5Energyvisualisation
Operationmanual
9
EHYHBH05AA+EHYHBH/X08AA
DaikinAlthermahybridheatpump
4P3495881–2013.05
INFORMATION
Price value ranging from 0.00~990 valuta/kWh (with 2
significantvalues).
4.3 Tosettheelectricityprice
scheduletimer
1Goto[7.3.8]: >Usersettings>Setschedules>Elecprice.
2ProgramthescheduleaccordingtotheHigh,MediumandLow
electricitypricesforeachtimeinterval.
3Press tosavetheschedule.
INFORMATION
ThevaluesforHigh,MediumandLowcorrespondwiththe
electricity price values for High, Medium and Low
previouslyset.Ifnoscheduleisset,theelectricitypricefor
Highistakenintoaccount.
5 Energyvisualisation
Theuserinterfaceisabletographicallydisplayenergystatisticsfor:
▪ producedenergy:energyproducedbytheheatpump.
▪ consumed electricity: recorded by an electricity meter or, when
none is installed, calculated by the interface itself based on an
internalcalculation.
▪ consumed gas: only recorded when an external gas meter is
installed. Note that the values recorded by the meter may differ
fromthoseshownontheboiler.
5.1 Toviewtheenergystatistics
1Goto[6.2]: >Information>Energymetering.
2SelecteitherConsumedelec.,>ProducedenergyorConsumed
gas.
3Use the and buttons to toggle between views of the
current month, the previous month, the last 12 months and a
generaloverview.
4Usethe and buttonstotogglebetweendifferentmodes
(ifapplicable).
6 Energysavingtips
Tipsaboutroomtemperature
▪ Makesure the desired room temperature is NEVER toohigh (in
heating mode) or too low (in cooling mode), but ALWAYS
accordingtoyouractualneeds.Eachsaveddegreecansaveup
to6%ofheating/coolingcosts.
▪ Do NOT increase the desired room temperature to speed up
spaceheating.ThespacewillNOTheatupfaster.
▪ When your system layout contains slow heat emitters (example:
under floor heating), avoid large fluctuation of the desired room
temperatureanddoNOTlettheroomtemperaturedroptoolow.It
willtakemoretimeandenergytoheatuptheroomagain.
▪ Useaweeklyscheduleforyournormalspaceheatingorcooling
needs.Ifnecessary,youcaneasilydeviatefromtheschedule:
▪ For shorter periods: You can overrule the scheduled room
temperature. Example: When you have a party, or when you
areleavingforacoupleofhours.
▪ For longer periods: You can use the holiday mode. Example:
When you stay at home during your holiday, or when you go
awayduringyourholiday.
TipsaboutDHWtanktemperature
▪ Makesurethenumber(availablehotwaterforxpersons)onthe
DHWtanktemperaturehomepageisNOThigherthanyouractual
needs.
▪ Useaweeklyscheduleforyournormaldomestichotwaterneeds
(onlyinscheduledmode).
▪ Programto heat up the DHW tank toa preset value (Storage
comfort = higher DHW tank temperature) during the night,
becausethenspaceheatingdemandislowerandelectrictariffs
maybelower.
▪ If heating up the DHW tank once at night is not sufficient,
programtoadditionallyheatuptheDHWtanktoapresetvalue
(Storageeco=lowerDHWtanktemperature)duringtheday.
▪ Make sure the desired DHW tank temperature is NOT too high.
Example:Afterinstallation,lowertheDHWtanktemperaturedaily
by1°Candcheckifyoustillhaveenoughhotwater.
▪ Program to turn ON the domestic hot water pump only during
periodsofthedaywheninstanthotwaterisnecessary.Example:
Inthemorningandevening.
7 Maintenanceandservice
7.1 Overview:Maintenanceand
service
Theinstallerhastoperformayearlymaintenance.Youcanfindthe
contact/helpdesknumberviatheuserinterface.
Asenduser,youhaveto:
▪ Keeptheuserinterfacecleanwithasoftdampcloth.DoNOTuse
anydetergents.
▪ Regularlycheckifthewaterpressureindicatedonthegasboileris
above1bar.Switchofftheboilertoseethepressureonthemain
displayofthegasboiler.Ignoretheerrorthatappearsontheuser
interface. When you turn the gas boiler back on, the error will
disappear.
Refrigerant
Thisproductcontainsfluorinatedgreenhousegasescoveredbythe
KyotoProtocol.DoNOTventgasesintotheatmosphere.
Refrigeranttype:R410A
Globalwarmingpotentialvalue:1975
Periodical inspections for refrigerant leaks may be required
dependingontheapplicablelegislation.Pleasecontactyourinstaller
formoreinformation.