Unites KERBEROS POWER 6000.B Installation guide

Type
Installation guide
KERBEROS POWER
KERBEROS POWER 6000.B
INSTALLATION MANUAL
KERBEROS POWER
INSTALLATION
CONNECTION................................................................................................................................................................................... 6
................................................................................................................................................................................. 5
PUTTING INTO OPERATION.......................................................................................................................................................... 12
TECHNICAL PARAMETERS.............................................................................................................................................................. 13
CERTIFICATION................................................................................................................................................................................ 14
EN
ASSEMBLING ................................................................................................................................................................................. 4
KERBEROS POWER
3
EN
Actual versions of manuals you can find on www.solar-kerberos.com/en/downloads
EN
KERBEROS POWER
Due to the safety of the goods during transport,
Kerberos POWER is distributed partially
dismantled. Depending on the configuration,
one, two or three power modules must be
inserted into the frame. They look the same,
they differ only with an address that is set by two
jumper - see pictures.
Connect the fan cables to the X1 connectors
on the power modules and screw the covers. !
Be careful to place the light guide when
installing the covers!
!!! Connect
Plug the power modules carefully into their
respective rails and push in tightly to connect
the connectors properly.
grren/yellow
grounding
cable!!!
4
1. ASSEMBLING
EN
KERBEROS POWER
290 mm
230 mm
When installing the KERBEROS POWER, it is
necessary to take into account the working
conditions in which it can work (see chapter
Technical parameters of the user manual). It is
also necessary to consider the sound of the
inverter (especially the cooling fans).
- Screw the screws leaving about one
centimeter protruding from the dowel.
- Hang KERBEROS POWER on the screws.
WARNING, the permissible wall unevenness is
± 2mm!
- Tighten the screws gently.
WARNING, do not install in humidity
condensing room (see chapter Technical Data
of the User Manual)
Wall Mounting:
- Refer to the drawing for drilling holes for
dowels / screws. The enclosed drilling
template will help you with work.
- Drill the holes and insert the dowels
enclosed. If the wall material requires different
type of anchors, use it (plasterboard, hollow
brick, etc.).
!
When drilling, installing
rails and similar activities,
protect KERBEROS
POWER from dust!
5
2. INSTALLATION
EN
KERBEROS POWER
1. Connect photovoltaic panels to overvoltage protection switchboard.
Connect to the grid. Ensure that the PV fuse switch and AC circuit breaker are
in the off state. WARNING, the cables from the PV panels can be dangerous
even in a little sunshine!
Installation may only be
carried out by a qualified
person, in compliance with
all occupational safety
rules
AC
breaker
6A
10A10A10A
IN1
IN2
IN3
PE
N
L
Earthing system
Overvoltage
protection
B+C Panels 1
Panels 2
Panels 3
6
3. CONNECTION
EN
KERBEROS POWER
2. Unscrew the bottom cover - be careful - it is connected through the Faston
connector to the protective jumper wire! Disconnect it and reconnect it before
reassembling the cover!
7
3. CONNECTION
EN
Installation may only be
carried out by a qualified
person, in compliance with
all occupational safety
rules
KERBEROS POWER
3. Provide the cables with the crimp terminals before connecting them to the
terminal blocks.
crossing. After connecting
4. Guide the cables through the
grommets avoiding unnecessary
the grommets well.
the cables tighten swivel nuts of
Terminal of
thermostat
temperature
sensors and
thermal fuses
Mains terminal
block
Output of heating
element 1
Output of heating
element 3
Output of heating
element 2
Input of PV panels
group 3
Input of PV panels
group 1
Input of PV panels
group 2
3. CONNECTION
8EN
Installation may only be
carried out by a qualified
person, in compliance with
all occupational safety
rules
KERBEROS POWER
Panels 1
Panels 2
Panels 3Heating element 2
Heating
element 3
Heating
element 1
Mains
Thermostat
Termal
fuse
5. Plug the inlets from photovoltaic panels, heater outputs, mains supply and
sensors of both thermal fuse and thermostat.
3. CONNECTION
9EN
KERBEROS POWER
3. CONNECTION
10
6. Recommended minimum cross-sections of cables:
Grounding cable: 4mm2
Inlet from PV panels : 2.5mm2
Outlet to boiler heater: 2.5mm2
Mains inlet: 1.5mm2
Thermal probe extension: 0.25mm2
7. Insert both thermostat sensor and thermal fuse concurrently (or one dual
sensor) into storage reservoir tank / boiler so that they are secured against
ejecting. If necessary, you can extend the cables to the sensors by means of the
enclosed terminal block and conductors with a cross section of at least 0.25
mm2.
Thermal sensors for thermostat and thermal fuse are identical and can be
supplied like tvo separate sensors or one double sensor (two sensors in one
housing)
EN
Wiring of double - sensor
KERBEROS POWER
3. CONNECTION
11
8. Connect the heating element (elements) by min. 2.5 mm2 cross-section
wires. If you use a three-phase heating element, it must have separate sections!
Heating element
section 1
Heating element
section 2
Heating
element section 3
EN
Installation may only be
carried out by a qualified
person, in compliance with
all occupational safety
rules
KERBEROS POWER
2.Using fuse switches connect one by one all the groups of PV panels to
KERBEROS POWER.
1. After checking the wiring, turn on the mains circuit breaker.
3. Check the KERBEROS POWER function
5. If everything is OK, cover the bottom of KERBEROS POWER. Do not forget
connecting protective conductor wire to the housing!
4.Test the safety circuits of KERBEROS POWER by disconnecting the
temperature sensors of the thermostat and thermal fuse.
6. Instruct the user in safe use of KERBEROS POWER!
4. PUTTING INTO OPERATION
12 EN
KERBEROS POWER
5. TECHNICAL PARAMETERS
13 EN
Electric data of one photovoltaic power module*
Electric data - mains electricity
Input voltage 230 V AC 50 Hz
Power consumption < 5W
Heating elements
Thermal regulator
Setting range 10 - 85°C
Thermal fuse YES - electronic
Working conditions
Operating temperature +5 až +40°C
Storage temperature -10 až +40°C
Operating relative humidity Max 75 % non condensing
Storage relative humidity Max 90 % non condensing
Environmental dustiness
Chemical influence Non aggressive
Construction parameters
Measurements (height x width x depth)
Weight
Ingress protection
Dust particles volume max 0,75 mg/m³
Input open circuit voltage (limits) 200 - 340 VDC
MPP tracking range 185 - 320 VDC
Maximum output current 9 A
Maximum efficiency 99 %
Typical wiring 8 x 260 Wp**
11,2 kg
IP 20
498 x 210 x 270 mm
WiFi / Ethernet communication module (optional)
Measurement period
The performance of heater / section
Number of heating elements or independent sections 1 - 3 pc
2 - 2,5 kW
The possibility of using a three-phase body with separate sections YES
The possibility of using separate single phase heating elements YES
The possibility of using a three phase body with a common center NO
60 sec
History of data recording 365 days
** Different number of PV modules and different module power than recomended are feasible but
maximum input voltage must be strictly kept at any solar irradiation and temperature.
* KERBEROS POWER can be equipped with 1, 2 or 3 power modules
Number of power modules 1 - 3 pc
KERBEROS POWER
6. CERTIFICATION
14 EN
KERBEROS POWER
EN
UNITES Systems a.s.
Kpt. Macha 1372
Valašské Meziříčí
Czech Republic
info@solar-kerberos.cz
www.unites-systems.com
www.solar-kerberos.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

Unites KERBEROS POWER 6000.B Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI