  • Hello! I am an AI chatbot trained to assist you with the MicroNet SP5208 Quick Installation Guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What is Micronet SP5208?
    What are the features of Micronet SP5208?
    How do I connect my device?
    What do the LED indicators signify?
    How do I log in to the system?
5
Quick Installation Guide
IP PBX Gateway
Model No.: SP5208
6
Network Configuration
Step 1: Go to [ Network Configuration > WAN Setting ], and
select the right connection type (static IP, DHCP, or
PPPoE) according to your ISP or actual network.
Step 2: Press the Apply button after you finish configuration.
Step 3: [ ],
Step 1:
Step 1:
Go to Reboot and click Reboot .
Service Registration
Step 1: Go to [Service > SIP Trunk ] and set the server
information here, if this VoIP gateway wants to use SIP
Proxy service to transfer the VoIP call.
Step 1:
Step 1:
P/N: 2300-0560
7
WEEE Directive & Product Disposal
At the end its serviceable life ,this product should not be treated
as household or general waste. It should be handed over to the
applicable collection point for the recycling of electrical and
electronic equipment, or returned to the supplier for disposal.
Note: You can retrieve the IP address of the WAN port by
keying #126# on the phone set that is connected to
the FXS port of the gateway. You will hear an IVR
announcing the current IPaddress of the WAN port.
Note:
Note:
Note:
Line Number: Specify the SIP line number
User ID: Specify SIP account
Password: Set password of SIP account
Primary SIP Proxy Server / Port: Specify the IP address,
port number and the default port number is 5060
Primary SIP Domain: Specify the Domain name
Primary Outbound Proxy Server / Port: Specify the IP
address, port number and the default port number is 5060
tep 2: Press the Apply button after you finish configuration..
Step 3: Go to [ Reboot ] and click reboot
S
Note: Please refer to user's manual for more details.
Basic Operation
Extension
Calling
SIP Calling
PSTN/GSM
Calling
Call Hold
Call
Transfer
Hook off, and dial <line number + #> to n-th extension.
Note: 1. Default line numbers are 21, 22, 23, 24, 25, 26
2. Go to [ Service > Extension Line ] for
modification.
Hook off, and dial <telephone number + #>.
Note: Please operate after finishing SIP trunk
configuration.
Hook off, and dial <telephone number + #>.
Note: 1. Go to [ Service > PSTN Line ], and configure
specific prefix for PSTN/GSM calling, as long
as SIP registered.
2. The change is applied after reboot.
Press Hook or Flash to hold
Press Hook or Flash again to resume
While in conversation of Party A and B, Party B may
press Hook or Flash to hold the call
Part B hear a dial tone, and dials <Party C number
+ #> to talk with Party C
Hang up from Party B, and then Party A will transfer
and connect to Part C.
Web: www.micronet.com.tw ; www.micronet.info
Introduction
Micronet SP5208 IP PBX Gateway is an innovative VoIP gear
that provides 6 FXS ports for extension calling and SIP trunk for
inbound/outbound calls via ITSP/ISP. Users can benefit from
VoIP via built-in PBX functionalities, such as automated
attendant, operator, SIP/PSTN trunk, dial plan, etc, that are
supported by the ease-to-use device.
In addition, SP5208 supports 2 FXO ports to connect with
PSTN lines which are subscribed for company's representative
telephone number. By just connecting FXO ports, users can
make/receive calls via PSTN lines with default configuration.
Company with IP-based platform still can receive daily phone
calls from PSTN or GSM, if the direct calling with PSTN number
to VoIP network is not supported by ITSP/ISP. SP5208 also
provides PSTN backup by FXO connections, even if network or
power fails. With the smart designs, SP5208 is a perfect VoIP
solution to small business customers.
Package Contents
Before you start installing the device, verify the following items
are in the package:
IP PBX Gateway
Quick Installation Guide
Manual CD
Power Adapter
4
1 2
3
Key Features
IETF SIP standards compliant
Support extension calling among 6 FXS ports
Support 2 FXO ports to connect with PSTN lines
Support SIP trunk for inbound/outbound SIP calls via
ITSP/ISP
Support prefix routing for outbound calling via PSTN or SIP
trunk
Support simple IVR / automated attendant and operator
setting
Support PSTN backup for power/register failure
Provide convenient call features: call hold, call transfer, and
call forward
Well interoperability with industry-leading IP-PBX/Soft-Switch,
such as Alcatel, Lucent, Siemens, etc.
Physical Description
SP5208 IP PBX Gateway
LED Status Indication
The Power is on
Booting up for self test
Gateway reg. fails
Gateway reg. successes
Transmitting or receiving data /
Network connection established
Transmitting or receiving data /
Network connection established
Busy / Off-hook
Available / On-hook
Busy
Available
LED Indicators
POWER
READY
PROXY
WAN
LAN(1-4)
T1-T6
L1-L2
On / Green
Blink / Green
Blink / Green
Constant / Green
Blink / Green
Blink / Green
On / Orange
Off
On / Orange
Off
Installation
Micronet gateway that you have purchased determines the
interfaces that you see on the rear of your unit. Just connect
your device using its telephony, power and LAN connections.
LAN
WAN
T1-T6
L1- /L2
RESET
DC 12V
Connect to your PC
Connect to the internal LAN network, router,
or modem
FXS(T) / FXO(L) RJ-11 ports. FXS ports are used
to connect to telephones or PABX's trunks. FXO
ports are used to connect to PSTN line or
PABX's extensions.
Factory and hold over 5 seconds Reset button
Power adapter connection
Login the System
Set your PC with static IP address (192.168.123.x) and mask
(255.255.255.0), or DHCP mode to get IP address automatically.
Launch web browser with http://192.168.123.123/. Then, login
with username (root) and password (no password).
/