BEISIT F500 User manual

Type
User manual

BEISIT F500 is a UHF RFID reader that supports EPCglobal UHF Class 1 Gen 2/ISO 180006C and ISO 18000-6B protocols. It has a working frequency range of 860~960MHz and can be used in FCC, ETSI, and CN regions. The RF power is adjustable from 5 to 30dBm in 1dB steps, and the receiving sensitivity is <-78dBm. The reading distance is >3.5m, and the reading speed is >400 PCS/second. The BEISIT F500 has a working current of <500mA@24V and a standby current of <20mA@24V. It supports RS-232 and RS-485 communication interfaces and has 4PIN Green(+RS-485), DB-9, and 5 SMA

BEISIT F500 is a UHF RFID reader that supports EPCglobal UHF Class 1 Gen 2/ISO 180006C and ISO 18000-6B protocols. It has a working frequency range of 860~960MHz and can be used in FCC, ETSI, and CN regions. The RF power is adjustable from 5 to 30dBm in 1dB steps, and the receiving sensitivity is <-78dBm. The reading distance is >3.5m, and the reading speed is >400 PCS/second. The BEISIT F500 has a working current of <500mA@24V and a standby current of <20mA@24V. It supports RS-232 and RS-485 communication interfaces and has 4PIN Green(+RS-485), DB-9, and 5 SMA

UHF RFID Reader
Product model: F500
TEL:+86-571-8936 2888 Email:info@beisit.com Http:// www.beisit.com
ANT 5 ANT 1
ANT 2
ANT 4
ANT 3
Product Picture:
Technical characteristics:
Transponder
Protocol
EPCglobal UHF Class 1 Gen 2/ISO 18000-
6C、ISO 18000-6B (Options)
Working Current
<500mA@24V
Standby Current
<20mA@24V
Working Frequency
860~960MHz
Communication
RS-232、RS-485
Working Region
FCC 902-928 MHz ETSI 865.6-867.6 MHz CN
920-925MHz Other Area can be set up
Interface
4PIN Green(+RS-485) ,DB-9, 5 SMA RF
Connector
RF POWER
5~30dBm(1dB Step adjustable)
Operating Temperature
-25℃ to 65℃
Receiving Sensitivity
<-78dBm
Storage Temperature
-40℃ to 85℃
RF Accuracy
±1dB
Relative Humidity
10% - 95%
Flatness Of RF Power
±0.2dB
Coling Type
Air Cooling
Reading Distance
>3.5m(According to different tag)
Dimensions(W x H x D)
102.0*67.0*17.5mm
Reading Speed
>400 PCS/second
Weight
<115g
LED Indicator
Support
Housing Material
Aluminum alloy
RSSI
Support
Approval
FCC、CE、RoHS
Ambient Temperature
Monitoring
Support
Software Development
Materials
SDK & API
Working Voltage
DC 9~24V
TEL:+86-571-8936 2888 Email:info@beisit.com Http:// www.beisit.com
Antenna interface:
ANT1:
SMA
DC9~24
V:
DC Power, voltage range9~24V
ANT2:
SMA
GND:
Signal&Power reference GND
ANT3:
SMA
485 A:
Com RS-485A Signal
ANT4:
SMA
485 B:
Com RS-485B Signal
ANT5:
SMA
RS232
Standard D9 serial port
LED Indicator Description
Tricolour light:
Red Lamp — Power,Blue Lamp — On-Reading,Green Lamp — Flash Got Tag。
Announcements:
Do not open the software when the antenna is not connected,
otherwise no load may damage the reader!
Dimensions
TEL:+86-571-8936 2888 Email:info@beisit.com Http:// www.beisit.com
!FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body.
TEL:+86-571-8936 2888 Email:info@beisit.com Http:// www.beisit.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

BEISIT F500 User manual

Type
User manual

BEISIT F500 is a UHF RFID reader that supports EPCglobal UHF Class 1 Gen 2/ISO 180006C and ISO 18000-6B protocols. It has a working frequency range of 860~960MHz and can be used in FCC, ETSI, and CN regions. The RF power is adjustable from 5 to 30dBm in 1dB steps, and the receiving sensitivity is <-78dBm. The reading distance is >3.5m, and the reading speed is >400 PCS/second. The BEISIT F500 has a working current of <500mA@24V and a standby current of <20mA@24V. It supports RS-232 and RS-485 communication interfaces and has 4PIN Green(+RS-485), DB-9, and 5 SMA

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI