3We reserve the right to make technical changes | 83055300eUK – Translation of the original instruction manual (2.0) | ait-deutschland GmbH
Contents
MAKING SETTINGS
............................................................................................... 19
Determine data access.............................................................................. 19
Calling up preset program ..................................................................... 20
Determining temperatures ....................................................................20
Determining priorities ..............................................................................22
Determining system setting .................................................................. 22
Ventilating the system .............................................................................. 26
Fix startup parameters ............................................................................. 27
Save error memory externally ..............................................................27
RBE – room control unit ........................................................................... 27
Pump ow ........................................................................................................ 27
Smart ................................................................................................................... 28
Smart Grid ........................................................................................................ 28
Operating states ........................................................................................ 28
Set decrease / increase ..........................................................................29
Terminal diagram Smart Grid .............................................................29
SELECTING LANGUAGE OF THE SCREEN DISPLAY
.....................................29
DETERMINING DATE AND TIME
....................................................................... 29
SCREED HEATING PROGRAM
............................................................................ 30
Setting temperatures and time intervals .......................................30
Starting screed heating program ....................................................... 31
Manually terminating screed heating program ......................... 31
HEATPUMP CONFIGURATION
........................................................................... 32
STARTUP GUIDE
.................................................................................................... 32
RESET STARTUP PARAMETERS
......................................................................... 32
DATA LOGGER
........................................................................................................ 32
CONTROL PANEL
................................................................................................... 32
Adjusting the contrast of the control unit display .................... 32
Web server ....................................................................................................... 32
Remote maintenance ................................................................................ 32
APPENDIX
ERROR DIAGNOSIS / ERROR MESSAGES ..................................................34
Acknowledging a fault .................................................................................38
Flashing codes on controller board......................................................38
TECHNICAL DATA .................................................................................................. 38
Installation .......................................................................................................... 38
Outputs ................................................................................................................ 38
Inputs .....................................................................................................................38
Connections .......................................................................................................38
Interfaces ............................................................................................................. 38
Protection class ................................................................................................38
Temperature sensor characteristic curve .......................................... 39
Sensor measuring range .............................................................................39
OVERVIEW: DEFROST CYCLE, AIR DEFROST, FLOW MAX .............40
SYSTEM SETTING DURING COMMISSIONING ...................................... 41
ABBREVIATIONS SELECTION .......................................................................44
PLEASE READ FIRST.................................................................................................2
SYMBOLS .......................................................................................................................2
SCOPE OF DELIVERY, MONTAGE, ELECTRICAL CONNECTIONS,
INSTALLATION OF SENSORS, DISMANTLING
SCOPE OF DELIVERY ...............................................................................................4
Installed control scope of supply ..............................................................4
Wall control scope of supply .......................................................................4
MONTAGE ......................................................................................................................4
Assembly of the installed control .............................................................4
Assembly of the wall control .......................................................................4
ELECTRICAL CONNECTIONS ..............................................................................5
Motherboard ........................................................................................................5
Installation of the Wall control ...................................................................6
Control unit variants ........................................................................................7
Assembly and Installation of sensors .....................................................8
External sensor .................................................................................................8
Hot water sensor .............................................................................................8
External return ow sensor .......................................................................9
DISMANTLING ............................................................................................................9
Removal of the buer battery ....................................................................9
SOFTWAREUPDATE / DOWNGRADE ...........................................................9
SWITCHING ON / COMMISSIONING ........................................................... 10
STARTUP GUIDE ......................................................................................................11
Fix startup parameters................................................................................. 12
Reset startup parameters ........................................................................... 12
PROGRAM AREA “COOLING“
SELECT PROGRAM AREA
.................................................................................... 13
SETTING THE MODE OF OPERATION “COOLING“
...................................... 13
SET TEMPERATURES
............................................................................................. 14
SET PARAMETERS
................................................................................................. 14
PROGRAM AREA “SERVICE“
SEKECT PROGRAM AREA
.................................................................................... 15
QUERY INFORMATION
......................................................................................... 15
Query temperatures ................................................................................... 15
Query inputs ................................................................................................... 16
Query outputs ............................................................................................... 16
Query elapsed times ...................................................................................17
Query operating hours ..............................................................................17
Query error memory ...................................................................................17
Query outages ................................................................................................17
Query the facility status ........................................................................... 18
Heat quantity ................................................................................................. 18
Query building services management system (BMS) ............. 18
Query Smart .................................................................................................... 19