Bull Escala - Ultra SCSI PCI RAID Adapter Reference guide

Category
Disk arrays
Type
Reference guide
Bull
Ultra SCSI PCI RAID Adapter
Reference Guide
86 A1 91KX 00
ORDER REFERENCE
Bull
Ultra SCSI PCI RAID Adapter
Reference Guide
Hardware
November 1999
BULL ELECTRONICS ANGERS
CEDOC
34 Rue du Nid de Pie – BP 428
49004 ANGERS CEDEX 01
FRANCE
86 A1 91KX 00
ORDER REFERENCE
The following copyright notice protects this book under the Copyright laws of the United States of America
and other countries which prohibit such actions as, but not limited to, copying, distributing, modifying, and
making derivative works.
Copyright
Bull S.A. 1992, 1999
Printed in France
Suggestions and criticisms concerning the form, content, and presentation of
this book are invited. A form is provided at the end of this book for this purpose.
To order additional copies of this book or other Bull Technical Publications, you
are invited to use the Ordering Form also provided at the end of this book.
Trademarks and Acknowledgements
We acknowledge the right of proprietors of trademarks mentioned in this book.
AIX
R
is a registered trademark of International Business Machines Corporation, and is being used under
licence.
UNIX is a registered trademark in the United States of America and other countries licensed exclusively through
the Open Group.
Year 2000
The product documented in this manual is Year 2000 Ready.
The information in this document is subject to change without notice. Groupe Bull will not be liable for errors
contained herein, or for incidental or consequential damages in connection with the use of this material.
Preface
v
Contents
About This Book ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Who Should Use This Book ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
How to Use This Book ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISO 9000 x. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Related Publications x. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ordering Publications x. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 1. Ultra SCSI PCI RAID Adapter Overview 1-1. . . . . . . . . . . . . . . . . . .
Disk Arrays 1-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAID Levels 1-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAID Level 0 1-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAID Level 1 1-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RAID Level 5 1-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ultra SCSI PCI RAID Adapter Features 1-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ultra SCSI PCI RAID Adapter 1-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disk Array 1-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI Disk Drives 1-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCI SCSI Disk Array Manager 1-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disk Array Overview 1-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disk Array Parameters 1-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Identify Drives and Disk Arrays 1-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disk Array ODM Information 1-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 2. Installing the Ultra SCSI PCI RAID Adapter Software 2-1. . . . . .
Installing an Ultra SCSI PCI RAID Adapter on AIX Version 4 2-1. . . . . . . . . . . . .
Prerequisite 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Procedure 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing a Ultra SCSI PCI RAID Adapter Software Update 2-4. . . . . . . . . . . . . .
Procedure 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying the Ultra SCSI PCI RAID Adapter Software Installation 2-5. . . . . . . . . .
Chapter 3. Managing the Ultra SCSI PCI RAID Adapter 3-1. . . . . . . . . . . . . . .
Procedure 3-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Guide
vi
Starting the PCI SCSI Disk Array Manager 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Disk Array 3-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modifying and Displaying Drive Status 3-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
View the Current Disk Array Status 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Add a Spare Drive 3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Delete a Spare or Failed Drive 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fail a Drive 3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing a Disk Array 3-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reviving a Failed Drive 3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assigning Hot Spare Drives 3-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transitioning a Hot Spare Drive to a Spare Drive 3-13. . . . . . . . . . . . . . . . . . . . . . .
Performing a Consistency Check on a Disk Array 3-13. . . . . . . . . . . . . . . . . . . . . . .
Reconstructing a Failed Drive 3-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Change/Show PCI SCSI Disk Array Parameters 3-15. . . . . . . . . . . . . . . . . . . . . . . .
Configuration Synchronization 3-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clearing a Configuration 3-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adapter Replacement 3-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adding Disk Arrays to the AIX Operating System 3-18. . . . . . . . . . . . . . . . . . . . . . .
Deleting Disk Arrays from the Operating System 3-20. . . . . . . . . . . . . . . . . . . . . . .
Chapter 4. Ultra SCSI PCI RAID Adapter Problem Determination and
Recovery 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drive Failures and Disk Arrays 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drive Status 4-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disk Array Failures 4-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reconstructing Redundant Disk Arrays after Drive Failure 4-5. . . . . . . . . . . . . . .
The Reconstruction Rate – Low, Medium, High 4-7. . . . . . . . . . . . . . . . . . . . . .
Change Reconstruction Rate Parameters 4-7. . . . . . . . . . . . . . . . . . . . . . . . . . .
Checking Consistency (Check and Repair Array Parity) 4-8. . . . . . . . . . . . . . . . .
Perform Check Consistency 4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Restoring and Recovering Disk Arrays 4-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Restoring a Disk Array 4-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the Ultra SCSI PCI RAID Adapter 4-17. . . . . . . . . . . . . . . . . . . . . . . . .
Detecting and Resolving Array Configuration Conflicts 4-17. . . . . . . . . . . . . . . .
Resolving Disk Array Configuration Conflicts 4-20. . . . . . . . . . . . . . . . . . . . . . . .
Resolving Common Problems 4-21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Messages and Error Log Templates 4-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temporary RAID Adapter Error 4-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Permanent RAID Adapter Error 4-24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface
vii
Temporary Array SCSI Bus Error 4-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temporary Physical Volume Error 4-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Permanent Physical Volume Error 4-27. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Array Configuration Error 4-28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Array Component Failure 4-29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temporary Unknown Software Failure 4-30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recovered RAID Adapter Error 4-31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alertable Messages 4-32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Index X-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Guide
viii
Preface
ix
About This Book
This manual provides information for the Ultra SCSI PCI RAID Adapter. Topics
covered include an introduction to the adapter, installing, and information about
performing tasks necessary to manage an adapter and determine problems.
Who Should Use This Book
This book is intended for system administrators and system programmers.
These are persons responsible for installing and maintaining the system. To use
this book, you must already be familiar with AIX commands, utilities, and
procedures.
How to Use This Book
The following overview briefly describes the contents of each chapter:
Chapter 1, “Ultra SCSI PCI RAID Adapter Overview,” presents adapter
concepts and features of the PCI RAID Adapter.
Chapter 2, “Installing the Ultra SCSI PCI RAID Adapter,” provides
procedures for the installation of the PCI RAID Adapter software.
Chapter 3, “Managing the Ultra SCSI PCI RAID Adapter,” provides
information and procedures for changing subsystem characteristics, creating,
deleting, and managing disk arrays.
Chapter 4, “Ultra SCSI PCI RAID Adapter Problem Determination and
Recovery,” provides information to assist you in determining and recovering
from error conditions.
Highlighting
The following highlighting conventions are used in this book:
Bold Identifies commands, subroutines, keywords, files, structures,
directories, and other items whose names are predefined by the
system. Also identifies graphical objects such as buttons,
labels, and icons that the user selects.
Italics Identifies parameters whose actual names or values are to be
supplied by the user.
Reference Guide
x
Monospace Identifies examples of specific data values, examples of text
similar to what you might see displayed, examples of portions
of program code similar to what you might write as a
programmer, messages from the system, or information you
should actually type.
ISO 9000
ISO 9000 registered quality systems were used in the development and
manufacturing of this product.
Related Publications
The following books contain information about or related to the Ultra SCSI PCI
RAID Adapter:
Diagnostic Information for Multiple Bus System, Order Number SA38-0509.
The RAID book, A Source Book for Disk Array Technology, Edition 4.
Published by: The RAID Advisory Board, St. Peter, MN, 1994
AIX Version 4 System Management Guide: Operating System and Devices,
Order Number SC23-2525
Ordering Publications
You can order publications from your sales representative or from your point of
sale.
If you received a printed copy of AIX and Related Products Documentation
Overview with your system, use that book for information on related
publications and for instructions on ordering them.
To order additional copies of this book, use order number SC23-4302.
PCI RAID Adapter Overview
1-1
Chapter 1. Ultra SCSI PCI RAID Adapter
Overview
Redundant Array of Inexpensive Disks (RAID) technology offers the user these
primary features:
Larger disk capacity
Immediate availability/recovery of data
Redundancy of data at a user-selected level
Enhanced Performance
Using RAID technology, data is stored across a series of disk drives known as a
disk array. Depending on the RAID level selected, this storage technique
provides the data redundancy required for a secure system without depleting
memory, and may have the further advantage of faster retrieval through multiple
channel access. Also, in the event of hardware failure, a single disk drive can
usually be replaced without interrupting normal system operation.
Disk Arrays
Disk arrays are groups of disk drives that work together with a specialized array
controller to achieve higher data-transfer and input and output (I/O) rates than
those provided by single large drives. The array controller keeps track of how
the data is distributed across the drives.
Redundant disk arrays can also provide data redundancy, so that no data is lost
if a single drive in the array fails. Two methods of writing data to the disk drives
are used in a RAID subsystem:
striping Data for a given file may be written in stripe units to different
drives in the array, rather than being written to a single drive. By
using multiple drives, the array can provide higher data-transfer
rates and higher I/O rates when compared to a single large
drive.
mirroring Data that is simultaneously written to two separate disks within
the same array.
Reference Guide
1-2
The method used for writing the data to an array is determined by the RAID
level defined for that array and the number of drives used. “RAID Levels” on
page 1-4 discusses the various RAID levels and their function in detail.
PCI RAID Adapter Overview
1-3
The Disk Arrays and Channels figure illustrates the terms used in describing
disk arrays.
Disk Array Controller
0 1 2
Array
Subsystem
RAID 5
disk
array
Channel #
(0–2)
Disk Arrays and Channels
id 0
online
id 0
online
id 0
online
id 1
spare
id 1
online
id 1
online
id 2
online
id 2
online
id 2
online
id 3
online
id 3
hot
spare
id 3
online
RAID 0
disk
array
RAID 1
disk
array
Reference Guide
1-4
Each disk array is viewed as a single logical device with a unique disk name
and location code.
Each disk array has its own array parameters (for example, RAID level and
capacity). A disk array is treated as a single disk drive by the operating system.
There are no special requirements for using it. AIX commands and utilities work
on disk arrays just as they would with single non-RAID drives.
For example, after you configure a disk array with the PCI SCSI Disk Array
Manager (PDAM), you can use AIX commands to make the disk array available
to the system by adding it to a volume group, creating a file system on it, and so
on. Raw I/O is also supported on disk arrays. When adding a disk array to your
system, treat it in the same way you would treat a single disk drive.
Note: Diagnostic open and SCSI passthrough are not supported on disk
arrays.
RAID Levels
Each RAID level reflects a different design architecture in terms of error
recovery available when a part of the system fails. Depending on the RAID level
chosen, (with the exception of RAID level 0), if a single drive fails within an
array, the data from that disk can be reconstructed from the data stored on
other hard drives within the array. This data can be reconstructed or “put back
into service” with little or no impact to the users and programs that are using the
the system at the time of the failure.
The levels of RAID supported varies between different hardware and software
platforms, but the most common levels supported are 0,1, 3, and 5.
Note: The Ultra SCSI PCI RAID Adapter supports RAID levels 0, 1, and 5.
Each of the levels supported by the Ultra SCSI PCI RAID Adapter uses a
different method of writing data to provide specific benefits with each method.
For example, RAID level 5 creates array parity information in order to
reconstruct data lost because of a drive failure in the array. RAID level 1
maintains a duplicate copy of the data in order to reconstruct data lost because
of drive failure. RAID level 0 does not provide data redundancy, but it provides a
potentially higher I/O rate. The following information provides details about
RAID levels 0, 1, and 5.
PCI RAID Adapter Overview
1-5
RAID Level 0
Attention: It is critical that you regularly back up data on a RAID level 0 array.
This is the only way to recover data in the event of a disk drive failure. The
ability to recover data on the array depends on the backup procedures you have
established.
RAID level 0 writes data across the drives in the array, one stripe unit at a time.
In this example, a stripe unit is defined as 32 blocks of 512 bytes each (16K
stripe unit size), as shown in the RAID Level 0 figure. For a 128K write, blocks 0
through 31 are written to drive 1, blocks 32 through 47 are written to drive 2,
blocks 48 through 63 are written to drive 3 and so on as each drive has a single
stripe unit written to it. Finally, blocks 224 through 255 are written to drive 3 to
complete the write operation.
Disk Array Controller
SCSI SCSI SCSI
Disk
Drive 1
Disk
Drive 2
Disk
Drive 3
RAID Level 0
stripe units
2, 5, 8
blocks:
32–47,
96–127,
192–223
stripe units
1, 4, 7
blocks:
0–31,
64–95,
160–191
stripe units
3, 6, 9
blocks:
48–63,
128–159,
224–255
Reference Guide
1-6
The host system treats a RAID level 0 array like a standard disk drive. RAID
level 0 errors are reported in the same way as normal drive errors, and the
recovery procedures are the same as those used on a standard disk drive. For
example, if a drive fails, the array controller returns the same errors that occur
during a read or write retry failure. All data on the array may be lost. However,
unlike other RAID levels, the array controller never marks a RAID level 0 array
as degraded as the result of a drive failure. If a physical drive fails in a RAID 0
disk array, the disk array is marked as dead.
RAID level 0 offers a higher potential I/O rate, but is a non-redundant
configuration. That is, there is no array parity information generated for the
purpose of reconstructing data in the event of a drive failure. Therefore, there is
no error recovery beyond what is normally provided on a single drive. All data in
the array must be backed up regularly to protect against data loss.
RAID Level 1
Attention: Though a RAID level 1 array has data redundancy, you should
regularly back up data on the array. This is the only way to recover data in an
event such as accidental file deletion or disaster recovery. You can continue to
operate the array in degraded mode until you replace the drive. However, you
should replace the drive as soon as possible. If you cannot replace the drive
immediately, back up your data file by file to prevent potential data loss.
RAID level 1 transparently mirrors data by duplicating data stripes across
drives. When data is written to a drive, it is also written to a mirrored stripe.
Traditionally, RAID level 1 has been used for critical fault-tolerant transaction
processing. Mirrored data provides high reliability. When a small block size is
used, mirrored data also provides a high I/O rate. However, RAID level 1 is a
more costly RAID solution because it requires a mirrored data stripe for every
physical drive in the array.
RAID level 1 writes data across the drives in the array, one stripe unit at a time.
In this example, a stripe unit is defined as 64 blocks of 512 bytes each (32K
stripe unit size) as shown in the RAID Level 1 figure. For a 32K write, blocks 0
PCI RAID Adapter Overview
1-7
through 63 are written to drive 1 and the mirrored data blocks 0-63 are written
to the mirrored data drive .
Disk Array Controller
SCSI SCSI SCSI
Disk
Drive 1
data
SPARE
mirrored
stripe unit
1
blocks
0–63
stripe unit
1
blocks
0–63
RAID Level 1
Disk
Drive 2
mirror
If a single drive fails in a RAID level 1 array, you can continue to use the array.
A RAID level 1 array operating with a single failed drive is said to be operating
in degraded mode. Whenever you read or write to a disk array in degraded
mode, the array controller retrieves the failed drive’s data from its mirrored
drive. Although you can continue to operate the RAID level 1 array with a failed
drive, you should replace the drive and restore the array as soon as possible.
Using the Perform Consistency Check menu allows the array controller to
compare the data drive and mirror to verify consistency after an abnormal
system shutdown. See “Performing a Consistency Check on a Disk Array” on
page 3-13.
Reference Guide
1-8
RAID Level 5
Attention: Even though a RAID level 5 array maintains parity information, it is
still important that you regularly back up data on the array. This is the only way
to recover data, for example, in the event of accidental file deletion or disaster
recovery. You can continue to operate the array in a degraded mode until you
can replace the drive. You should replace the drive as soon as possible. If you
cannot replace the drive almost immediately, you should back up your data file
by file to prevent potential data loss.
RAID level 5 stripes data across all drives in the array one stripe unit at a time
(a stripe unit can contain multiple blocks). RAID level 5 also writes array parity
data. The parity data is spread across all the drives.
PCI RAID Adapter Overview
1-9
In the RAID Level 5 example figure, a stripe unit is defined as 64 blocks of 512
bytes each (32K stripe unit size).
Disk Array Controller
SCSI SCSI SCSI
Disk
Drive 1
Disk
Drive 2
Disk
Drive 3
Parity
Parity
Parity
stripe unit
1
stripe unit
2
stripe unit
3
stripe unit
4
stripe unit
5
RAID Level 5
stripe unit
6
Reference Guide
1-10
Stripes are written as follows:
Stripe 1 is written in the first position to drive 2
Stripe 2 is written to drive 3
Parity data for the data in stripes 1 and 2 are written to drive 1
If a drive fails in a RAID level 5 array, you can continue to use the array
normally. A RAID level 5 array operating with a single failed drive is said to be
operating in degraded mode. Whenever data is read from a degraded disk
array, the array controller recalculates the data on the failed drive by using data
and parity blocks on the operational drives.
For example, to recalculate data in data stripe unit 2 in the RAID level 5 figure
(the first position on drive 3), the array controller would use the parity
information from drive 1 and the data from drive 2 (data stripe unit 1) to
reconstruct the data. This process is repeated to reconstruct each block of the
failed drive, as needed, so you can continue to operate the RAID level 5 array.
The Perform Consistency Check menu allows the array controller to check the
integrity of the array parity. If the array subsystem has an abnormal system
shutdown, you may check and repair array parity/mirror on the affected disk
array(s). See “Performing a Consistency Check on a Disk Array” on page 3-13
for more information.
Ultra SCSI PCI RAID Adapter Features
The major components of the Ultra SCSI subsystem are:
Ultra SCSI PCI RAID Adapter. The SCSI controllers and RAID logic are
located on the adapter.
Disk Array. A collection of one or more SCSI disk drives.
SCSI Disk Drives
PCI SCSI Disk Array Manager (PDAM). (SMIT and command line interface)
AIX device drivers
The components of the RAID subsystem combine to provide an advanced
storage technique designed to secure online information while speeding file
access through multiple, independent transactions.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101

Bull Escala - Ultra SCSI PCI RAID Adapter Reference guide

Category
Disk arrays
Type
Reference guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI