Greetings
Thank you for purchasing the Mylex AcceleRAID™ 352 disk array controller. Requests
for technical information about this and other Mylex Corporation products should be
made to your Mylex authorized reseller or Mylex marketing representative.
Please Notice
IBM, Mylex, AcceleRAID, RAID EzAssist, Global Array Manager, and GAM are
trademarks or registered trademarks of International Business Machines Corp. and its
subsidiaries. Microsoft, MS-DOS, Windows 95, Windows 98, Windows NT, and Windows
2000 are registered trademarks of Microsoft Corporation. Novell and NetWare are a
registered trademarks of Novell Corporation. SCO and UnixWare are registered
trademarks of Santa Cruz Operations. Other names that are trademarks may be used herein
for the purpose of identifying the products or services of their respective owners.
Unless otherwise noted, companies, names and data used in examples herein are fictitious.
Our Policy
Although reasonable efforts have been made to assure the accuracy of the information
contained herein, this publication could include technical inaccuracies or typographical
errors. Mylex Corporation expressly disclaims liability for any error in this information,
and for damages, whether direct, indirect, special, exemplary, consequential or otherwise,
that may result from such error, including but not limited to loss of profits resulting from
the use or misuse of the manual or information contained therein (even if Mylex
Corporation has been advised of the possibility of such damages). Any questions or
comments regarding this document or its contents should be addressed to Mylex
Corporation at the address shown on the back cover.
The following paragraph does not apply to the United Kingdom or any country where such
provisions are inconsistent with local law:
MYLEX CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT
WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
Some states do not allow disclaimer of express or implied warranties or the limitation or
exclusion of liability for indirect, special, exemplary, incidental or consequential damages
in certain transactions; therefore, this statement may not apply to you. Also, you may have
other rights which vary from jurisdiction to jurisdiction.
Information in this publication is subject to change without notice and does not represent a
commitment on the part of Mylex Corporation. Changes may be made periodically to the
information herein; these changes will be incorporated in new editions of the publication.
Mylex Corporation reserves the right to make improvements and/or changes at any time in
the product(s) and/or program(s) described in this publication.
It is possible that this publication may contain reference to, or information about, Mylex
Corporation products (machines and programs), programming or services that are not
announced in your country. Such references or information must not be construed to mean
that Mylex Corporation intends to announce, provide, or make available such Mylex
products, programming, or services in your jurisdiction.
About This Manual
This installation guide covers hardware set-up and configuration procedures
necessary for the installation of a Mylex AcceleRAID 352 dual channel
RAID controller.
Chapter 1 describes the controller, standard package contents, and user-
supplied items necessary for installation.
Chapter 2 describes the steps to be performed prior to controller installation
and the physical installation of the AcceleRAID 352 dual channel RAID
controller.
Chapter 3 describes controller start-up and the BIOS options.
Appendix A describes the memory and battery backup module.
Appendix B provides hardware and environmental specifications.
Appendix C describes error messages and problem correction.
Appendix D describes the PCI Hot Plug feature.
Appendix E provides enclosure management information.
Appendix F provides regulatory agency information.
Conventions
Throughout the manual, the following conventions are used to describe user
interaction with the product:
prompt This style of type indicates screen display messages
Enter Press the key labeled Enter (or Delete, etc.)
Note
Supplementary information that can have an effect on
system performance.
Caution
Notification that a proscribed action has the potential
to adversely affect equipment operation, system
performance, or data integrity.
WARNING
Notification that a proscribed action will definitely
result in equipment damage, data loss, or personal
injury.
Manual No. 775051 v
Contents
Chapter 1
Introduction
Product Description ........................................................................... 1-1
Controller Features .................................................................... 1-2
Channel Capabilities .................................................................. 1-2
Controller Capabilities ................................................................ 1-2
Operating System Support ......................................................... 1-3
Standard Package Contents ............................................................. 1-4
Hardware .................................................................................... 1-4
Software ..................................................................................... 1-4
User-supplied Items .......................................................................... 1-5
Chapter 2
Installation
Before You Begin .............................................................................. 2-2
Safety Considerations ....................................................................... 2-3
Installation Checklist .......................................................................... 2-4
GET READY .............................................................................. 2-4
GET SET .................................................................................... 2-4
GO .............................................................................................. 2-4
Connectors, Jumpers and LEDs ........................................................ 2-5
PCI Hotplug ................................................................................ 2-5
Installation Process ........................................................................... 2-9
Installing the Controller .............................................................. 2-9
Preparing the SCSI Drives ....................................................... 2-11
SCSI Termination ..................................................................... 2-13
SCSI Cabling ................................................................................... 2-17
LVD Mode ................................................................................ 2-17
Single-ended Mode .................................................................. 2-17
Limitations on Mixing SCSI Drives .................................................. 2-18
Do Not Mix Narrow and Wide SCSI Drives .............................. 2-18
Mixing LVD with Single-ended Drives ...................................... 2-18
vi AcceleRAID 352 Installation Guide
Chapter 3
Controller Start-up
BIOS Options .....................................................................................3-1
Setting BIOS Options ................................................................. 3-2
BIOS Configuration Utility (RAID EzAssist) .......................................3-4
Operating System .............................................................................. 3-4
Operating System Device Drivers ......................................................3-4
Global Array Manager (GAM) Server ................................................ 3-4
Global Array Manager (GAM) Client ..................................................3-5
In Case of Problems .......................................................................... 3-5
Appendix A
BBM-Battery Backup Module
Product Description ...........................................................................A-1
Features .....................................................................................A-1
BBM Operation ..................................................................................A-2
Set-up – Enabling the Write-Back Cache ...................................A-2
Battery Backup Capacity ............................................................A-2
Maintenance ......................................................................................A-3
Removing the BBM ....................................................................A-3
BBM Functional Description ..............................................................A-3
Status Indication .........................................................................A-4
Battery and Charge Circuit .........................................................A-4
Disposition of Failed Batteries ....................................................A-4
BBM Specifications ............................................................................A-5
On-board Battery ........................................................................A-5
Battery Charge Life (Data Retention) .........................................A-5
Module Dimensions ....................................................................A-5
Environmental ............................................................................A-5
Warranty .....................................................................................A-5
Appendix B
AcceleRAID 352 Specifications
General Hardware Specifications ......................................................B-1
AcceleRAID 352 .........................................................................B-1
Appendix C
AcceleRAID 352 Error Messages
Start-up Error Messages ................................................................... C-1
Drive Check Error Messages ............................................................ C-1
Installation Abort ............................................................................... C-2
System Reboot or Power Down ........................................................ C-3
Manual No. 775051 vii
Appendix D
PCI Hot Plug
Introduction ........................................................................................D-1
Implementation ..................................................................................D-1
NetWare .....................................................................................D-1
Windows NT ...............................................................................D-3
Windows 2000 ............................................................................D-3
Windows 64 ................................................................................D-4
Appendix E
Enclosure Management
Introduction ........................................................................................E-1
SAF-TE ..............................................................................................E-1
SES ...................................................................................................E-2
Appendix F
Regulatory Information
Class B Compliance ..........................................................................F-1
Declaration of Conformity ..................................................................F-2
Declaration of Conformity ..................................................................F-3
Community of Europe ........................................................................ F-4
Underwriters Laboratories Statement and Warning ..........................F-5
Glossary
viii AcceleRAID 352 Installation Guide
Manual No. 775051 1-1
Chapter 1
Introduction
This chapter describes:
The AcceleRAID 352 controller
Standard package contents
User supplied items
Figure 1-1. AcceleRAID 352 Controller
Product Description
The Mylex AcceleRAID 352 controller is an Ultra 160 SCSI to a PCI dual
channel RAID controller with 64-bit, 33MHz PCI capability. The
AcceleRAID 352 supports two external Ultra 160 SCSI connectors, two
internal Ultra 160 SCSI connectors, and an optional battery backup module
(BBM). The AcceleRAID 352 controller provides the speed and
functionality required by high demand server platforms. AcceleRAID 352
achieves performance breakthroughs in PCI technology, eliminates storage
bottlenecks and delivers scalable performance. Enclosure management and
PCI Hot Plug are standard features.
Product Description
1-2 AcceleRAID 352 Installation Guide
Controller Features
Features of the AcceleRAID 352 controller include:
One Q-Logic ISP 12160A chip to support two Ultra 160 SCSI LVD
channels
Intel i960RN at 100MHz RISC processor
BBM (Battery Backup Module), optional
32MB, 64MB, or 128MB ECC cache DIMM module
PCI 2.1 and 2.2 compliant (PCI 2.2 required to use hotplug feature)
1MB, 8-bit flash EEPROM for BIOS and code
Built-in configuration utilities (in BIOS)
Write-through and write-back cache support.
PCI Hotplug capability allows the AcceleRAID 352 to be swapped
with a replacement without powering down the system.
Caution
Be sure the motherboard you are using supports
PCI Hotplug before attempting to use this feature,
or serious damage to the controller and/or the
motherboard could result. (You must be PCI 2.2
compliant if using PCI Hot Plug.)
Channel Capabilities
15 Ultra 160 SCSI devices per channel
Controller Capabilities
16 physical drives per drive group (array)
Number of drive groups is limited by number of physical drives on the
controller
32 total logical drives per controller
Supports RAID levels 0, 1, 0+1, 3, 5, 10, 30, 50, and JBOD
Introduction
Manual No. 775051 1-3
Operating System Support
MS-DOS 5.x, 6.x, and above are supported using drivers that reside in the
AcceleRAID BIOS. Many other popular operating systems are supported
using software drivers in the Disk Array Controller Software Kit that is
included with the AcceleRAID 352 controller (see the PCI Disk Array
Controller Drivers Installation Guide and User Manual).
Standard Package Contents
1-4 AcceleRAID 352 Installation Guide
Standard Package Contents
The following items are supplied with the standard shipping package:
Hardware
AcceleRAID 352 Disk Array Controller with documentation included
on the CD-ROM and a printed Quick Installation Guide.
Standard DIMM Memory Module: 32MB, 64MB, or 128MB with an
optional battery backup (BBM) pre-installed, OR
Standard DIMM Module only: 32MB, 64MB, or 128MB
Software
RAID EzAssist disk array controller configuration utility with
documentation on CD-ROM and a printed Quick Configuration Guide.
Software Kit Driver with documentation on CD-ROM and a printed
PCI Drivers Installation guide
Global Array Manager (GAM) with documentation on CD-ROM
Figure 1-2. Standard Package Contents
Introduction
Manual No. 775051 1-5
User-supplied Items
The following user-supplied items are required to perform this installation:
IBM-PC compatible host system with PCI slot (PCI 2.1 and 2.2
compliant; you must be PCI 2.2 compliant to use PCI Hot Plug)
Network operating system software (as required)
SCSI cables to connect the controller and disk arrays
Static grounding strap or electrostatic discharge (ESD) safe work area
Disk array enclosure (or equivalent) with SCSI disk drives
User-supplied Items
1-6 AcceleRAID 352 Installation Guide
Manual No. 775051 2-1
Chapter 2
Installation
This chapter describes:
Before you begin
Safety considerations
Installation checklist
Connectors, Jumpers, LEDs
Controller installation
SCSI cabling and termination
SCSI IDs
Limitations on mixing SCSI drive types
Mylex disk array controllers are designed to work in a variety of SCSI RAID
application environments. Certain configuration steps need to be performed
prior to installing the controller into a RAID environment. Each of the steps
described in this chapter are part of the installation process.
Before You Begin
2-2 AcceleRAID 352 Installation Guide
Before You Begin
Installing the AcceleRAID 352 Dual Channel RAID controller is no more
difficult than installing any 32-bit or 64-bit PCI adapter. The AcceleRAID
352 dual channel controller connects into any PCI slot (PCI 2.1 or 2.2
compliant) on the motherboard. Follow these steps and the installation
procedures in this chapter.
WARNING
Working with the system covers off and power
applied to the system can result in shock and
serious injury.
This controller is furnished with a nonvolatile
RAM (NVRAM) chip that uses a sealed lithium
battery/crystal module. Replace the module only
with the same or equivalent type recommended by
the manufacturer.
Dispose of the used battery/crystal module
according to the manufacturer’s instructions.
Never incinerate a battery as it could explode and
cause serious injury.
1. Power off the system and disconnect the power cables before starting
the installation. Refer to the instructions provided in your system
documentation. Do not disconnect cables or power cords while system
power is on.
2. Read all of the instructions in this chapter completely before proceed-
ing. Follow the Notes, Cautions, and Warnings described in this manual
and marked on the equipment.
3. Follow electrostatic discharge (ESD) safe procedures. Use a grounded
wrist strap or ESD safe footwear, and work in an ESD safe area.
4. Perform a safety check of the installation before powering on the
system.
Make sure that the cabling Pin 1 location is correct and that all
cables are firmly seated in the connectors.
Make sure all SCSI conventions (cable type, cable length,
termination, etc.) are correct, see Table 2-5.
Installation
Manual No. 775051 2-3
Safety Considerations
Be sure to observe the following precautions before beginning the controller
installation procedure:
Caution
Anti-static handling procedures are required. Leave
the controller in its anti-static bag until it is time to
plug the controller into the PCI slot. The use of a
grounded wrist strap and other ESD protective
measures are highly recommended.
WARNING
Disconnect the system from the electrical wall
outlet before opening the system cabinet. Working
with the system covers off and power applied to the
system can result in shock and serious injury.
Installation Checklist
2-4 AcceleRAID 352 Installation Guide
Installation Checklist
GET READY
Note
It is recommended that you wear a grounded wrist
strap when working with hardware installation
procedures.
1. ____ Power off your computer system.
2. ____ Decide which available PCI slot will be used.
3. ____ Remove the plate from the I/O access port to the PCI slot.
4. ____ Remove the AcceleRAID 352 controller from the anti-static bag.
GET SET
5. ____ Plug the AcceleRAID 352 controller into a standard PCI slot
(PCI 2.1 or 2.2 compliant--if using hotplug feature, must be 2.2).
6. ____ Tighten the AcceleRAID 352 controller into the mounting
bracket.
7. ____ Connect the SCSI cable(s) from your drive(s) and/or device(s) to
the desired SCSI channel.
8. ____ Check SCSI termination for internal and/or external devices.
9. ____ Check disk drives. Be sure termination is set to the disabled
position on any disk drive(s) that will not be terminated. For more
information, see the documentation that accompanied the disk
drives.
10. ____ Set SCSI ID on the disk drive(s).
11. ____ Enable termination power on disk drive(s).
12. ____ Safety check the installation.
Note
Review Figure 2-1 and Table 2-5 to get familiar with
the layout of the AcceleRAID 352 controller and the
Connectors, Jumpers, and LED descriptions.
GO
13. ____ Go to Chapter 3, Controller Start-up.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92

Mylex AcceleRAIDTM 352 PCI to Ultra 160 SCSI RAID Controller AcceleRAID 352 User manual

Category
Networking
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI