  • Hello! I am an AI chatbot trained to assist you with the BRAVILOR BONAMAT B10 HW Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B HW-Serie (HW section)
(01-2019 / A)
1 / 5
9.
L
8.
G
7.
K M NL
6.
M
5.
M
4.
K M NL
3.
2.
1.
The descaling symbol ashes.
An audible signal sounds and the level
blocks ash.
Press key ‘L to conrm.Press key ‘G’ to start the descaling program.
Press key ‘M’.Press key ‘M’.Press key ‘M’.
PIN code: Press 1x K,
3x N(↑↑↑),
1x M (↓) and
1x N (↑).
Dissolve 100 grams of Renegite in 1 litre of
hand-warm water (approx. 40 °C).
Stir the descaling solution, so that the agent
is solved well.
Read the safety instructions.
Descaling procedure B HW-serie (Hot water system)
MAN Descale B HW-Serie (HW section).indd 1 16-1-2019 14:20:09
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B HW-Serie (HW section)
(01-2019 / A)
2 / 5
18.
80º C
17.
L
16.
15.14.13.
L
12.
ca. 1 cm
11.
10.
Pour hot water into the hot water boiler to
just above the lime edge (this speeds up the
descaling process).
The hot water boiler is lled with water and
warmed up. This takes some time.
If the Renegite solution has been added,
press key ‘L’.
Place the funnel in the lling opening.
Carefully pour the Renegite solution through
the funnel.
Remove the plug from the lling opening for
the Renegite solution.
The machine is ready to add descaling
solution.
The hot water boiler is empty.
Press key ‘L’. (Close the tap!)
Pull the overow pipe up by the short hose
to fully drain the boiler.
(Tap open!).
Empty the hot water boiler through the tap.
MAN Descale B HW-Serie (HW section).indd 2 16-1-2019 14:20:11
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B HW-Serie (HW section)
(01-2019 / A)
3 / 5
27.26.25.
24.
80º C
L
23.
ca. 1 cm
22.
21.20.19.
Empty the hot water boiler through the tap.
The hot water boiler is full.
The hot water boiler is lled with water and
warmed up. This takes some time.
Pour hot water into the hot water boiler to
just above the lime edge (this speeds up the
descaling process).
The hot water boiler is empty.
Press key ‘L’. (Close the tap!)
Pull the overow pipe up by the short hose
to fully drain the boiler.
(Tap open!).
Empty the hot water boiler through the tap.
The hot water boiler is full.
Wait for 5 minutes for the Renegite to work.
MAN Descale B HW-Serie (HW section).indd 3 16-1-2019 14:20:12
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B HW-Serie (HW section)
(01-2019 / A)
4 / 5
36.
80º C
L
35.
ca. 1 cm
34.
33.32.31.
30.
80º C
L
29.
ca. 1 cm
28.
Pour hot water into the hot water boiler to
just above the lime edge (this speeds up the
descaling process).
The hot water boiler is empty.
Press key ‘L’. (Close the tap!)
Pull the overow pipe up by the short hose
to fully drain the boiler.
(Tap open!).
Empty the hot water boiler through the tap.
The hot water boiler is full.
The hot water boiler is lled with water and
warmed up. This takes some time.
Pour hot water into the hot water boiler to
just above the lime edge (this speeds up the
descaling process).
The hot water boiler is empty.
Press key ‘L’. (Close the tap!)
Pull the overow pipe up by the short hose
to fully drain the boiler.
(Tap open!).
MAN Descale B HW-Serie (HW section).indd 4 16-1-2019 14:20:13
Original document by manufacturer
© Copyright Bravilor Bonamat B.V.
MAN Descale B HW-Serie (HW section)
(01-2019 / A)
5 / 5
44.43.
42.
L
41.
ca. 1 cm
40.
39.38.37.
Note:
Reference model B5 L/R
The descaling program has been closed.
The display shows the user menu.
The counter reading is automatically reset
to zero.
The display shows the counter reading.
The hot water boiler is empty.
Press key ‘L’. (Close the tap!)
Pull the overow pipe up by the short hose
to fully drain the boiler.
(Tap open!).
Empty the hot water boiler through the tap.
The hot water boiler is full.
The hot water boiler is lled with water and
warmed up. This takes some time.
MAN Descale B HW-Serie (HW section).indd 5 16-1-2019 14:20:14
/