Spectrum Controls 140 AUI 040 00sc Owner's manual

Type
Owner's manual

This manual is also suitable for

User’s Manual Pub. 0300316-01 Rev. C
User’s Manual Pub. 0300316-01 Rev. C
Important Notes 1. Please read all the information in this owner’s guide before installing the
product.
2. The information in this owner's guide applies to hardware Series A and
firmware version 1.00 or later.
3. This guide assumes that the reader has a full working knowledge of the
relevant processor.
Notice
The products and services described in this owner's guide are useful in a wide
variety of applications. Therefore, the user and others responsible for applying
the products and services described herein are responsible for determining their
acceptability for each application. While efforts have been made to provide
accurate information within this owner's guide, Spectrum Controls, Inc. assumes
no responsibility for the accuracy, completeness, or usefulness of the information
herein.
Under no circumstances will Spectrum Controls, Inc. be responsible or liable for
any damages or losses, including indirect or consequential damages or losses,
arising out of either the use of any information within this owner's guide or the
use of any product or service referenced herein.
No patent liability is assumed by Spectrum Controls, Inc. with respect to the use
of any of the information, products, circuits, programming, or services referenced
herein.
The information in this owner's guide is subject to change without notice.
Limited Warranty
Spectrum Controls, Inc. warrants that its products are free from defects in
material and workmanship under normal use and service, as described in
Spectrum Controls, Inc. literature covering this product, for a period of 1 year.
The obligations of Spectrum Controls, Inc. under this warranty are limited to
replacing or repairing, at its option, at its factory or facility, any product which
shall, in the applicable period after shipment, be returned to the Spectrum
Controls, Inc. facility, transportation charges prepaid, and which after
examination is determined, to the satisfaction of Spectrum Controls, Inc., to be
thus defective.
This warranty shall not apply to any such equipment which shall have been
repaired or altered except by Spectrum Controls, Inc. or which shall have been
subject to misuse, neglect, or accident. In no case shall the liability of Spectrum
Controls, Inc. exceed the purchase price. The aforementioned provisions do not
extend the original warranty period of any product which has either been repaired
or replaced by Spectrum Controls, Inc.
User’s Manual Pub. 0300316-01 Rev. C
Table of Contents
IMPORTANT NOTES ............................................................................................................................................... II
LIMITED WARRANTY .............................................................................................................................................. II
CHAPTER 1 MODULE OVERVIEW ......................................................................................................................... 1-1
SECTION 1.1 GENERAL DESCRIPTION .............................................................................................................................. 1-2
SECTION 1.2 INPUT TYPES ............................................................................................................................................ 1-2
SECTION 1.3 DATA FORMATS ....................................................................................................................................... 1-3
SECTION 1.4 FILTER FREQUENCIES ................................................................................................................................ 1-3
SECTION 1.5 HARDWARE FEATURES .............................................................................................................................. 1-3
1.5.1 LED Indicators ........................................................................................................................................... 1-5
SECTION 1.6 SYSTEM OVERVIEW ................................................................................................................................... 1-6
1.6.1 Module Power-up ..................................................................................................................................... 1-6
1.6.2 Module Operation ..................................................................................................................................... 1-6
CHAPTER 2 INSTALLATION AND WIRING ............................................................................................................. 2-1
SECTION 2.1 COMPLIANCE TO EUROPEAN UNION DIRECTIVES ............................................................................................. 2-1
2.1.1 EMC Directive ............................................................................................................................................ 2-1
2.1.2 ATEX Directive ........................................................................................................................................... 2-1
SECTION 2.2 POWER REQUIREMENTS ............................................................................................................................ 2-2
SECTION 2.3 GENERAL CONSIDERATIONS ........................................................................................................................ 2-2
2.3.1 Hazardous Location Considerations .......................................................................................................... 2-2
2.3.1 Prevent Electrostatic Discharge ................................................................................................................ 2-3
2.3.2 Remove Power .......................................................................................................................................... 2-3
2.3.3 Selecting a Location .................................................................................................................................. 2-3
SECTION 2.4 MOUNTING ............................................................................................................................................. 2-4
2.4.1 Before You Begin ....................................................................................................................................... 2-4
2.4.2 Install Mounting Base ............................................................................................................................... 2-5
2.4.3 Install the I/O Module ............................................................................................................................... 2-5
2.4.4 Install the Removable Terminal Block (RTB) ............................................................................................. 2-7
2.4.5 Remove a Mounting Base ......................................................................................................................... 2-7
2.4.6 Install a 1734-TOPS Base .......................................................................................................................... 2-7
2.4.7 Remove a 1734-TOPS Base ....................................................................................................................... 2-7
SECTION 2.5 FIELD WIRING CONNECTIONS ...................................................................................................................... 2-8
2.5.1 Wiring Diagram ........................................................................................................................................ 2-9
2.5.2 System Wiring Configurations ................................................................................................................ 2-10
CHAPTER 3 CONFIGURING THE 1734SC-IF4U-1 USING RSLOGIX 5000 .................................................................. 3-1
SECTION 3.1 INTRODUCTION ........................................................................................................................................ 3-1
SECTION 3.2 ABOUT COMMUNICATIONS......................................................................................................................... 3-1
SECTION 3.3 USE GENERIC PROFILE ............................................................................................................................... 3-2
3.3.1 Add a Local Ethernet Bridge Module ........................................................................................................ 3-3
3.3.2 Add a Remote Ethernet Point IO Adapter ................................................................................................. 3-5
3.3.3 Add the Generic Point IO Module ............................................................................................................. 3-7
SECTION 3.4 USE ADD-ON-PROFILE .............................................................................................................................. 3-8
3.4.1 Installing the Add-On Profile ..................................................................................................................... 3-8
3.4.2 Adding the IF4U-1 Module to Your Logix Project ...................................................................................... 3-9
SECTION 3.5 MODULE CONFIGURATION ....................................................................................................................... 3-10
3.5.1 Channel Configuration Details ................................................................................................................ 3-12
3.5.2 RTD Accuracy .......................................................................................................................................... 3-13
SECTION 3.6 READ INPUT DATA ................................................................................................................................. 3-16
iv Point IO™ 4 Channel Universal Analog Input Module
User’s Manual Pub. 0300316-01 Rev. C
3.6.1 Input Assembly Status Bit Definitions ..................................................................................................... 3-17
APPENDIX A MODULE SPECIFICATIONS ...............................................................................................................A-1
INDEX ................................................................................................................................................................. I-1
Point IO™ 4 Channel Universal Analog Input Module v
User’s Manual Pub. 0300316-01 Rev. C
Preface Read this preface to familiarize yourself with the rest of the manual. This preface
covers the following topics:
Who should use this manual
How to use this manual
Related documentation
Technical support
Documentation
Conventions used in this manual
Who Should
Use This Manual Use this manual if you are responsible for designing, installing, programming, or
troubleshooting control systems that use Allen-Bradley I/O and/or compatible
controllers, such as CompactLogix and ControlLogix.
How to Use
This Manual As much as possible, we organized this manual to explain, in a task-by-task
manner, how to install, configure, program, operate, and troubleshoot a control
system using the 1734sc-IF4U-1.
Related
Documentation The table below provides a listing of publications that contain important
information about Allen-Bradley PLC systems.
For
Refer to this Document
Allen-Bradley
Pub. No.
A description and overview of the
1734 and 1734D series POINT I/O
modules and compatible control
platforms. Also includes an
overview of how to specify a
POINT I/O system.
POINT I/O Selection
Guide
1734-SG001
Information about how to install
the 1734-EP24DC, Series B
POINT I/O 24 VDC Expansion
Power Supply.
Expansion Power
Supply Installation
Instructions
1734-IN058
Information about how to install
1734-TB and -TBS POINT I/O
Wiring Base Assemblies
Wiring Base Assembly
Installation Instructions
1734-IN511
Information about how to install
1734-TB3 and -TB3S POINT I/O
Wiring Base Assemblies.
Wiring Base Assembly
Installation Instructions
1734-IN013
vi Point IO™ 4 Channel Universal Analog Input Module
User’s Manual Pub. 0300316-01 Rev. C
Technical
Support For technical support, please contact your local Rockwell Automation
TechConnect Office for all Spectrum products. Contact numbers are as follows:
USA 440-646-6900
United Kingdom 01908 635230
Australia 1800-809-929
Mexico 001-888-365-8677
Brazil (55) 11 3618 8800
Europe +49 211 41553 63
or send an email to
support@spectrumcontrols.com
Documentation If you would like a manual, you can download a free electronic version from the
Internet at www.spectrumcontrols.com
Conventions
Used in This
Manual The following conventions are used throughout this manual:
Bulleted lists (like this one) provide information not procedural steps.
Lists provide sequential steps or hierarchical information.
Italic type is used for emphasis.
Bold type identifies headings and sub-headings:
WARNING
Identifies information about practices or circumstances that can lead to
personal injury or death, property damage, or economic loss. These
messages help you to identify a hazard, avoid a hazard, and recognize the
consequences.
ATTENTION
Actions ou situations risquant d’entraîner des blessures pouvant être
mortelles, des dégâts matériels ou des pertes financières. Les messages «
Attention » vous aident à identifier un danger, à éviter ce danger et en
discerner les conséquences.
NOTE
Identifies information that is critical for successful application and
understanding of the product.
User’s Manual Pub. 0300316-01 Rev. C
Chapter 1
Module Overview
This chapter describes the 1734sc-IF4U and the conformally coated 1734sc-
IF4KU-1 modules. Other than the conformal coating, both modules are identical
so all information applicable to the 1734sc-IF-1 also applies to the K version.
The 1734sc-IF4U-1 module has four analog input channels that support current,
voltage, RTD, resistance, and thermocouple input types.
NOTE
For applications that require it, the 1734sc-IF4U-1 provides greater RTD
accuracy than the 1734sc-IF4U.
This chapter includes information about:
General description
Input types
Data formats
Filter frequencies
Hardware features
System overview
Module operation
1-2 Chapter 1: Module Overview
User’s Manual Pub. 0300316-01 Rev. C
Section 1.1
General
Description The IF4U-1 module digitally converts and stores analog data for each configured
input. Each input channel can be independently configured for input type, data
format, and filter frequency.
NOTE
All Spectrum Controls 1734sc modules also function normally when
attached to 1769-L1x processors. These processors allow 1734sc modules
to be attached directly to the side and become local IO.
Section 1.2
Input Types The IF4U-1 module supports the following input types.
Table 1-1. Input Types
Input Type
Range
E Type Thermocouple
-270 to 1000 ˚C (-454 to 1832 ˚F)
J Type Thermocouple
-210 to 1200 ˚C (-346 to 2192 ˚F)
K Type Thermocouple
-270 to 1370 ˚C (-454 to 2498 ˚F)
T Type Thermocouple
-270 to 400 ˚C (-270 to 752 ˚F)
100 Ω Pt α 0.385
-200 to 850 ˚C (-328 to 1562 ˚F)
1000 Ω Pt α 0.385
-200 to 850 ˚C (-328 to 1562 ˚F)
100 Ω Pt α 0.3916
-200 to 630 ˚C (-328 to 1166 ˚F)
1000 Ω Pt α 0.3916
-200 to 630 ˚C (-328 to 1166 ˚F)
Resistance
0 to 3000
Voltage
±50 mV
±100 mV
±1 V
0 to 5 V
1 to 5 V
±9 V
0 to 9 V
Current
4 to 20 mA
0 to 20 mA
CJC
-25 to 85 ˚C
Chapter 1: Module Overview 1-3
User’s Manual Pub. 0300316-01 Rev. C
Section 1.3
Data Formats For each channel, the data can be configured for:
Engineering units ×1
Engineering units ×10
Scaled-for-PID
Raw/proportional counts
Section 1.4
Filter
Frequencies The module uses a notch filter to provide noise rejection for each input channel.
The filter for each channel is programmable, allowing you to select from 4
different filter options:
4.17 Hz
16.7 Hz
62 Hz
470 Hz
Section 1.5
Hardware
Features Channels are wired as differential inputs.
Module configuration is done via the controller’s programming software. The
module configuration is stored in the memory of the controller. Refer to your
controller’s user manual for more information. The illustration below shows the
module’s hardware features.
1-4 Chapter 1: Module Overview
User’s Manual Pub. 0300316-01 Rev. C
Figure 1-1. Hardware Diagram
Figure 1-2. Hardware Details
Chapter 1: Module Overview 1-5
User’s Manual Pub. 0300316-01 Rev. C
1.5.1 LED Indicators
The 1734 analog HART module uses several LEDs to show operational status.
The status LEDs are defined below:
Table 1-2. LED Status Indicators
Indicator
Description
Module
Status
No power applied to device.
Device operating normally.
Device needs commissioning due to configuration missing,
incomplete, or incorrect.
NOTE: The module always sets default values for invalid
configurations. Therefore, this status will not be shown.
Not used with this module.
Recoverable fault.
ADC communications fault, or backplane communications error.
Device is in self-test mode.
This is only used during factory test and power-up.
Channel
Status
Channel disabled. Will remain off after power-up until connection
established. Analog processing will not take place if no connection is
made.
Normal (channel scanning inputs).
Calibration mode.
Major channel fault.
ADC communications fault.
Analog values will remain at current state until fault has recovered.
Channel at end of range.
Displayed during power-up.
Network
Status
Device not powered/Not online.
Device operational AND online AND connected.
Device operational AND online but not connected.
OR
Device online AND device needs commissioning.
Minor fault AND/OR connection timeout AND/OR no network
power.
Critical fault OR critical link failure.
1-6 Chapter 1: Module Overview
User’s Manual Pub. 0300316-01 Rev. C
Indicator
Description
Communication faulted and received an identify comm fault request -
long protocol.
Also displayed during power-up.
Section 1.6
System
Overview The module communicates to the controller via a 1734 Control Net, Device Net,
or Ethernet adapter. The module receives 5 and 24 VDC power through the bus
interface.
1.6.1 Module Power-up
At power-up, the module performs a check of its internal circuits, memory, and
basic functions. If no faults are found during power-up diagnostics, the module
status LED is turned on.
After power-up checks are complete, the module waits for valid channel
configuration data. If an invalid configuration is detected, the module will
generate a PLC fault. Once a channel is properly configured and enabled, it
continuously converts the input data to a value within the range selected for that
channel.
1.6.2 Module Operation
The 1734sc-IF4U-1 module provides four, independent, analog input channels.
Each channel includes four selectable filter settings, and can be configured for
voltage, thermocouple, current, resistance, or RTD input types.
The 1734sc-IF4U-1 module uses a 20-bit Sigma-Delta ADC (Analog to Digital
Converter) to achieve 18-bit resolution. (This may be limited to 16-bits resolution
by backplane communication.) Inputs to the ADC are first multiplexed through
analog switches, and then buffered by a precision, low offset and drift,
programmable gain amplifier. The ADC also provides the programmable current
source used in resistive measurements.
The 1734sc-IF4U-1 plug-in module communicates over its isolated CAN Bus
interface through the module backplane. The 1734 network adapter then
communicates to the PLC controller.
Chapter 1: Module Overview 1-7
User’s Manual Pub. 0300316-01 Rev. C
See the block diagram below:
+24VDC +3.3VDC ±2%
-15VDC ±3VDC
GND
Isolated
CAN Bus
CAN
Bus
and
+5VDC
ADC
SPI Interface
Voltage / Current (4-chs)
RTD / Resistance (2/4-chs)
Thermocouple (3-chs)
GND
Analog_1
Analog_0
I
s
o
l
a
t
i
o
n
Point Bus LEDs
Processor
Isolation
Barrier
Controls and Status
Controls
Notes:
1) I/O’s are ESD protected
CJC (1-ch)
Analog_2
Protection,
Filtering,
Analog
Switch
Matrix,
PGA
+15VDC ±3VDC
Current Srcs
PGA_Interrupt
Low
Input-Power
Interrupt
and
System_Reset
SPI Interface
Power Supplies
And
Power Monitor
Isolation
Barrier CLK System
Clock
Generator
1-8 Chapter 1: Module Overview
User’s Manual Pub. 0300316-01 Rev. C
User’s Manual Pub. 0300316-01 Rev. C
Chapter 2
Installation and Wiring
This chapter will cover:
Compliance to European union directives
Power requirements
General considerations
Mounting
Field wiring connections
Section 2.1
Compliance to
European
Union Directives This product is approved for installation within the European Union and EEA
regions. It has been designed and tested to meet the following directives.
2.1.1 EMC Directive
The 1734sc-IF4U-1 module is tested to meet Council Directive 2014/30/EU
Electromagnetic Compatibility (EMC) and the following standards, in whole or
in part, documented in a technical construction file:
EN 61000-6-4 Electromagnetic compatibility (EMC)Part 6-4: Generic
standardsEmission standard for industrial environments.
EN 61000-6-2 Electromagnetic compatibility (EMC)Part 6-2: Generic
standardsImmunity for industrial environments.
UKCA Electromagnetic Compatibility Regulations 2016
BS EN 61131-2, BS EN 61000-6-4, BS EN 61000-6-2.This product is
intended for use in an industrial environment.
2.1.2 ATEX Directive
This product is tested to meet Council Directive 2014/30/U/ATEX, and the
following standards, in whole or in part, documented in a technical construction
file:
EN 60079-0 Explosive atmospheres Part 0: Equipment General
requirements
EN 60079-7 Explosive atmospheres Part 7: Equipment protection by
increased safety "e"
This module also meets the standards for the United Kingdom Equipment and
Protective Systems Intended for use in Potentially Explosive Atmospheres
Regulations 2016:
BS EN 60079-0
BS EN 60079-7
2-2 Chapter 2: Installation and Wiring
User’s Manual Pub. 0300316-01 Rev. C
Section 2.2
Power
Requirements
NOTE
Your 24 V external power supply for the AENT adapter supplies the same
GND used for the analog portion of the IF4U-1. If you measure a voltage
source with its negative terminal also attached to chassis GND, the module
may be susceptible to noise (especially at greater Vin values while only
one channel is attached), IF the external power supply introduces a high
level of noise between its GND and chassis GND.
To remedy this, you may try a different power supply; attach the negative
terminal of the power supply to chassis GND, or simply disconnect chassis
GND from the negative terminal of voltage source being measured.
WARNING
HAZARD OF DAMAGE to the 1734sc-IF4U-1 Module
Do NOT use a 1734-EPAC power supply. This outputs 120 VAC to the
+24 V input of the IF4U-1 module. Use a power supply that matches the
+24 V input.
The module receives power through the bus interface from the +5 VDC/+24
VDC system power supply. The maximum current drawn by the module is
shown in the table below:
24 VDC
20 mA (maximum)
Section 2.3
General
Considerations 1734 I/O is suitable for use in an industrial environment when installed in
accordance with these instructions. Specifically, this equipment is intended for
use in clean, dry environments Pollution degree 2
1
and to circuits not exceeding
Over Voltage Category II
2
(IEC 60664-1)
3
.
2.3.1 Hazardous Location Considerations
This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or
non-hazardous locations only. The following WARNING statement applies to
use in hazardous locations.
1
Pollution Degree 2 is an environment where, normally, only non-conductive pollution occurs except that
occasionally a temporary conductivity caused by condensation shall be expected.
2
Over Voltage Category II is the load level section of the electrical distribution system. At this level transient
voltages are controlled, and do not exceed the impulse voltage capability of the product’s insulation.
3
Pollution Degree 2 and Over Voltage Category II are International Electrotechnical Commission (IEC)
designations.
Chapter 2: Installation and Wiring 2-3
User’s Manual Pub. 0300316-01 Rev. C
WARNING
EXPLOSION HAZARD
Substitution of components may impair suitability for Class I,
Division 2.
Do not replace components or disconnect equipment unless power
has been switched off or the area is known to be non-hazardous.
Touch a grounded object to discharge static potential.
Do not connect or disconnect components unless power has been
switched off or the area is known to be non-hazardous.
This product must be installed in an IP54 rated enclosure.
All wiring must comply with N.E.C. article 501-4(b).
2.3.2 Prevent Electrostatic Discharge
WARNING
Electrostatic discharge can damage integrated circuits or semiconductors if
you touch analog I/O module bus connector pins or the terminal block on
the input module. Follow these guidelines when you handle the module:
Touch a grounded object to discharge static potential.
Wear an approved wrist-strap grounding device.
Do not touch connectors or pins on component boards.
Do not touch circuit components inside the module.
If available, use a static-safe workstation.
When not in use, keep the module in its static-shield box.
2.3.3 Remove Power
WARNING
Remove power before removing or inserting this module. When you
remove, or insert, a module with power applied, an electrical arc may
occur. An electrical arc can cause personal injury or property damage by:
Sending an erroneous signal to your system’s field devices,
causing unintended machine motion.
Causing an explosion in a hazardous environment.
Electric arcing causes excessive wear to contacts on both the
module and its mating connector and may lead to premature
failure.
2.3.4 Selecting a Location
Reducing Noise
Most applications require installation in an industrial enclosure to reduce the
effects of electrical interference. Analog inputs are highly susceptible to
electrical noise. Electrical noise coupled to the analog inputs will reduce the
performance (accuracy) of the module. Group your modules to minimize adverse
effects from radiated electrical noise and heat.
2-4 Chapter 2: Installation and Wiring
User’s Manual Pub. 0300316-01 Rev. C
Consider the following conditions when selecting a location for the analog
module. Position the module:
Away from sources of electrical noise such as hard-contact switches,
relays, and AC motor drives.
Away from modules which generate significant radiated heat. Refer to
the module’s heat dissipation specification.
In addition, route shielded, twisted-pair, analog input wiring away from any high
voltage I/O wiring.
Section 2.4
Mounting
2.4.1 Before You Begin
Note that this series C product can be used with the following:
ControlNet and EtherNet/IP adapters ONLY, using RSLogix 5000
software, version 11 or later.
See the figures to familiarize yourself with major parts of the module, noting that
the wiring base assembly is one of the following:
1734-TB or 1734-TBS POINT I/O two-piece terminal base, which
includes the 1734-RTB removable terminal block and 1734-MB
mounting base.
1734-TOP or 1734-TOPS POINT I/O one-piece terminal base.
Chapter 2: Installation and Wiring 2-5
User’s Manual Pub. 0300316-01 Rev. C
2.4.2 Install Mounting Base
WARNING
During panel or DIN rail mounting of all devices, be sure that all debris
(metal chips, wire strands, etc.) is kept from falling into the module.
Debris that falls into the module could cause damage when power is
applied to the module.
To install the mounting base on the DIN rail, proceed as follows:
1. Position the mounting base vertically above the installed units (adapter,
power supply or existing module).
2. Slide the mounting base down, allowing the interlocking side pieces to
engage the adjacent module or adapter.
3. Press firmly to seat the mounting base on the DIN rail. The mounting
base will snap into place.
4. To remove the mounting base from the DIN rail, remove the module, and
use a small-bladed screwdriver to rotate the base locking screw to a
vertical position. This releases the locking mechanism. Then lift straight
up to remove.
2.4.3 Install the I/O Module
The module can be installed before, or after base installation. Make sure that the
mounting base is correctly keyed before installing the module into the mounting
base. In addition, make sure the mounting base locking screw is positioned
horizontal referenced to the base:
2-6 Chapter 2: Installation and Wiring
User’s Manual Pub. 0300316-01 Rev. C
1. Using a bladed screwdriver, rotate the key switch on the mounting base
clockwise until the number required for the type of module being
installed aligns with the notch in the base.
2. Make certain the DIN rail locking screw is in the horizontal position.
(You cannot insert the module if the locking mechanism is unlocked.)
3. Insert the module straight down into the mounting base and press to
secure. The module will lock into place.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62

Spectrum Controls 140 AUI 040 00sc Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI