
MID 146 SID 6 Stepper Motor, Air Distribution
T8008643
T8008562
Component: A34 Climate Control Unit, E32 Climate
unit
General information
The stepper motor controls the air distribution in the
cab. The stepper motor is located on the left side on the
climate control unit.
Fault code
FMI 4
Abnormally low voltage or short-circuit to lower voltage
Conditions for fault code:
If the control unit detects a short-circuit to ground, the
control unit interprets this as an error and an fault code
is stored.
Possible cause:
Signal cable to air distribution stepper motor short
circuited to lower voltage
Signal cable to air distribution stepper motor short
circuited to ground
Reaction from the control unit:
Fault code is stored
Yellow lamp requested
Noticeable external symptoms:
Yellow lamp lights up
No control of Fresh air / Recirculation SID 6
Appropriate check:
See “MID 146 SID 6 Stepper Motor Air Distribution,
Check” page 17
16
Group 87 Climate Control, Fault Codes Troubleshooting
8730-21-02-03
MID 146 SID 6 Stepper Motor Air Distribution, Check
Special tools: 9990025, 9998699
Other special equipment: J-39200
NOTE
Check all relevant connectors. Check for loose
connections, contact resistance and oxidation. For a
more detailed description of fault-tracing cables and
connectors, see service information group 371.
Measurement at the component
connector to the control unit
Note: If one of the values below is incorrect this may also
have caused the component to fail, check the component
if any of the values are incorrect.
Signal cable
1
Conditions:
Control unit connected.
Measuring voltage using the J-39200 Digital
Multimeter.
Ignition key in the drive position.
Measurement to the control unit.
Control unit connected.
Stepper motor active.
Measurement points Nominal value
BSB12 - BSB7 V <10V
BSB12 - BSB8 V <10V
BSB12 - BSB9 V <10V
BSB12 - BSB10 V <10V
Note: If the measurement value exceeds 10V there is
probably an open circuit in the cable to the stepper motor.
J-39200
9998699
, 9990025
17
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52