ELK 45 User manual

Category
Fire protection
Type
User manual

This manual is also suitable for

PO Box 100 • Hildebran, NC 28637 • 800-797-9355 • 828-397-4200
Fax 828-397-4415 • www.elkproducts.com • info@elkproducts.com
Self-Contained Electronic Siren
ELK-45
Features
Specifications
The ELK-45 is a loud self-contained electronic
siren in a compact and attractive housing. This
siren draws less current than many competitive
units and features the ability to produce two
distinct sounds from a single input trigger. The
ComboTrigger
option allows controls which have
a single alarm output and pulsing option to activate
both the burglar and fire alarm sounds. The
MilliMiser
option allows the already low current
draw of the ELK-45 to be reduced even lower. This
is ideal for controls with limited alarm output
power. The ELK-45’s removable “U” shaped
mounting bracket makes installation quick and
simple. It’s small and compact size allows it to be
placed in vents, attic eaves and soffits, and other
unique locations where large and bulky units will
not fit. Also available is the ELK-150RT which is
the self-contained siren in a stainless steel
enclosure.
Installer Friendly - Compact & Easy To Mount.
Exterior / Interior use.
MilliMiser
Lowers Current Draw.
ComboTrigger
For Single Outputs.
Pre-Wired For Easy Installation.
Removable “U” Shaped Mounting Bracket.
Lifetime Limited Warranty.
Operating Voltage: 6 to 14 Volts D.C.
Current Draw: 1.2 Amps, (700 mA on MilliMiser
).
Sound Level: 118 dB @ 1 meter, 14 Volts D.C.
Size: 4" x 4" x 3.5", Depth 4".
ELK
PRODUCTS, INC.
Features or Specifications subject to change without notice.
05/02
Instructions
ELK-45
1. Mount the U shaped bracket to the wall.
2. Insert one of the two short bolts into each side of the U shaped bracket with the threads protruding
out.
3. Align the heads of the bolts with the slotted openings on each side of the siren housing.
4. Slide the siren onto the bolt heads. Install a washer and nut on each bolt and tighten.
5. Connect Black wire to Neg (-) of alarm output.
6. Connect Red wire to Pos (+) of alarm output.
NOTE: Siren is factory set for maximum loudness with a current draw of about 1.2 Amps. To lower
the current draw and volume, remove the four screws and cover from the back. Follow the Red
speaker wire to where it solders to the circuit board. Cut this Red wire approx. 3" back from the
board. Splice the Red wire from the speaker to the unused Yellow wire on the circuit board using the
enclosed wire nut.
The ELK-45 is designed for Single Output Alarm Controls that use a STEADY Output for BURG or a
PULSING Output for FIRE. For an Alarm Control panel that has separate BURG and FIRE alarm
outputs connect the Red wire to each output, then program one output for Steady(Burg) and the other
for Pulsing(Fire). Connect the Black wire to Neg.
  • Page 1 1
  • Page 2 2

ELK 45 User manual

Category
Fire protection
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI