Aiphone KB-DAR-M Operating instructions

Category
Door intercom systems
Type
Operating instructions
KB-DAR Modified for Motion Detector Interface
- INSTRUCTIONS -
The KB-DAR-M allows any standard motion detector or activation device with a normally open contact to
be interfaced with the KB-3MRD Video System. When the motion detector is tripped, the camera will turn
on and a chime will be heard at the inside monitor station(s), indicating that there is some activity near
the door station location.
WIRING DIAGRAM:
Motion Detector*
* Or any signaling
Pulnix 6612
Ademco 1998PI
Sentrol AP750
Door Strike
PT-1210N
(AC Transformer)
A1
A2
White
KB-DAR-M
White
A1
A2
KB-DAR
+
-
PS-2420UL
1A1
1A2
B2
+
2A1
2A2
B1
-
KB-3MRD
Yel
Org
1A2
+
1A1
-
KB-3HRD
device that provides a
normally open
momentary dry closure.
Aiphone 871802 wire
Aiphone 871802 wire
871802
Motion Detectors with N/O Contacts:
Detection Systems DS720I
Intellisense 8140S
Installation Guidelines:
1. The motion detector must provide a normally open momentary contact
. A Photelectric beam, pressure
pad, or remote call button can also be used to activate the video door station.
2. The KB-DAR-M works with the KB system only. Standard KB-DAR's can be used in the same system if they
are not interfaced with a remote activation device.
Note:
Only information concerning the use of the KB-DAR-M is shown here.
For complete system installation, please refer to the instruction manuals included with the video system.
Aiphone Communication Systems
1700 130th Ave. N.E.
Toll Free Technical Support:
Bellevue, WA 98005
1-800-692-0200
(425) 455-0510
KB-DAR-M Instr.
FAX (425) 455-0071
0703bkjs
Available from A1 Security Cameras
www.a1securitycameras.com email: [email protected]
  • Page 1 1

Aiphone KB-DAR-M Operating instructions

Category
Door intercom systems
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI