APC SUDP001 Datasheet

Category
Uninterruptible power supplies (UPSs)
Type
Datasheet

This manual is also suitable for

APC SUDP001 is a service bypass panel that allows you to safely bypass your UPS during maintenance or service. It is compatible with Smart-UPS DP models and provides the following features:

  • Remote bypass capability: Allows you to bypass the UPS remotely via a network connection.
  • Manual bypass capability: Allows you to bypass the UPS manually using a switch on the front panel.
  • Automatic bypass capability: Automatically bypasses the UPS in the event of a power failure.
  • Load shedding capability: Allows you to shed non-critical loads in the event of a power failure to extend the runtime of critical loads.

APC SUDP001 is a service bypass panel that allows you to safely bypass your UPS during maintenance or service. It is compatible with Smart-UPS DP models and provides the following features:

  • Remote bypass capability: Allows you to bypass the UPS remotely via a network connection.
  • Manual bypass capability: Allows you to bypass the UPS manually using a switch on the front panel.
  • Automatic bypass capability: Automatically bypasses the UPS in the event of a power failure.
  • Load shedding capability: Allows you to shed non-critical loads in the event of a power failure to extend the runtime of critical loads.
1 990-1013, Revision 1, 7/99
Installation Note for Smart-UPS DP Accessories English
Optional accessories for the Smart-UPS DP include an extended run battery cabinet (SUDPBP1/SUDPBP2) and a service
bypass panel (SUDP001/SUDP002). During the installation of either of these options, you must attach a ferrite bead on
the signal cable to ensure regulatory compliance.
Note:
When installing either the extended run battery cabinet or the service bypass panel, you must complete the following
steps to ensure that the Smart-UPS DP passes all regulatory tests. Failure to complete these installation steps may void
regulatory compliance.
How to Install a Ferrite Bead
1. Follow the installation instructions for the accessory until the wiring is complete. (Refer to the Smart-UPS DP User’s
Manual for instructions.) Leave the back cover of the Smart-UPS DP off.
2. Open the ferrite bead by inserting a coin or finger nail under the lip Œ on the side of the ferrite bead and gently lift it
over the ridge . The unit will open in two halves.
3. Squeeze together, twist, or tape the wires connected to the input signal connector (for the particular option) to reduce
the overall diameter.
4. With the ferrite bead open, position the wires in the groove on one side of the ferrite bead.
6)5)
4)
3)
2)
1)
2. REPLACEMENT
1. REPLACEMENT
INSTALLED
YEARMONTH
REPLACEMENT OF BATTERIES
KG.WEIGHT:
S. NO.:
TYPE:
P.NO.:
L
OUTPUT
NNL
INPUT
EXTERNAL BATTERY
BEFORE CONNECTING TO
SEE INSTALLATION INSTRUCTIONS
DANGER
ComPort
Ext. Battery
384V DC
HIGH VOLTAGE
BATT. TEMP. SENSOR
FOR EXTERNAL
TEMP. SENSOR
INTERNAL BATT.
TEMP. SENSOR
FOR BATTERY
TR. TH. SWITCH
FOR EXTERNAL
1 2 3 4
COM. FAULT
1 2 3 4
MBS CONTROL
BLACKRED
BATT. TEMP. SENSOR
FOR EXTERNAL
TEMP. SENSOR
INTERNAL BATT.
TEMP. SENSOR
FOR BATTERY
TR. TH. SWITCH
FOR EXTERNAL
1 2 3 4
COM. FAULT
1 2 3 4
MBS CONTROL
BLACK
RED
Ž Signal connector for the service bypass panel option
Signal connector for the extended run battery cabinet option (shown with ferrite installed)
5. Close the other half of the ferrite bead around the wires until the lip seals (you should hear a “snap” when it closes).
Œ
Ž
990-1013, Revision 1, 7/99 2
6. If the Smart-UPS DP has both options, repeat steps 2 through 5 to install the ferrite bead for the second option. The
following figure shows two ferrite beads installed since the Smart-UPS DP is equipped with both the extended run
battery cabinet and the service bypass panel.
Ž Signal connector for the service bypass panel option
Signal connector for the extended run battery cabinet option (shown with ferrite installed)
7. Replace the rear panel cover on the Smart-UPS DP.
Ž
  • Page 1 1
  • Page 2 2

APC SUDP001 Datasheet

Category
Uninterruptible power supplies (UPSs)
Type
Datasheet
This manual is also suitable for

APC SUDP001 is a service bypass panel that allows you to safely bypass your UPS during maintenance or service. It is compatible with Smart-UPS DP models and provides the following features:

  • Remote bypass capability: Allows you to bypass the UPS remotely via a network connection.
  • Manual bypass capability: Allows you to bypass the UPS manually using a switch on the front panel.
  • Automatic bypass capability: Automatically bypasses the UPS in the event of a power failure.
  • Load shedding capability: Allows you to shed non-critical loads in the event of a power failure to extend the runtime of critical loads.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI