Product Manual for Dionex IonPac CS19 Columns
TABLE OF CONTENTS
SECTION 1 – INTRODUCTION............................................................................................................ 5
SECTION 2 – ION CHROMATOGRAPHY SYSTEMS...................................................................... 8
SECTION 3 – INSTALLATION ............................................................................................................. 9
3.1. Column Start-Up ........................................................................................................................................................ 9
3.2. Column Storage .......................................................................................................................................................... 9
3.3. System Requirements ................................................................................................................................................. 9
3.3.1. System Requirements for 0.4 mm Operation ..................................................................................................... 9
3.3.2. System Requirements for 2 mm Operation ........................................................................................................ 9
3.3.3. System Requirements for 4 mm Operation ........................................................................................................ 9
3.3.4. System Void Volume....................................................................................................................................... 10
3.4. Installing the Dionex CR-CTC Trap Column for Use with Dionex EGC MSA Cartridge....................................... 11
3.5. Installing the Dionex CTC-1 Cation Trap Column for Eluent Step Change or Gradient Operation ........................ 11
3.6. The Injection Loop ................................................................................................................................................... 11
3.6.1. The 0.4 mm System Injection Loop, 0.4 μL Internal Loop ............................................................................. 11
3.6.2. The 2 mm System Injection Loop, 2 - 15 µL .................................................................................................. 11
3.6.3. The 4 mm System Injection Loop, 10 - 50 µL ................................................................................................ 12
3.7. Sample Concentration .............................................................................................................................................. 12
3.8. Dionex IonPac CG19 Guard/Capillary Guard Column ............................................................................................ 13
3.9. Eluent Storage .......................................................................................................................................................... 13
3.10. Dionex Cation Electrolytically Regenerated Suppressor and
Dionex Cation Capillary Electrolytic Suppressor Requirements ............................................................................. 13
3.11. Dionex Cation MicroMembrane Suppressor Requirements ..................................................................................... 14
3.12. Using Displacement Chemical Regeneration (DCR) with the Chemical Suppression Mode .................................. 14
3.13. Using Dionex AutoRegen™ with the Chemical Suppression Mode ......................................................................... 14
3.14. Detector Requirements ............................................................................................................................................. 15
3.15. Installation of the Capillary Column ........................................................................................................................ 15
SECTION 4 – OPERATION ................................................................................................................. 19
4.1. General Operating Conditions .................................................................................................................................. 19
4.2. Dionex IonPac CS19 Column Operation Precautions .............................................................................................. 19
4.3. Chemical Purity Requirements ................................................................................................................................. 20
4.3.1. Deionized Water .............................................................................................................................................. 20
4.3.2. Inorganic Chemicals ........................................................................................................................................ 20
4.3.3. Solvents ........................................................................................................................................................... 20
4.4. Preparation of Eluent Stock Solution Concentrates ................................................................................................. 21
4.4.1. 1.0 N Methanesulfonic Acid (MSA) Stock Solution ....................................................................................... 21
4.4.2. 0.4 N Dionex Methanesulfonic Acid (MSA) Eluent Concentrate ................................................................... 21
4.4.3. 1.0 N Sulfuric Acid Stock Solution ................................................................................................................. 22
4.4.4. Eluent Preparation ........................................................................................................................................... 22
4.5. Making and Using Eluents that Contain Solvents .................................................................................................... 23