Microlife IR 210 User manual

Category
Digital body thermometers
Type
User manual
IB IR 210 S-V11 2920
Revision Date: 2020-07-28
Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
www.microlife.com
IR
210
Ear Thermometer
Microlife IR 210
3
EN
ES
FR
IT
DE
NL
GR
TR
AR
FA
1
7
15
23
31
47
55
63
69
75
PT 39
2
3a
3b
4 5
1a
1b
Microlife IR 210 IR 210Guarantee Card
AT
AK
AL
AM
AN
AO
AP
AQ
AR
AS
BT
BK
BL
BO
7
8
9
BP
BR
BS
CT
BQ
BM
BN
CK
AT
AK
AL
AM
AN
AO
AP
AQ
AR
AS
BT
BK
BL
BO
7
8
9
BP
BR
BS
CT
BQ
BM
BN
CK
CL
Name of Purchaser / Nombre del comprador/
Nom de l'acheteur / Nome del rivenditore / Name
des Käufers / Nome do comprador / Naam koper
/ Ονοματεπώνυμο αγοραστή / Alıcının adı /
/
Serial Number / Número de serie/ Numéro de
série / Numero di serie / Serien-Nr. / Número
de série / Serienummer / Αριθμός σειράς / Seri
numarası / /
Date of Purchase / Fecha de compra/ Date
d'achat / Data d’acquisto / Kaufdatum / Data
da compra / Datum van aankoop / Ημερομηνία
αγοράς / Satın alma tarihi / /
Specialist Dealer / Distribuidor especializado/
Revendeur / Categoria rivenditore / Fachhändler
/ Revendedor autorizado / Specialist Dealer /
Εξειδικευμένος αντιπρόσωποςa / Uzman satıcı
/
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
FA
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا
BP W100
١٢
AR
ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
(ﻲﻔﻠﺨﻟا ءﺎﻄﻐﻟا ﺮﻈﻧا) ﺔﻟﺎﻔﻜﻟا ﺔﻗﺎﻄﺑ
:يﺮﺘﺸﻤﻟا ﻢﺳا
:ﻞﻳدﻮﻤﻟا
:ﻞﺴﻠﺴﺘﻟا ﻢﻗر
:ءاﺮﺸﻟا ﺦﻳرﺎﺗ
:ﺺﺘﺨﻤﻟا ﺮﺟﺎﺘﻟا



1
Read the instructions carefully before using this device.
Type BF applied part
This Microlife thermometer is a high quality product incorporating
the latest technology and tested in accordance with international
standards. With its unique technology, this device can provide a
stable, heat-interference-free reading with each measurement.
The device performs a self-test every time it is switched on to
always guarantee the specified accuracy of any measurement.
The Microlife Ear Thermometer is intended for the periodic
measurement and monitoring of human body temperature. It is
intended for use on people of all ages.
This thermometer has been clinically tested and proven to be
safe and accurate when used in accordance to the operating
instruction manual.
Please read through these instructions carefully in order for you to
understand all functions and safety information.
Table of Contents
1. The Advantages of this Thermometer
Measurement in 1 second
Correct position indication
Multiple uses (wide range of measurement)
•Probe cover
Probe LED
Accurate and reliable
Gentle and easy to use
Multiple readings recall
Safe and hygienic
Fever alarm
2. Important Safety Instructions
3. How this Thermometer measures Temperature
To avoid an inaccurate measurement
4. Control Displays and Symbols
5. Setting Date, Time and Beeper Functions
6. Changing between Body and Object Mode
7. Directions for Use
Measuring in body mode
Measuring in object mode
8. Changing between Celsius and Fahrenheit
9. How to recall 30 readings in Memory Mode
10. Error Messages
11. Cleaning and Disinfecting
Microlife Ear Thermometer IR 210
EN
1
Measuring sensor
2
Display
3
M-button (memory)
4
MODE button
5
Battery compartment cover
6
START/IO button
7
All segments displayed
8
Memory
9
Ready for measuring
AT
Correct position indication
AK
Measurement complete
AL
Body mode
AM
Object mode
AN
Incorrect location indication
AO
Error function display
AP
Low battery indicator
AQ
Changing between Celsius and Fahrenheit
AR
Recall mode
AS
Recall the last 30 readings
BT
Measured temperature too high
BK
Measured temperature too low
BL
Ambient temperature too high
BM
Ambient temperature too low
BN
Remove and replace the probe cover
BO
Blank display
BP
Flat battery
BQ
Date/Time
BR
Beeper function setting
BS
Replacing the battery
CT
Storage holder
CK
Probe cover
CL
How to reload a new probe cover
2IR 210
EN
12. Battery Replacement
13. Guarantee
14. Technical Specifications
15. www.microlife.com
Guarantee Card (see Back Cover)
1. The Advantages of this Thermometer
Measurement in 1 second
The innovative infrared technology allows measurement of ear
temperature in only 1 second.
Correct position indication
ACCUsens guidance system confirms the right position in the ear
with «good» displayed on the LCD display and a beep.
Multiple uses (wide range of measurement)
This thermometer offers a wide range of measurement from 0.1-
99.9 °C / 32.2-211.8 °F, meaning the unit can be used to measure
body temperature or it also has a feature allowing it to be used to
measure surface temperature of the following examples:
Milk surface temperature in a baby's bottle
Surface temperature of a baby's bath
Ambient temperature
Probe cover
This thermometer is user-friendly and more hygienic with the
usage of a probe cover.
Probe LED
This thermometer includes a probe LED light which enables the
user to find the correct ear position in the dark.
Accurate and reliable
The unique probe assembly construction incorporates an
advanced infrared sensor, ensuring that each measurement is
accurate and reliable.
Gentle and easy to use
The ergonomic design enables simple and easy use of the ther-
mometer.
This thermometer can even be used on a sleeping child without
causing any interruption.
This thermometer is quick, therefore child-friendly.
Multiple readings recall
Users will be able to recall the last
30
readings with a record of both
time and date when entering the recall mode, enabling efficient
tracking of temperature variations.
Safe and hygienic
No risk of broken glass or mercury ingestion.
Completely safe for use on children.
Using a new probe cover each time, ensures this thermometer
is completely hygienic for use by the whole family.
Fever alarm
10 short beeps and a red LCD backlight alert the patient that he/
she may have a temperature equal to or higher than 37.5 °C.
2. Important Safety Instructions
Follow instructions for use. This document provides important
product operation and safety information regarding this device.
Please read this document thoroughly before using the device
and keep for future reference.
This device may only be used for the purposes described in
these instructions. The manufacturer cannot be held liable for
damage caused by incorrect application.
Never immerse this device in water or other liquids. For
cleaning please follow the instructions in the «Cleaning
and Disinfecting» section.
Do not use this device if you think it is damaged or notice
anything unusual.
Never open this device.
Earwax in the ear canal may cause a lower temperature reading.
Therefore it is important to ensure the subject's ear canal is clean.
Only use this thermometer with a new Microlife branded and
undamaged probe cover to prevent cross-infection.
If the measurement result is not consistent with the patient's
finding or unusually low, repeat the measurement every 15
minutes or double check the result by another core body
temperature measurement.
This device comprises sensitive components and must be
treated with caution. Observe the storage and operating condi-
tions described in the «Technical Specifications» section.
Ensure that children do not use this device unsupervised; some
parts are small enough to be swallowed.
3
Do not use this device close to strong electromagnetic fields such
as mobile telephones or radio installations. Keep a minimum
distance of 3.3 m from such devices when using this device.
Protect it from:
- extreme temperatures
- impact and dropping
- contamination and dust
- direct sunlight
- heat and cold
If the device is not going to be used for a prolonged period the
battery should be removed.
WARNING: The measurement results given by this device
is not a diagnosis. It is not replacing the need for the consul-
tation of a physician, especially if not matching the patient’s
symptoms. Do not rely on the measurement result only,
always consider other potentially occurring symptoms and
the patient’s feedback. Calling a doctor or an ambulance is
advised if needed.
3. How this Thermometer measures Temperature
This thermometer measures infrared energy radiated from the
eardrum and the surrounding tissue. This energy is collected
through the lens and converted to a temperature value. The
measured reading obtained directly from the eardrum (Tympanic
Membrane) ensures the most accurate ear temperature.
Measurements taken from the surrounding tissue of the ear canal
generate lower readings and may result in misdiagnosis of fever.
To avoid an inaccurate measurement
1. Fit a new Microlife branded and undamaged probe cover CK on
the measuring sensor 1.
2. Switch on the thermometer by pressing the START/IO button
6
.
3. After one beep is heard (and the temperature scale icon is
flashing), straighten the ear canal by gently pulling the middle
of the ear back and up.
4. Place the probe 1 firmly into the ear canal. «Good» will be
displayed with a short beep to confirm the device has detected
the correct position. Press the START/IO button 6 and keep
the probe in the ear until the thermometer beeps to signal the
completion of the measurement.
4. Control Displays and Symbols
All segments displayed 7: Press the START/IO button 6 to
turn on the unit; all segments will be shown for 1 second.
Ready for measurement 9: When the unit is ready for
measurement, the «°C» or «°F» icon will keep flashing.
The probe LED light is activated and will keep flashing.
Correct position indication
AT
:
The probe LED light will stop
flashing (stays illuminated) and «good» will be displayed on the
LCD, when the measuring sensor detects an appropriate position.
Measurement complete
AK
:
The reading will be shown on the
display
2
with the «
°C
» or «
°F
» icon; the unit is ready for the
next measurement, when the «
°C
» or «
°F
» icon is flashing again.
Low battery indicator AP: When the unit is turned on, the
«battery» icon will keep flashing to remind the user to replace
the battery.
5. Setting Date, Time and Beeper Functions
Setting the date and time
1. After the new battery is fitted, the year number flashes in the
display BQ. You can set the year by pressing the M-button 3.
To confirm and then set the month, press the MODE button 4.
2. Press the M-button 3 to set the month. Press the MODE
button 4 to confirm and then set the day.
3. Follow the previously mentioned instructions to set the day,
hours and minutes.
4. Once you have set the minutes and pressed the START/IO
button 6, the date and time are set and the time is displayed.
If no button is pressed for 20 seconds, the device automat-
ically switches to ready for measuring 9.
Cancel time setup:
Press the START/IO button
6
during
time setup. The LCD will show Date/Time icons with «--:--».
After that press the START/IO button
6
to start the measure-
ment. If no further action is taken within 60 seconds, the
device will automatically turn off.
Change current date and time:
Press and hold the MODE
button
4
for approx. 8 seconds until the year number starts
to flash
BQ
. Now you can enter the new values as described
above.
Setting the beeper
1. Press and hold the MODE button 4 for 3 seconds to set the
beeper BR.
4IR 210
EN
2. Press the M-button
3
to either turn the beeper on or off. The beeper
is activated when the beeper icon
BR
is shown without a cross.
When the beeper setting has been chosen, press the
START/IO button 6 to enter the «ready for measuring»
mode; otherwise the device automatically switches to ready
for measuring after 10 seconds 9.
6. Changing between Body and Object Mode
1. Press the START/IO button 6. The display 2 is activated to
show all segments for 1 second.
2. The default mode is body mode AL. Press the MODE button 4
to switch to object mode AM. For switching back to body mode,
press the MODE button again.
7. Directions for Use
Measuring in body mode
Important:
Before each measurement, fit a new undamaged probe
cover
CK
on the measuring sensor
1
. Failure to do so will result in
incorrect temperature measurements. How to correctly fit a new
probe cover
CL
is pictured at the beginning of this instruction.
1. Press the START/IO button 6. The display 2 is activated to
show all segments for 1 second.
2. When the «°C» or «°F» icon is flashing, a beep sound is heard
and the thermometer is ready for measuring 9.
3. The probe LED light is activated and will keep flashing.
4. Straighten the ear canal by pulling the ear up and back to give
a clear view of the eardrum.
For children under 1 year; pull the ear straight back.
For children of 1 year to adult; pull the ear up and back.
Also refer to the short instructions at the front.
5. While gently pulling the ear, insert the probe snugly into the ear
canal.
6. The probe LED light will stop flashing (stays illuminated) and
«good» will be displayed on the LCD, when the measuring
sensor detects an appropriate position.
7.
Immediately
press the START/IO button
6
. Release the button
and wait for the beep sound. This indicates the end of the
measurement.
8. Remove the thermometer from the ear canal. The display shows
the measured temperature
AK
.
9. Replace the probe cover
CK
before starting a new measurement.
10.For the next measurement wait until the «°C»/«°F» icon is
flashing and follow steps 5-7 above.
11.Press and hold the START/IO button 6 for 3 seconds to turn
off the device; otherwise the device will automatically switch off
after approx. 60 seconds.
Measuring in object mode
Important: Remove the probe cover before each measurement in
object mode. Failure to do so will result in incorrect temperature
measurements.
1. Press the START/IO button 6. The display 2 is activated to
show all segments for 1 second.
2. Press the MODE button 4 to switch to object mode.
3. Aim the thermometer at the center of the object you want to
measure with a distance of no more than 5 cm. Press the
START/IO button 6. After 1 second a long beep will verify the
completion of measurement.
4. Read the recorded temperature from the LCD display.
5. For the next measurement wait until the «°C»/«°F» icon is
flashing and follow steps 3-4 above.
NOTE:
Patients and thermometer should stay in similar room
condition for at least 30 minutes.
To ensure accurate readings, wait at least 30 sec. after 3-5
continuous measurements.
It is essential that a new undamaged probe cover CK is
used for each measurement. Therefore, this device reminds
the user to take off the used probe cover when turning off the
device. The «probe cover» icon BN is displayed and the probe
LED light will flash for 3 seconds. For cleaning, follow the
instructions in the «Cleaning and Disinfecting» section.
After cleaning the measuring sensor
1
with alcohol, wait 5
minutes before taking the next measurement
, in order to allow
the thermometer to reach its operating reference temperature.
10 short beeps and a red LCD backlight alert the patient that he/
she may have a temperature equal to or higher than 37.5 °C.
For an infant, it is best to have the child lying flat with his/her head
sideways so the ear is facing upwards. For an older child or adult,
it is best to stand behind and slightly to the side of the patient.
Always take the temperature in the same ear, since the temper-
ature readings may be different from ear to ear.
5
In the following situations it is recommended that three temper-
atures in the same ear be taken and the highest one taken as
the reading:
1. New born infants in the first 100 days.
2. Children under three years of age with a compromised
immune system and for whom the presence or absence of
fever is critical.
3. When the user is learning how to use the thermometer for
the first time until he/she has familiarized himself/herself with
the device and obtains consistent readings.
4. If the measurement is surprisingly low.
Don't take a measurement while or immediately after nursing a
baby.
Don't use the thermometer in high humidity environments.
Patients should not drink, eat or exercise before/while taking
the measurement.
Doctors recommend rectal measurement for newborn infants
within the first 6 months, as all other measuring methods might
lead to ambiguous results.
Readings from different measuring sites should not be
compared as the normal body temperature varies by
measuring site and time of day, being highest in the evening
and lowest about one hour before waking up.
Normal body temperature ranges:
- Axillar: 34.7 - 37.3 °C / 94.5 - 99.1 °F
- Oral: 35.5 - 37.5 °C / 95.9 - 99.5 °F
- Rectal: 36.6 - 38.0 °C / 97.9 - 100.4 °F
- Microlife IR 210: 35.4 - 37.4 °C / 95.7 - 99.3 °F
8. Changing between Celsius and Fahrenheit
This thermometer can display temperature readings in either Fahr-
enheit or Celsius. To switch the display between °C and °F, press
and hold the MODE button 4 for 3 seconds; the beeper icon is
shown on the display. Press the MODE button again; the current
measurement scale («°C» or «°F» icon) will be shown on the
display AQ. Change the measurement scale between °C and °F by
pressing the M-button 3. When the measurement scale has been
chosen, press the START/IO button 6 to enter the «ready for
measuring» mode; otherwise the device automatically switches to
ready for measuring after 10 seconds 9.
9. How to recall 30 readings in Memory Mode
This thermometer can recall the last 30 readings with a record of
both time and date.
Recall mode AR: Press the M-button 3 to enter recall mode
when the power is off. The memory icon «M» will flash.
Reading 1 - the last reading AS: Press and release the M-
button 3 to recall the last reading. Number «1» and a flashing
«M» are displayed.
Pressing and releasing the M-button
3
after the last 30 readings
have been recalled will resume the above sequence from reading 1.
10.Error Messages
Measured temperature too high BT: Displays «H» when
measured temperature is higher than 43 °C / 109.4 °F in body
mode or 99.9 °C / 211.8 °F in object mode.
Measured temperature too low BK: Displays «L» when
measured temperature is lower than 32 °C / 89.6 °F in body
mode or 0,1 °C / 32,2 °F in object mode.
Ambient temperature too high BL: Displays «AH» when
ambient temperature is higher than 40.0 °C / 104.0 °F.
Ambient temperature too low BM: Display «AL» when
ambient temperature is lower than 10.0 °C / 50.0 °F.
Incorrect location indication AN: The probe is not correctly
inserted in the ear canal. Please insert the probe as described
in this manual.
Error function display AO: The system has a malfunction.
Blank display BO: Check if the battery has been loaded
correctly. Also check polarity (<+> and <->) of the battery.
Flat battery indication BP: If only the «battery» icon is shown
on the display, the battery should be replaced immediately.
11.Cleaning and Disinfecting
Use an alcohol swab or cotton tissue moistened with alcohol (70%
Isopropyl) to clean the thermometer casing and the measuring
sensor. Ensure that no liquid enters the interior of the device. Never
use abrasive cleaning agents, thinners or benzene for cleaning and
never immerse the device in water or other cleaning liquids. Take
care not to scratch the surface of the sensor lens and the display.
12.Battery Replacement
This device is supplied with one lithium battery, type CR2032. The
battery needs replacing when only the «battery» icon BP is shown
on the display.
Remove the battery cover BS by sliding it in the direction shown.
Insert the new battery with the + at the top.
6IR 210
EN
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
13.Guarantee
This device is covered by a 5 year guarantee from the date of
purchase. During this guarantee period, at our discretion, Microlife
will repair or replace the defective product free of charge.
Opening or altering the device invalidates the guarantee.
The following items are excluded from the guarantee:
Transport costs and risks of transport.
Damage caused by incorrect application or non-compliance
with the instructions for use.
Damage caused by leaking batteries.
Damage caused by accident or misuse.
Packaging/storage material and instructions for use.
Regular checks and maintenance (calibration).
Accessories and wearing parts: Battery.
Should guarantee service be required, please contact the dealer
from where the product was purchased, or your local Microlife
service. You may contact your local Microlife service through our
website:
www.microlife.com/support
Compensation is limited to the value of the product. The guarantee
will be granted if the complete product is returned with the original
invoice. Repair or replacement within guarantee does not prolong
or renew the guarantee period. The legal claims and rights of
consumers are not limited by this guarantee.
14.Technical Specifications
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
According to the Medical Product User Act a biennial technical
inspection is recommended for professional users. Please
observe the applicable disposal regulations.
15.www.microlife.com
Detailed user information about our thermometers and blood pressure
monitors as well as services can be found at
www.microlife.com
.
Type: Ear Thermometer IR 210
Measurement
range:
Body mode: 32.0-43.0 °C / 89.6-109.4°F
Object mode: 0.1-99.9 °C / 32.2-211.8 °F
Resolution: 0.1 °C / °F
Measurement
accuracy
(Laboratory):
Body mode:
±0.2 °C, 35.0 42.0 °C / ±0.4 °F, 95.0 107.6 °F
±0.3 °C, 32.0 34.9 °C and 42.1 43.0 °C /
±0.5 °F, 89.6 94.8 °F and 107.8 109.4 °F
Object mode:
±1.0 °C, 0.1 ~ 99.9 °C / ±2 °F, 32.2 ~ 211.8 °F
Display: Liquid Crystal Display, 4 digits plus special icons
Acoustic:
The unit is turned ON and ready for the measure-
ment: 1 short beep.
Complete the measurement: 1 long beep.
System error or malfunction: 3 short beeps.
Fever alarm: 10 short beeps.
Memory: 30 readings recall in the memory mode with a
record of both time and date.
Backlight:
The display light will be GREEN for 1 second,
when the unit is turned ON.
The display light will be GREEN for 5 seconds,
when a measurement is completed with a reading
less than 37.5 °C / 99.5 °F.
The display light will be RED for 5 seconds, when
a measurement is completed with a reading equal
to or higher than 37.5 °C / 99.5 °F.
Operating
conditions:
10 - 40 °C / 50.0 - 104 °F
15 - 95 % relative maximum humidity
Storage
conditions:
-25 - +55 °C / -13 - +131 °F
15 - 95 % relative maximum humidity
Automatic
Switch-off:
Approx. 1 minute after last measurement has been
taken.
Battery: 1 x CR2032 battery 3V
Battery
lifetime: approx. 800 measurements (using a new battery)
Dimensions: 159 x 43 x 60 mm
Weight: 60 g (with battery), 58 g (w/o battery)
IP Class:
IP22
Reference to
standards:
EN 12470-5; ASTM E1965;
IEC 60601-1; IEC 60601-1-2 (EMC)
; IEC 60601-1-11
Expected
service life: 5 years or 12000 measurements
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81

Microlife IR 210 User manual

Category
Digital body thermometers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI