LST 2251TEM User manual

Type
User manual

LST 2251TEM is an addressable multisensor that combines optical and thermal detection technologies to reliably detect fire in various applications. Its advanced algorithms analyze both scattered light and thermal characteristics, enabling it to distinguish between real fires and deceptive alarms.

With adjustable sensitivity levels from 1.5%/m to 5.2%/m, you can customize the detector's response to suit your specific environment. It also features a thermal-only mode, allowing you to disable the optical detection for specialized applications.

The LST 2251TEM seamlessly integrates with System Sensor/200 protocol, ensuring constant communication with the fire detection control panel for regular function testing. Its intelligent evaluation algorithms compensate for contamination, maintaining consistent response sensitivity over time.

LST 2251TEM is an addressable multisensor that combines optical and thermal detection technologies to reliably detect fire in various applications. Its advanced algorithms analyze both scattered light and thermal characteristics, enabling it to distinguish between real fires and deceptive alarms.

With adjustable sensitivity levels from 1.5%/m to 5.2%/m, you can customize the detector's response to suit your specific environment. It also features a thermal-only mode, allowing you to disable the optical detection for specialized applications.

The LST 2251TEM seamlessly integrates with System Sensor/200 protocol, ensuring constant communication with the fire detection control panel for regular function testing. Its intelligent evaluation algorithms compensate for contamination, maintaining consistent response sensitivity over time.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
2251TEM_DBL_LST_EN_0819.PDF • PAGE 1
ABuilding Safety. Building Security.
Multisensor
2251TEM
Description
The addressable Multisensor 2251TEM uses the
scattered light principle as well as a separate thermal
detection unit. It was developed to detect the charac-
teristics of re in a wide range of applications, and to
avoid deceptive alarms. The modern design of both
measurement systems and the analysis of the parame-
ters by means of a special algorithm allow to reliably
evaluate the characteristics of fi re.
The sensitivity of the detector can be individually adjus-
ted in 5 steps between 1.5%/m and 5.2%/m according
to the application. Three steps have a fi xed sensitivity,
whereas two self-learning steps automatically adjust the
sensitivity to short-term changes of the environmental
conditions. Furthermore, the optical detection unit can
be completely disabled for a thermal-only operation.
The proven ADM loop technology with System Sen-
sor/200 protocol establishes a permanent communi-
cation between the re detection control panel and the
detector. That ensures a periodical function testing of
the detector.
The infl uence of contamination on the optical measu-
rement system is compensated for by using intelligent
evaluation algorithms. With that, the response sensiti-
vity of the detector is kept constant for a long time –
a further effective step to avoid false alarms.
The two LEDs with 360° visibility indicate the activated
condition of the detector. The detector address is se-
lected with two decadic rotary switches, thus allowing
to change the detector without additional tools.
A detector function test can be conveniently conducted
using a magnet. The detector can be attached to va-
rious bases and it can be protected against theft.
ADM loop technology with
System Sensor/200 protocol
Combination of optical and thermal
characteristics of fi re
Two self-learning and three fi xed
sensitivity levels
Thermal-only operation
Constant response sensitivity
Function testable with magnet
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27
[email protected] • WWW.LST.AT • ALL RIGHTS RESERVED
2251TEM_DBL_LST_EN_0819.PDF • PAGE 2
ABuilding Safety. Building Security.
Specifi cations
Operating voltage Supply through loop voltage
Current consumption typ. 250µA (quiescent)
Alarm temperature 57°C (maximum-heat component)
Operating temperature max. +45°C
Ambient temperature -20°C to +60°C (no condensation or icing)
Relative humidity 10 – 93% (no condensation)
Dimensions ø × H 102 × 45 (mm)
Colour cream
Weight 115g
Approvals VdS G201041
At operation in thermal-only mode:
EN 54-5 Class A1R 57°C maximum and rate-of-rise activation
Room height max. 7.5m
Order number 241020
Order name Optical-Thermal Detector/Anal./200/SS 2251TEM
  • Page 1 1
  • Page 2 2

LST 2251TEM User manual

Type
User manual

LST 2251TEM is an addressable multisensor that combines optical and thermal detection technologies to reliably detect fire in various applications. Its advanced algorithms analyze both scattered light and thermal characteristics, enabling it to distinguish between real fires and deceptive alarms.

With adjustable sensitivity levels from 1.5%/m to 5.2%/m, you can customize the detector's response to suit your specific environment. It also features a thermal-only mode, allowing you to disable the optical detection for specialized applications.

The LST 2251TEM seamlessly integrates with System Sensor/200 protocol, ensuring constant communication with the fire detection control panel for regular function testing. Its intelligent evaluation algorithms compensate for contamination, maintaining consistent response sensitivity over time.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI