Fadini DGT 61 Owner's manual

Type
Owner's manual
Instructions Manual
5
3
1
code 558
code 552
code 554
code 552
DGT 61
page 8
Pic.1
GREEN LED:
access code OK
RED LED: wrong access code
or STOP button activated
Digital keypad
meccanica
FADINI
BRINGING THE KEYPAD APART
Item 610
Surface keypad
Item 611
Partial recess keypad
ENGLISH
1
2
3
4
5
6
7
8
9
A
B
S
TO
P
1
2
3
4
5
6
7
8
9
A
B
STOP
F
A
D
I
N
I
1
2
3
4
5
6
7
8
9
A
B
S
T
O
P
Item 612
Main Printed Circuit Board
Instructions manual DGT 61 digital keypad
GB
DGT 61
12-24V
cc/ca
AB
NC
X
Y
Z
1
2
3
4
5
6
7
8
9
A
B
S
T
O
P
1
2
3
4
5
6
7
8
9
A
B
STOP
DISPOSITIVO SONORO
1
2
3
4
5
6
7
8
9
A
B
STOP
Sech 15
Prit 19
code 553
code 560
F
A
D
IN
I
BLUE LED:
 Fixed light: - unit on voltage
- night illumination of the keypad
 Flashing light: professionaly advanced timed functions
in progress
!
This unit is recommended to be installed in a
safe and sheltered place
DGT 61
12-24V
cc/ca
AB
NC
X
Y
Z
Pic.2
BRINGING THE MAIN PCB APART
Pic.3
ACCESSORIES TO FIT THE KEYPAD, RECESS APPLICATION
Pic.4
SURFACE APPLICATION OF THE KEYPAD TO A WALL
Pic.5
LED LIGHTS
1
2
3
4
5
6
7
8
9
A
B
S
T
O
P
F
A
D
I
N
I
Pic.6
SOUND DEVICE
made in Italy
the gate opener
GB
Long Beep: a long beep confirms the
correct access code sequence
n°3 short beeps: the access code
sequence is wrong
n°5 short beeps: memory clearing carried out
correctly
n°1 short beep: is emitted whenever
a key button is pressed
Stainless steel
front cover
Treated
aluminium
front unit
Keypad
Treated aluminium
back casing
surface mount
Plastic back casing
recess mount
Directive 2003/108/CE
Disposal of electric and
electronic material
DO NOT DISPOSE OF AS
NORMAL WASTE - HARMFUL
FOR THE ENVIRONMENT
GB
page 7
NOTE: screws and expanding bolts not supplied by us.
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set
only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is through
the first four DIp-switches that different ACCESS CODES can be stored).
The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press A.
The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
= Pure contact for STOP function only: direct to
the relay in case of an emergency
NOTE: The relay A can take up to 4 different access codes max. Each code
is to be stored individually by setting any one of the first 4 DIP-switches to ON.
PLEASE NOTE: THIS OPERATION ERASES COMPLETELY ALL THE ACCESS CODES AND ANY ADDITIONAL FUNCTIONS STORED WITH THE RELAY
INVOLVED IN THIS PROCESS.
Carry out the electrical connections to the keypad, main PCB and the Elpro
control box (or to a control relay). Pic. 8.
The DGT 61 keypad incorporates also a pure NC contact to get the STOP
function. The contacts of the C - NC terminals on the main PCB are opened
on pulsing the STOP button in the keypad, and no code is required to be
entered.
Once satisfied that the main PCB is properly connected to the Elpro control
box, and the selected ACCESS CODES stored with the required output, to operate
with the keypad just press the keys corresponding to the ACCESS CODE, followed
by the key corresponding to the required OUTPUT (A or B).
The green led goes on followed a long confirming beeping.
1) Set the Dip-sw. 10 to ON. The red led 1
flashes.
2) Press the key 9 9 9 (three times).
3) Press button A or B to erase the encoding
and the functions from output A or B
4) Set all the DIP-switches to OFF.
5 short beeps confirm the operation
while the green led keeps flashing as
long as beeping can be heard.
!
1)
2)
1)
2)
3)
OFF
1) 3) 4)
1
Diagram
Diagram
ingresso
automatizzato B o
altre utenze
12-24Vac/dc
XYZ
XYZ
12345678910
AB
XYZ
13 14
3 4 6
XYZ
Keypad DGT 61 Keypad DGT 61
3 4
14
13 13
14
3
33
NCC
XYZ
A
B
S
S
ON
OFF
ON
OFF
S
5
12345678910
(*)
(*)
(*) The connection
to Z terminal is
required in case of
weak or disturbed
signal
(*)
STOP
1**
ON
ON
3**
ON
4**
ON
2**
ON
ON
ON
ON
**once encoding/programming phases are completed, all Dip-switches are to be set to OFF
1**
2**
3**
4**
1
ON
STOP
ON
10
OFF
10
2)
1
23
456
789
A
B
1) Carry out the electrical connections to the MAIN PCB (Pic.8).
2) Set
only one of the switches DIP 1 or DIP 2 or DIP 3 or DIP 4 to ON (It is through
the first four DIp-switches that different ACCESS CODES can be stored).
The red led 1 on the main PCB flashes.
3) Press the ACCESS CODE (from 1 to 6 digits) - press B.
The green led goes on followed by a long confirming beep.
4) Set all DIP-switches to OFF. The red led 1 on the PCB goes off.
NOTE: The relay B can take up to 4 different access codes max. Each code
is to be stored individually by setting any one of the first 4 DIP-switches to ON.
OFF
1) 3) 4)
1
1
ON
2)
1
23
456
789
1
23
456
789
oppure
A
B
3
If the access code sequence is
incorrect: the unit gives out 3
beeping souds and the red led
illuminates for 2 seconds.
Dial correctly or reprogram the unit.
9 9 9
A
B
A
B
(*)
DGT 61
1
2
-2
4
V
c
c
/c
a
AB
N
C
X
Y
Z
STOP
1
23
456
789
A
B
FADINI
STOP
1
23
456
789
A
B
FADINI
STOP
1
23
456
789
A
B
FADINI
12-24V
ac/dc
12-24V
ac/dc
DGT 61 is a custom-encoded control accessory designed to open and close any automatic access system. It can be also used to control other external
applications. DGT 61 consists of a Keypad (in an anti-corrosion treated aluminium casing, in two options either to be partially recessed or surface mounted)
cable connected (x 4 wires) to the Main PCB; this one is to be installed near the Elpro electronic control box for the electrical connections. The keypad
incorporates the button keys, illuminated in blue from the back: nine digits, two outputs A and B and one output for the emergency stop button. The main PCB
is fitted with a terminal block where power supply is to be connected (in parallel also to the keypads), with the N.O. contacts of the A and B output relays
and with one pure N.C. terminal output of a third relay, providing connections for an emergency stop. A second block of terminals X and Y (and a third
one Z for long distance or disturbed signals) receive the encoded signal from the keypads. Programming is simple and immediate by Dip-switches on
the main PCB. Each channel can take up to 4 different numerical codes; any one code, through the same channel either A or B, operates the same
function. Other professionally advanced functions can be achieved by the two relays (bistable outputs, timed bistable outputs, output delay, etc.), and
can be enabled by the Dip-switches on the main PCB. Other external control applications are also made possible (eg. illumination, alarm systems and
watering) besides automatic door/gate systems, etc.
In these cases, it is recommended that a relay be always fitted between the PCB and the other possible applications.
Pic.7
meccanica
FADINI
GENERAL DESCRIPTION
Instructions manual DGT 61 digital keypad
GB
Pic.8
DIAGRAM OF A POSSIBLE INSTALLATION WITH TWO KEYPADS AND ONE PCB
meccanica
FADINI
Instructions manual DGT 61 digital keypad
GB
STORING ONE OR MORE ACCESS CODES ONTO THE RELAY OUTPUT A
STORING ONE OR MORE ACCESS CODES ON O THE RELAY OUTPUT B
HOW TO OPERATE WITH DGT 61 KEYPAD
ENABLING THE STOP BUTTON KEY
MEMORY CLEARING
Diagram
Diagram
Diagram
page 9 page 10
1st CODE
to relay B
2nd CODE
to relay B
3rd CODE
to relay B
4th CODE
to relay B
1st CODE
to relay A
2nd CODE
to relay A
3rd CODE
to relay A
4th CODE
to relay A
Automated
access A or
other applications
Controll box series
Elpro - access A
Controll box Elpro 6 -
access B
common
common
open
stop
open/stop/close
24Vac/dc
stop
open
open
relay NO
CNO NOCNCC
max 0.5mm²
up to 100m
main PCB
24V
ac/dc
0.5mm² up to 100m
1 or more
keypads DGT 61
Main PCB
max 0.5mm² up to 100m
(*) the connection to the
Z terminal is required in
case of weak or
disturbed signal
12-24V
ac/dc
Red led 1:
It flashes during
programming phase
Red led 2: It flashes slowly
when X Y are properly connected
to the keypad
Jumper for 12Vdc power supply:
when jumper is fitted, 12Vdc power
supply is possible
relay NCrelay NO
CNO NOCNCC
relay
NCrelay N0relay N0
ACCESS
CODE
LONG
BEEPING
green led
for 1 second
A or B output
Main PCB
red led
for 2 seconds
press
STOP
pure contact
relay A
ALL DIP-SW.
TO OFF
Main PCB
Main PCB
ACCESS
CODE
relay B
ALL DIP-SW.
TO OFF
Main PCB
Main PCB
ACCESS
CODE
n°3 short beeps
Red led
for 2 seconds
Main
PCB
main PCB
keypad
A or B output
n°5 Beeps
green led
ALL DIP-SW.
TO OFF
or
4)
Programming:
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation delay as
required (max.1439 minutes).
3) Press output A or B through which the required function is activated.
4) Set all the DIP-switches to OFF
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
ON
1)
5
2) 3)
OFF
4)
5
OUTPUT DELAY
The pulse is delayed (for a number
of minutes) after pressing the
access code.
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
1
23
456
789
A
B
Diagram
Each pulse by the access code
energizes or de-energizes the
output relay.
Each pulse by the access code
delays (for a number of minutes)
the energizing of the timed relay.
pulse
output
TIMED WITH 2 PULSES
A pulse is given after the access code
has been pressed and another one
is given after a set time (minutes)
ON
1)
6
2) 3)
OFF
4)
6
BISTABLE
Connect the main PCB to the control box (Pic. 8) or to the external control relay, then store an access code with required outputs.
Different functions can be achieved by one or both of the outputs, but different access codes to one relay carry out the same function.
NOTE WELL: functions are reset in case of a power failure, even if instantaneous.
ON
1)
7
2) 3)
OFF
4)
7
TIMED DELAY
WITH 2 PULSES
1)
ON
8
2) 3)
OFF
8
4)
5)
The relay is energized and remain
energized for the time as set
(in minutes).
ON
1)
9
2) 3)
OFF
4)
9
6)
Steps to cancel the additional functions from the single relay and set the
DGT 61 unit back to normal functioning.
1)
ON
5
2)
OFF
5
3)
Programming:
1) Set DIP-sw. 6 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes for the time required after the first pulse
(max. 1439 minutes).
3) Press either A or B output by which the function is to be activated.
4) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
1
23
456
789
A
B
Diagram
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
Diagram
7
A
B
Programming:
1) Set DIP-sw. 7 to ON. The red led 1 on the PCB flashes.
2) Press only the button key No. 7.
3) Press either A or B output by which the required function is to be actived.
4) Set all the DIP-switches to OFF
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beeping.
Programming:
1) Set DIP-sw. 8 to ON. The red led 1 flashes.
2) Press the number of minutes for the delay with time 1 (max 1439 minutes)
3) Press either A or B output by which the required function is to be activated.
4) Press the numer of minutes for time 2 (max. 1439 minutes).
5) Press ether A or B as set in step 3).
6) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
Diagram
A
B
A
B
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
Programming:
1) Set DIP-sw. 9 to ON. The red led 1 on the PCB flashes.
2) Press the number of minutes corresponding to the activation time as
required (max. 1439 minutes).
3) Press output A or B as required for the function to be activated.
4) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
Using the function:
Press the access code followed by A or B as programmed. The green led
goes on for 1 sec. followed by an activation beep.
The blue led starts flashing and indicates that the function has been activated.
1
23
456
789
or
A
B
In order to RESET (the function is cancelled) press the following sequence:
A or B - access code - A or B
The green led goes on for 1 sec. followed by a confirmation beep, while
the blue led stays illuminated.
Diagram
Diagram
A
B
1
23
456
789
REMOVING THE ADDITIONAL FUNCTIONS
1) Set DIP-sw. 5 to ON. The red led 1 on the PCB flashes.
2) Press A (or B) - access code - press A (or B).
3) Set all the DIP-switches to OFF.
Confirmation of the operation: long beep and green led alight for 2 sec.
A
B
Power supply 2x0.5mm²
Connections to the keypad
Keypad absorption
Stand-by relay absorption
Energized relay absorption
Working temperature
N.O. channels
N.C. channels
Communication distance
Output contacts
kaypad protection standards
PCB protection standards
12-24Vdc/ac
4 x 0.5mm²
15 mA
4 mA
27 mA
-20° +80°C
2
1
max 100 m
1A-125V-60VA
IP 54
IP 53
meccanica
FADINI
ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
Instructions manual DGT 61 digital keypad
GB
meccanica
FADINI
Instructions manual DGT 61 digital keypad
GB
ADDITIONAL FUNCTIONS: can be achieved by the A and B outputs through one or more access codes
TIMED BISTABLE
OVERALL DIMENSIONS
TECHNICAL DATA
The manufacturer reserves the right to change this manual
without prior notice, and is not liable for incorrect applications
or damages to persons and properties.
Pic.9
page 11
page 12
main PCB
time in minutes
(max 1439 = 24h)
ALL DIP-SW.
TO OFF
main PCB
or
output
Time 1
pulse
output
Time 2
Time
pulse
output
main PCB
time in minutes
(max 1439 = 24h)
ALL DIP-SW.
TO OFF
main PCB
or
output
main PCB
press key 7
ALL DIP-SW.
TO OFF
main PCB
or
output
Time
pulse
output
main PCB
time 1 in
minutes
(max 1439)
ALL DIP-SW.
TO OFF
keypad
time 2 in
minutes
(max 1439)
keypad keypad
or
or
Time
pulse
output
main PCB
time in minutes
(max 1439 = 24h)
ALL DIP-SW.
TO OFF
main PCB
output
ALL DIP-SW.
TO OFF
LONG BEEP
gree led
for 2 seconds
or
main
PCB
output access
code
or
output
main
PCB
Manufacturing company:
The model:
DECLARES UNDER ITS OWN RESPONSIBILITY THAT:
DECLARATION OF CONFORMITY
of the manufacturer
DGT 61 is a digital keypad designed to be sold and installed into a comprehensive "Automatic System",
including the original accessories and components as recommended by the Manufacturing Company.
The installer must issue the Installer's Declaration of Conformity and carry out all the tests required to
comply with the existing regulations.
The manufacturing company is not liable for any incorrect use of its product.
The product conforms with the following norms as specified below:
- Low Voltage Directive
2006/95 CE
- Electro-magnetic Compatibility Directive
2004/108/CE and 92/31 CEE
GB
DGT 61
made in Italy
the gate opener
Date:
20 - 04- 11
meccanica
FADINI
Meccanica Fadini s.n.c.
Direttore Responsabile
The responsible manager
Via Mantova 177/A - C.P. 126 - 37053 Cerea (VR) Italy
Tel. +39 0442 330422 - Fax +39 0442 331054
e-mail: [email protected] - www.fadini.net
DGT 61
1
2
-2
4V
c
c
/c
a
AB
N
C
X
Y
Z
91
73
27
Main
PCB
Surface mount
keypad
40
72
74
1
23
456
789
AB
STOP
FADINI
Keypad
29 25
54
Ø56
Recess mount keypad
  • Page 1 1
  • Page 2 2
  • Page 3 3