1. Meaning of symbols
Caution!
Danger of personal injury!
The following safety advice must
be observed at all times so as to avoid
personal injury!
Attention!
Danger of material damage!
The following safety advice must
be observed at all times so as to avoid
material damage!
Advice / Tip
Check
Reference
i
Photocell or closing edge safety device (CESD)
Gate position OPEN
Has no function
Gate position CLOSED
Reference control point
Has no function
Impulse
(remote control, external control elements)
Operation
Closing edge safety device
STOP
External control elements
Modular antenna
Controls and motor unit symbols Advice
Type plate on motor unit 2 (only double wing)
Type: ________________________________________________
Art. No.: _____________________________________________
Product No.: __________________________________________
Type plate on motor unit 1
Type: ________________________________________________
Art. No.: _____________________________________________
Product No.: __________________________________________
Type plate on control unit
Type: ________________________________________________
Art. No.: _____________________________________________
Product No.: __________________________________________
2 Manual for installation and operation, Comfort 520 accu GB (#89133)
2. Table of contents
1. Meaning of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2. Table of contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3. General safety advice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4. Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4.1 Comfort 520 accu supply package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
4.3 Gate variations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5. Preparation for mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.1 General notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.2 Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
5.3 Cabling layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
6. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6.1 Mounting conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
6.2 Installing the motor unit at the gate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
6.3 Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
6.4 Fixing the control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
6.5 Connection of control elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
6.6 Connecting the motor unit to the controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
6.7 Cabling for the operator system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
7. Hand transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
7.1 Operation and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
7.2 Hand transmitter coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
8. Initial operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
8.1 Connecting the modular antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
8.2 Overview of the control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
8.3 Overview of the display functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
8.4 Reference point . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
8.5 Express programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
8.6 Function test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
9. Extended operator functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
9.1 General notes on extended operator functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
9.2 Programming structure for extended operator functions (Example for Level 2, Menu 2) . . . . . . . . . . . . .38
9.3 General overview of the programmable functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
9.4 Functions overview for the levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
10. Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
10.1 Status messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
10.2 Fault messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
10.3 Rectifying faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
11. Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
11.1 Connection diagram Comfort 520 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
11.2 Technical Data for Comfort 520 accu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
11.3 Manufacturer’s Declaration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
11.4 EC Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Manual for installation and operation, Comfort 520 accu GB (#89133) 3
Please read carefully!
Target group
This operator system may only be installed, connected and put into operation by qualified and trained professionals!
Qualified and trained specialist personnel are persons
- who have knowledge of the general and special safety regulations,
- who have knowledge of the relevant electro-technical regulations,
- with training in the use and maintenance of suitable safety equipment,
- who are sufficiently trained and supervised by qualified electricians,
- who are able to recognise the particular hazards involved when working with electricity,
- with knowledge regarding applications of the EN 12635 standard (installation and usage requirements).
Warranty
For an operations and safety warranty, the advice in this instruction manual has to be observed. Disregarding these
warnings may lead to personal injury or material damage. If this advice is disregarded, the manufacturer will not be
liable for damages that might occur.
Batteries, fuses and bulbs are excluded from warranty.
To avoid installation errors and damage to the gate and operator system, it is imperative that the installation
instructions are followed. The system may only be used after thoroughly reading the respective mounting and
installation instructions.
The installation and operating instructions are to be given to the gate system user, who must keep them safe.
They contain important advice for operation, checks and maintenance.
This item is produced according to the directives and standards mentioned in the Manufacturer's Declaration and in
the Declaration of Conformity. The product has left the factory in perfect condition with regard to safety.
Power-operated windows, doors and gates must be checked by an expert (and this must be documented) before they
are put into operation and thereafter as required, but at least once a year.
Correct use
The operator system is designed exclusively for opening and closing hinged doors and gates.
Gate requirements
The short version operator system - Comfort 520 is suitable for:
- hinged doors and gates with a gate wing width of 3 m and a gate wing weight of 400 kg.
The long version operator system - Comfort 520 L is suitable for:
- hinged doors and gates with a gate wing width of 4 m and a gate wing weight of 400 kg.
Beside the advice in these instructions, please observe the general safety and accident prevention regulations!
Our sales and supply terms and conditions are effective.
3. General safety advice
4 Manual for installation and operation, Comfort 520 accu GB (#89133)
Information on installing the operator system
• Ensure that the gate is in good mechanical condition.
• Ensure that the gate opens and closes properly.
• Remove all unnecessary components from the gate (e.g. cables, chains, brackets).
• Render any installations inoperable that will no longer be needed after the operator system has been installed.
• Before commencing cabling works it is very important to disconnect the operator system from the electricity supply.
Ensure that the electricity supply remains disconnected throughout the cabling works.
• Adhere to the local protection regulations.
• Lay the electricity supply cables and control cables; these MUST be laid separately. The controls voltage is 24 V DC.
• Install all the impulse transmitters and control devices (e.g. remote control buttons) within sight of the gate and at a
safe distance from the moving parts of the gate. A minimum installation height of 1.5 m must be observed.
• Ensure that no part of the gate extends across public footways or roads when the installation is complete.
Information on commissioning the operator system
After initial operation, the persons responsible for operating the gate system, or their representatives must be
familiarised with the use of the system.
• The rechargeable battery unit must be fully charged before the door system is put into operation.
• Make sure that children cannot access the gate control unit.
• Before moving the gate, make sure that there are neither persons nor objects in the operating range of the gate.
• Test all existing emergency command devices.
• Never insert your hands into a running gate or moving parts.
• Pay attention to any parts of the gate system that could cause crushing or shearing damage or accidents.
The EN 13241-1 regulations must be observed.
Information on servicing the operator system
To ensure proper operation, the following items must be checked regularly and repaired if necessary.
Before any works to the gate system are undertaken, the operator system must be disconnected from the mains.
• Check once a month that the operator system stops and reverses in every position when the gate touches an
obstacle. Place an obstacle in the path of the gate to check this.
• Check the settings of the OPEN and CLOSE automatic cut-out function.
• Check all movable parts of the gate and operator system.
• Check the gate system for signs of wear or damage.
• Check whether the gate can be easily moved by hand.
Information on cleaning the operator system
Never use water jets, high pressure cleaners, acids or bases for cleaning.
Please read carefully!
3. General safety advice
Manual for installation and operation, Comfort 520 accu GB (#89133) 5
4.1 Comfort 520 accu supply package
4. Product overview
4.1 / 1
1
2
Single wing gate system
(Short version – Comfort 520)
1 Motor unit with short connection cable (1.2 m)
2 Key (2x)
4.1 / 2
1
2
Single wing gate system
(Long version – Comfort 520 L)
1 Motor unit with short connection cable (1.2 m)
2 Key (2x)
4.1 / 3
3 Motor unit with short connection cable (1.2 m)
4 Motor unit with long connection cable (9.5 m)
5 Key (4x)
Double wing gate system
(Short version – Comfort 520)
3
4
5
4.1 / 4
3 Motor unit with short connection cable (1.2 m)
4 Motor unit with long connection cable (9.5 m)
5 Key (4x)
Double wing gate system
(Long version – Comfort 520 L)
3
4
5
The Comfort 520 standard delivery package comprises:
- motor unit
- controls
- fixing materials for controls
and motor unit
- remote control
The Comfort 520 is available in the following versions,
as required:
6 Manual for installation and operation, Comfort 520 accu GB (#89133)
4. Product overview
!#
!”
8
9
4.1 / 5
6 Control x.51 accu
7 Handle
4.1 / 6
8 Screws 3.5 x 32 (4x)
9 Wall plugs S6 (4x)
10 Spacer elements (2x)
11 Screw fixing insert with 2 flat cable openings
12 M20 screw fixing with flat cable insert
13 M20 screw fixing with round cable insert
14 M16 screw fixing with round cable insert
Control unit
Mounting kit for control unit
6
4.1 / 8
19 Wood screws 8 x 60 (4x)
20 Wall plugs S10 (4x)
21 Gate bracket
(short or long version)
22 Cover cap (3x)
23 M8 x 25 (6x)
24 Nuts M8 (6x)
25 Post bracke
Single wing gate system installation set
!
9
„¯
7
„Ø
4.1 / 7
15 Hand transmitter
16 Sun visor clip
17 Module antenna
18 Transmission plug
Remote control
5
!5
!^
!\
„”
„#
„£
Manual for installation and operation, Comfort 520 accu GB (#89133) 7
4. Product overview
19 Wood screws 8 x 60 (8x)
20 Wall plugs S10 (8x)
21 Gate bracket (2x)
(short or long version)
22 Locking plates (6x)
23 M8 x 25 (12x)
24 Nuts M8 (12x)
25 Post bracket (2x)
Double wing gate system installation set
4.1 / 9
4.1 / 10
!9
„¯
„Ø
5
„”
„#
„£
!
9
„¯
„Ø
5
„”
„#
„£
Battery operation version
28 Rechargeable battery unit
29 Cable loom of rechargeable battery unit
30 Plug mains supply
Solar version
31 Fixing bracket for solar module (2x)
32 Solar module incl. 7.5 m connection cable
33 Set of screws, M5 x 12, incl. M5 nuts (4x)
34 Set of screws, 8 x 45 (4x)
8 Manual for installation and operation, Comfort 520 accu GB (#89133)
4.1 / 11
“˜
4.1 / 12
§¯
“\
“^
“·
§»
§”
4. Product overview
4.3 / 1
The standard supply package is suitable for
the following types of gate.
Single wing gate system
4.3 / 2
Double wing gate system
4.3 Gate variations
4.2 / 1
Short version – Comfort 520
4.2 / 2
Long version – Comfort 520 L
4.2 Dimensions
78
428
72
74
120
358
633
811
114
ø12
ø10
M8
M8
52.5
78
548
72
74
120
478
753
931
114
ø12
ø10
M8
M8
52.5
Manual for installation and operation, Comfort 520 accu GB (#89133) 9
5.2 Checks
Attention!
In order to guarantee correct
mounting, carry out the following
checks before installing.
Supply package
• Check the package to ensure that all the parts are
included.
• Check that you have all the additional components
that are necessary for your particular installation
requirements.
Gate system *
• Ensure that your gate system has an appropriate
electricity supply connection and a facility
for disconnecting the mains. The minimum
cross-sectional area of the earth cable is
3 x 1.5 mm
2
.
• Ensure that all cables are suitable for outdoor use
(UV resistant and cold resistant).
• Ensure that your gate system has a gate stop in the
CLOSE and OPEN directions.
• Disassemble the door latches or render them
inoperable.
• Ensure that the gate can be easily moved by hand.
• Observe the following gate requirements.
Gate wing width:
- Comfort 520 min. 1 m - max. 3 m
- Comfort 520 L min. 1 m - max. 4 m
Gate height: max. 2.5 m
Gate wing weight: max. 400 kg
Open space: min. 50%
Gate incline: with accessories, max. 10%
(approx. 10 cm/m)
5. Preparation for mounting
5.1 General notes
The pictures in these instructions are not true-to-scale.
Dimensions are always given in millimetres (mm)!
The motor unit and the controls must be mounted on
the inside of the gate system.
For correct mounting you will need the following
tools:
13
ø 10
ø 6,5
13 2
2
5
M 8
ø 6
5.1 / 1
Advice:
The use of an electric lock is
recommended for a gate wing
wider than 2 m.
10 Manual for installation and operation, Comfort 520 accu GB (#89133)
* Dependent on the type of operator system used
5. Preparation for mounting
5.3 Cabling layout
5.3 / 1
2 x 0.75 mm
2
2 x 0.75 mm
2
2 x 0.4 mm
2
2 x 0.4 mm
2
2 x 0.4 mm
2
2 x 0.4 mm
2
3 x 1.5 mm
2
230 V / AC
3 x 1.5 mm
2
Advice:
This is just an example of a cabling layout; the layout can vary according to the type of gate and the
associated equipment.
Reference:
For the installation and cabling of the gate sensors, control elements and safety equipment, the relevant
installation instructions must be observed.
i
1 Photocell
2 Photocell
3 Signal light
4 Code button, transponder, ...
5 Key switch
6 Mains isolator switch (mains disconnection facility)
7 Electric lock
8 Stop plate
9 Mains supply cable
10 Cosing edge safety device (CESD)
11 Rechargeable battery unit
12 Solar module*
* Dependent on the type of operator system used
2
2
3
4
6
9
7
1
1
8
5
2 x 0.75 mm
2
!”
Manual for installation and operation, Comfort 520 accu GB (#89133) 11
6.1 Mounting conditions
6. Installation
The mounting positions of the gate bracket (C) and
the post bracket (D) are dependent on the current gate
situation.
The positions of the gate bracket (C) and the post bracket
(D) influence the following factors:
- Opening angle (n)
- Utilisation of the movement stroke (m)
- Gate travelling speed
A triangle of forces is formed by the gate pivot (A),
the post bracket pivot (B) and the gate bracket pivot (I).
6.1 / 1
C
B
D
A
n
m
E
6.1 / 2
Motor unit is parallel to the gate
6.1 / 3
Motor unit is in triangle of forces
Attention!
For trouble-free operation, choose the
positions of the brackets such that they
meet all following conditions:
- The motor unit must be located in a
triangle of forces and should not be
parallel to the gate at the OPEN and
CLOSED gate positions.
- The length of travel should be as
large as possible.
12 Manual for installation and operation, Comfort 520 accu GB (#89133)
6. Installation
6.1 / 4 6.1 / 5
D
D
F
A
A
Advice:
For hinged gates with a negative e value of 0 to -80 mm, the “Special 502” bracket extension must be
used (not included in the standard package).
Find dimension e
e
e
The type of post bracket required can be determined from dimension e.
e Distance from post bracket screw-plate to the gate pivot
A Gate pivot
F Screw plate of post bracket
Positive e value (Illustration 6.1 / 4)
The pivot (A) lies behind the screw-plate (F) of the post bracket (D).
The installation can be carried out using the components in the standard package.
Negative e value (Illustration 6.1 / 5)
The pivot (A) lies in front of the screw-plate (F) of the post bracket (D).
F
Manual for installation and operation, Comfort 520 accu GB (#89133) 13
6. Installation
Long version – Comfort 520 L
e = 100 - 200 mm / max. gate wing width 4 m / max. gate wing weight 400 kg
Short version – Comfort 520
e = 0 - 100 mm / max. gate wing width 3 m / max. gate wing weight 400 kg
6.2 / 1
f
C
x
A
e
B
D
e f x A B B1 1.BR 2.BR
0 f~e 20 - 50 125 122 500 x
25 f~e 20 - 50 125 147 500 x
50 f~e 20 - 50 125 172 500 x
75 f~e 20 - 50 130 162 510 x
100 f~e 20 - 50 130 187 510 x
e f x A B B1 1.BR 2.BR
100 f~e 20 - 50 200 222 560 x
125 f~e 20 - 50 195 212 570 x
150 f~e 20 - 50 195 237 570 x
175 f~e 20 - 50 180 262 575 x
200 f~e 20 - 50 170 287 585 x
D
2.BR
1.BR
Advice:
The information on the table is valid for an opening angle of 90°.
Tables of measurements
With the help of the dimension tables, the approximate position of the gate bracket (C) and the post bracket (D) at the
gate can be determined.
6.2 Installing the motor unit at the gate
B1
14 Manual for installation and operation, Comfort 520 accu GB (#89133)
6. Installation
6.2 / 2
• Determine the fixing points which are suitable for
your gate configuration by means of the table of
measurements.
• Align the angles horizontally.
• Fix the angles with screw clamps.
6.2 / 3
• Release the motor unit.
• Place the motor unit on the bracket.
6.2 / 4
Reference:
The motor unit release function is
described under 6.3.
i
• Open the gate up to the desired opening angle.
Tip:
For an easier determination of the
fixing points you can use the optional
mounting pattern for Comfort 520 or
Comfort 520 L.
Manual for installation and operation, Comfort 520 accu GB (#89133) 15
6. Installation
If all mounting conditions are correct, the positions of
the angles are defined.
If the mounting conditions are not correct, adjust the
gate travel.
6.2 / 5
The following alterations can be made to adjust the
travel of the gate.
- Select a different drill hole on the gate bracket (C)
and/or on the post bracket (D).
- Alter the horizontal position of the gate bracket.
- Alter the horizontal position of the post bracket.
• Adjust the gate travel in such a way that all the
mounting conditions are met.
M8 x 25
• Remove the motor unit from the angles.
• Lock the motor unit.
• Mark the drill hole locations on the gate and on the
post.
• Remove the screw clamps.
• Screw the gate bracket (C) to the gate at the
calculated position.
Reference:
The mounting conditions can be found
in chapter 6.1.
i
6.2 / 6
DC
C
16 Manual for installation and operation, Comfort 520 accu GB (#89133)
6. Installation
• Screw the post bracket (D) to the pillar at the
calculated position.
8 x 60
Mounting on a concrete or stone pillar
Mounting on a metal post
M8 x 25
• Screw the post bracket (D) to the post at the
calculated position.
M8
For double wing gate systems, the motor unit with the
short connection cable must be mounted on the same
side as the controls.
• Set the motor unit in the calculated drill holes in the
gate bracket and in the post bracket.
• Screw the motor unit tightly onto the angles.
• Push the cover caps (E) into the redundant drill holes
from above.
• For double wing gate systems, fix the second motor
unit accordingly on the other side.
6.2 / 8
6.2 / 9
E
Caution!
To avoid injuries, the drill holes in the
post bracket that are not required must
be fitted with cover caps (E).
6.2 / 7
D
D
Manual for installation and operation, Comfort 520 accu GB (#89133) 17
6. Installation
6.3 Release
Releasing
• Open the protective cap.
• Put the key into the lock and turn it 90° clockwise.
Locking
• Push the unlocking lever (A) up.
Attention!
The gate must be relocked in
the same position, in which it was
released!
Attention!
The releasing position of the gate must
be marked in order to ensure correct
locking.
6.3 / 1
6.3 / 2
6.3 / 3
6.3 / 4
• Push the unlocking lever (A) down.
The drive is now mechanically disconnected and the
gate can be moved by hand.
• Put the key into the lock and turn it 90° anticlockwise.
• Close the protective cap.
The drive is now mechanically connected and the gate
can be moved via the motor unit.
A
A
18 Manual for installation and operation, Comfort 520 accu GB (#89133)
6. Installation
6.4 / 1
• Open the control unit.
• Mount the control unit using the spacer elements (A).
3,5 x 32
Attention!
- The control unit must be installed in
such a way that the motor cable can
be fed through the screw fixing at the
base of the control unit.
- The rechargeable battery unit must be
protected by additional measures (e.g.
housing unit) against the effects of
the weather.
6.4 / 2
A
Manual for installation and operation, Comfort 520 accu GB (#89133) 19
6.4 Fixing the control unit
Reference:
For the installation and cabling of the
rechargeable battery unit and the solar
module, the relevant installation
instructions must be observed.
i
6.5 Connection of control elements
Attention!
In order to avoid damaging the
controls:
- The local safety regulations must be
complied with at all times.
- It is very important that mains cables
are laid separately from control cables.
- The controls voltage must be 24 V DC.
- If external voltages are applied at
terminals XM70A, XV51A, XM70B,
XV51B, XB99, XP54B, XP54A, XP62B,
XP62A or XB70, the entire electronic
system will be destroyed.
- Only potential-free contacts may be
connected to terminals B9, 5, 34, 3
and 8 (XB99).
Caution!
Danger of electric shock:
Before any cabling works begin, it must
be ensured that the cables are
disconnected from the power supply.
During cabling works, it must be
ensured that the cables remain
disconnected from the power supply at
all times (e.g. prevent reconnection).
Reference:
When installing external control
elements, or safety and signal
equipment, the relevant instructions
must be observed.
i
Label Type / function
i
XB70 Connection of modular antenna 8.1
XB99
Connection of external control
elements
6.5 / 2
6.5 / 3
6.5 / 4
6.5 / 5
XH01
Connection for programmable
output 16/17 (e.g. signal light,
24 V DC, 0,5 A)
Wiping impulse 15/16
6.5 / 6
6.5 / 7
XM70A
Connection for motor unit
(MASTER)
6.6 / 5
6.6 / 8
XM70B
Connection for motor unit
(SLAVE)
6.6 / 5
6.6 / 8
XN70 Connection of battery -
XN81 Connection has no function -
XP54A
Connection for closing edge
safety device, gate travelling
direction CLOSE
6.5 / 8
XP54B
Connection for closing edge
safety device, gate travelling
direction OPEN
6.5 / 8
XP62A
Connection for photocell,
gate travelling direction CLOSE
6.5 / 9
XP62B
Connection for photocell,
gate travelling direction OPEN
6.5 / 9
XV51A
Connection for rpm detector
and reference point sensor
(MASTER)
6.6 / 5
6.6 / 8
XV51B
Connection for rpm detector
and reference point sensor
(SLAVE)
6.6 / 5
6.6 / 8
P
1
2
3
4
5
6
7
8
1
2
L
N
PE
15
16 17
6.5 / 1
XN81
XV51B
XM70B
XM70A
XV51A
XB99
XP54A
XB70
XP54B
XH01
XP62A
XN70 XP62B
20 Manual for installation and operation, Comfort 520 accu GB (#89133)
6. Installation
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Marantec Comfort 520 Control x.51 accu Owner's manual

Category
Gate Opener
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI