Broadcom MegaRAID 8704EM2-8708EM2 User guide

Category
RAID controllers
Type
User guide

This manual is also suitable for

Thank you for purchasing the MegaRAID
®
1078-based SAS
(Serial Attached SCSI/Serial ATA II) 8704EM2 RAID
Controller (PCI-Express) or the SAS 8708EM2 RAID
Controller (PCI-Express).
Note
: The SAS 8704EM2 RAID Controller does not
contain the J8 connector (SAS ports 4-7). This is
the only difference between the SAS 8704EM2
RAID Controller, which supports one connector
and four ports, and the SAS 8708EM2 RAID
Controller, which supports two connectors and
eight ports.
Please take a few minutes to read this quick installation
guide before you install your RAID controller. If you need
more information about any topic covered in this guide, refer
to the related documents on your MegaRAID Universal
Software Suite CD.
Note: SATA II is the only type of SATA supported by
this RAID controller.
You can connect the LSI intelligent Battery Backup Unit 06
(LSIiBBU06) directly to the SAS 8704EM2 RAID Controller
or the SAS 8708EM2 RAID Controller. For more information
about this battery, refer to the Intelligent Battery Backup Unit
for 1078-based MegaRAID Products User’s Guide on the
MegaRAID Universal Software Suite CD.
RAID CONTROLLER INSTALLATION
Step 1 Unpack the RAID Controller
Unpack the RAID controller in a static-free
environment. Remove it from the antistatic bag,
and inspect it for damage. If the RAID controller
appears to be damaged, or if the MegaRAID
Universal Software Suite CD is missing, contact
LSI or your MegaRAID OEM support
representative.
The CD contains utility programs, device drivers
for various operating systems, and the following
documentation:
MegaRAID 1078-based SAS RAID Controllers
User’s Guide
MegaRAID SAS Software User’s Guide
MegaRAID SAS Device Driver Installation
User’s Guide
Intelligent Battery Backup Unit for 1078-based
MegaRAID Products User’s Guide
Software license agreement
Step 2 Prepare the Computer
Turn off the computer, and unplug the power
cords from the rear of the power supply. Remove
the cover from the computer.
Step 3 Review the Jumpers and the Connectors
Figure 1 shows the location of the jumpers and
the connectors on the RAID controller. The
jumpers are set at the factory, and you usually do
not need to change them.
Figure 1 Layout of the MegaRAID SAS 8708EM2
RAID Controller
Back up your data before you change your
system configuration. Otherwise, you might lose
data.
!
CAUTION
Before you install the RAID controller, make sure
that the computer is disconnected from the power
and from any networks.
!
CAUTION
85020-00
J7
J6
Port
3-0
Port
7-4
J8
J12
J9
J5
J1
J10
J4
J3
J2
MegaRAID SAS 8704EM2 RAID Controller
and SAS 8708EM2 RAID Controller
Quick Installation Guide
2 of 3
Table 1 describes the jumpers and the
connectors on the SAS 8704EM2 RAID
Controller and the SAS 8708EM2 RAID
Controller.
Table 1 Jumpers and Connectors
Step 4 Install the RAID Controller
Insert the RAID controller in a PCI Express slot
on the motherboard, as shown in Figure 2. Press
down gently, but firmly, to seat the card correctly
in the slot. Secure the RAID controller to the
computer chassis with the bracket screw.
Note: Refer to the guide for your motherboard for
information about the PCI Express slot.
Note: This is a PCI Express x8 card. It can operate in
x8 or 16x slots.
Figure 2 Installing the MegaRAID SAS 8708EM2
RAID Controller
Step 5 Configure and Install the SAS Devices, SATA
II Devices, or Both in the Host Computer Case
Refer to the documentation for the devices for
any preinstallation configuration requirements.
Jumper/
Connector Type Description
J1 Individual Fault
LED header for
eight ports
16-pin connector.
Indicates physical disk faults.
There is one LED per port. When
lit, each LED indicates the corre-
sponding physical disk has failed
or is in the Unconfigured-Bad
state. Refer to the MegaRAID SAS
Software User’s Guide for more
information about drive states.
1. The LEDs function in a direct-
attach configuration (there are
no SAS expanders). Direct
attach is defined as a maxi-
mum of one physical disk con-
nected directly to each port.
J2 Cache Write Pend-
ing LED
2-pin connector.
The connector for the enclosure
LED. It provides a signal that indi-
cates when the on-board cache
contains data and a write from the
cache to the physical disks is
pending. Optional.
J3 Combined Activity
header
2-pin connector.
Provides an LED interface that
indicates activity on individual
drives attached to the card.
J4 Mode Select
header
2-pin connector.
Reserved for LSI use.
J5 Universal Asyn-
chronous Receiver/
Transmitter (UART)
debugging
4-pin connector.
Reserved for LSI use.
J6 BRK Debug
connector
2-pin header.
Reserved for LSI use.
J7 IPMI-style SMBus
(System Manage-
ment)/I
2
C header
3-pin shielded header.
Provides enclosure management
support.
J8 x8 SAS Ports 4–7
1. The SAS
8704EM2
RAID Control-
ler does not
have this con-
nector.
The x4 SAS connectors connect
the cables from the RAID control-
ler to SAS physical disks, SATA II
physical disks, or a SAS expander.
J9 x8 SAS Ports 0–3 The x4 SAS connectors connect
the cables from the RAID control-
ler to SAS physical disks, SATA II
physical disks, or a SAS expander.
J10 Battery Backup
connector
20-pin connector.
Provides the interface to the bat-
tery backup unit. The LSIiBBU06
connects directly to the RAID
controller.
J12 Reserved for LSI
use.
2-pin connector.
Reserved for LSI use.
Jumper/
Connector Type Description
85020-01
34146-01 Rev. A, January 2008
Find a list of LSI Corporation’s U.S. distributors, international distributors, sales
offices, and design resource centers on the LSI web site at:
http://www.lsi.com
LSI, the LSI logo design, and MyStorage are trademarks or registered trademarks
of LSI Corporation. All other brand and product names may be trademarks of their
respective companies.
Copyright © 2008 by LSI Corporation. All rights reserved.
LSI Corporation reserves the right to make changes to any products and services
herein at any time without notice. LSI does not assume any responsibility or
liability arising out of the application or use of any product or service described
herein, except as expressly agreed to in writing by LSI; nor does the purchase,
lease, or use of a product or service from LSI convey a license under any patent
rights, copyrights, trademark rights, or any other of the intellectual property rights
of LSI or of third parties.
Step 6 Connect the RAID Controller to the SAS
Devices, SATA II Devices, or Both in the Host
Computer Case
Use SAS cables to connect the SAS RAID
controller to SAS devices, SATA II devices, or
both. See Figure 1 to view the connector
locations on the RAID controller.
Refer to the MegaRAID 1078 SAS RAID
Controllers User’s Guide on the MegaRAID
Universal Software Suite CD for detailed
information about the SAS cables.
Step 7 Turn on the Power to the Computer
Reinstall the computer cover, and reconnect the
power cords. Turn on the power to the computer.
Make sure that the power is turned on to the SAS
devices and the SATA II devices before or at the
same time that the power to the host computer is
turned on. If the power is turned on to the
computer before it is turned on to the devices, the
computer might not recognize the devices.
The firmware takes several seconds to initialize.
During this time, the controller scans the ports.
Step 8 Run the WebBIOS Configuration Utility
Run the WebBIOS Configuration Utility to
configure the physical arrays and the logical
drives. When the message Press <Ctrl><H> for
WebBIOS appears on the screen, immediately
press CTRL+H to run the utility.
Note: Refer to the MegaRAID SAS Software User’s
Guide on the MegaRAID Universal Software
Suite CD for detailed steps on configuring
physical arrays and logical drives.
Step 9 Install the Operating System Driver
The RAID controller can operate under various
operating systems, but you must install the
software drivers first.
The MegaRAID Universal Software Suite CD
includes the software drivers for the supported
operating systems, along with documentation.
You can view the supported operating systems
and download the latest drivers for RAID
controllers from the LSI website at: http://
www.lsi.com/cm/DownloadSearch.do. Access the
download center, and follow the steps to
download the driver.
Refer to the MegaRAID SAS Device Driver
Installation User’s Guide on the MegaRAID
Universal Software Suite CD for details on
installing the driver. Be sure to use the latest
service packs that are provided by the operating
system manufacturer and to review the readme
file that accompanies the driver.
SUPPORTED RAID LEVELS
The SAS 8704EM2 RAID Controller and the SAS 8708EM2
RAID Controller support disk arrays using the following RAID
levels:
RAID 0 (data striping): Data is striped across all disks in
the array, enabling very fast data throughput. There is no
data redundancy. All data is lost if any disk fails.
RAID 1 (disk mirroring): Data is written simultaneously
to two disks, providing complete data redundancy if one
disk fails. The maximum array capacity is equal to the
available size of the smaller of the two physical disks.
RAID 5 (disk striping with distributed parity): Data is
striped across all disks in the array. Part of the capacity
of each disk stores parity information that reconstructs
data if a disk fails. RAID 5 provides good data throughput
for applications with high read request rates.
RAID 6 (disk striping with distributed parity across
two disks): Data is striped across all disks in the array
and two parity disks are used to provide protection
against the failure of up to two physical disks. In each row
of data blocks, two sets of parity data are stored.
RAID 10 (RAID 1 and RAID 0 in spanned arrays): RAID
10 uses mirrored pairs of disks to provide complete data
redundancy. RAID 10 provides high data throughput
rates.
RAID 50 (RAID 5 and RAID 0 in spanned arrays): RAID
50 uses both parity and disk striping across multiple disks
to provide complete data redundancy. RAID 50 provides
high data throughput rates.
RAID 60 (RAID 6 and RAID 0 in spanned arrays): RAID
60 uses both distributed parity across two parity disks and
disk striping across multiple disks to provide complete
data redundancy. RAID 60 provides high fault tolerance.
TECHNICAL SUPPORT
For assistance in installing, configuring, or running your SAS
RAID controller, contact LSI Technical Support.
Phone Support: 1-800-633-4545 (North America)
Web Site: http://www.lsi.com/support
  • Page 1 1
  • Page 2 2
  • Page 3 3

Broadcom MegaRAID 8704EM2-8708EM2 User guide

Category
RAID controllers
Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI