Vemer Chronos RF Bianco User manual

Category
Thermostats
Type
User manual

Vemer Chronos RF Bianco is a radiofrequency digital chronothermostat that allows you to regulate the ambient temperature both in heating and cooling modes. It can be controlled via a remote actuator through a radiofrequency signal, allowing you to manage your heating and cooling system wirelessly. The wide touch screen display with backlighting allows for clear viewing even in the dark. The chronothermostat has a weekly programming feature with 3 different settable temperatures, so you can customize your heating and cooling schedule to suit your needs.

Vemer Chronos RF Bianco is a radiofrequency digital chronothermostat that allows you to regulate the ambient temperature both in heating and cooling modes. It can be controlled via a remote actuator through a radiofrequency signal, allowing you to manage your heating and cooling system wirelessly. The wide touch screen display with backlighting allows for clear viewing even in the dark. The chronothermostat has a weekly programming feature with 3 different settable temperatures, so you can customize your heating and cooling schedule to suit your needs.

Cronotermostato
Digitale a radiofrequenza
CHRONOS RF
Manuale d’Uso
User Manual
RADIOFREQUENCY DIGITAL
CHRONOTHERMOSTAT
PDF
English
- 1 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Q Dimensions Page 3
Q Connection diagram Page 3
Q Safety warnings Page 4
Q Technical specifications Page 5
Q Display and keyboard Page 6
Q Installation Page 7
Q Programming menu Page 11
- Time and date modification Page 11
- Programs modification Page 11
- Temperatures T1, T2, T3 modification Page 13
- Timing setting Page 15
- Advanced functions menu Page 16
- Radiofrequency menu Pagina 19
Q Manual operation Page 20
Q Off operation Page 21
Q Minimum and maximum value Page 22
Q Summer time change Page 22
Q Regulation type Page 24
Q Timings: what they are Page 26
Q Instrument reset Page 28
Q Battery replacement Page 28
Q Reference standards Page 29
Q Winter preset programs Page 30
Q Summer preset programs Page 31
Q Default values Page 32
Index
English
- 2 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Radiofrequency digital chronothermostat CHRONOS RF
Touch screen display of capacitive
type (sensible to the fingers’ touch)
Summer and winter operating mode
Models available in white and black
colours
7 programs available for the heating
mode
7 programs available for cooling
mode
Integrated radiofrequency module
Weekly programming with 3
different settable temperatures
Wall-mounting or
to coverage of box 503
C
HR
O
N
OS
RF Radiofreq
u
English
- 3 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
DIMENSIONS
CONNECTION DIAGRAM
10.5 15.5
For more detailed information about the instruments configuration see
chapter “Installation” page. 7 and “Radiofrequency menu” on page 19.
Load activation occurs through the remote actuator controlled by the chronothermostat
by means of a radiofrequency signal.
Chronos RF LoadRemote actuator
1 or more channels
English
- 4 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Q During product installation and operation it is necessary to observe the
following instructions:
1) The instrument must be installed by a qualified person, in strict compliance
with the connection diagrams.
2) Do not power the instrument if any part of it is damaged.
3) The instrument must be installed and activated in compliance with current
electric system standards.
4) Do not use the instrument for purposes different from the one specified.
5) In case of malfunction do not perform repairs and contact immediately the
technical support.
6) The instrument can be used in environments with category of measurement III
and pollution degree 2.
Code Model Description
VE484200 Chronos RF Bianco Radiofrequency touch screen chronothermostat white
VE485900 Chronos RF Nero Radiofrequency touch screen chronothermostat black
SAFETY WARNINGS
Chronos RF is a weekly touch screen electronic chronothermostat to regulate the
ambient temperature both in heating and cooling to control a remote actuator through
a radiofrequency signal.
Powered by two batteries of AAA type, Chronos RF doesn’t need any wiring. This
allows to install the thermostat anywhere inside your room, without any intervention
of masonry.
The wide touch screen display with backlighting on by pressing a key allows a clear
viewing even in the dark.
English
- 5 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
TECHNICAL SPECIFICATIONS
Power supply:
– 2 alkaline batteries 1.5 V (AAA type)
battery life: 1 year
battery charge level indication
charge reserve (for battery replacement): 1 minute
• Wall mounting or to coverage three-module in built box
Temperature regulation:
On/off with hysteresis setting between 0,1 °C and 1 °C
Proportional with settable band and period
Summer (cooling) / winter (heating) operating mode
• Weekly programming (7 programs available for each operating mode)
Daily resolution: 1 hour (possibility to set delay activation of 15, 30, 45 minutes
independent for each hour)
• 5 settable temperatures:
T1, T2, T3 in automatic operation
Tm in manual operation
Toff in off mode (antifreeze)
Measured temperature display: 0 ÷ 50 °C
Measurement precision: ±0.5 °C: ±0.5 °C
• Measured temperature resolution: 0.1 °C
• Setpoint range: 2 ÷ 50 °C
Clock precision: ±1 second/day
• Summer/winter time automatic change (excludable)
• Operating temperature: 0 ÷ +50 °C
Storage temperature: -10 ÷ +65 °C
Operating humidity: 20÷90% non condensing
• Touch screen display with backlighting on with a key touch.
Password protected lock keypad
• Communication with the actuator through a radiofrequency signal 433.92 MHz
Maximum power of the radiofrequency trasmitted in the frequency bands where the
radio equipment operates: 10 dBm max
Maximum distance between thermostat and actuator: 50 m in free field
Protection degree: IP40
• Insulation: reinforced among accessible parts (frontal) and all other terminals
English
- 6 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Day of the week (DAY 1 = Monday)
Programming menu:
: date/time and summer time setting
: programs change mode (for automatic operating)
: temperatures setting T1, T2. T3
: timing menu
: advanced programming menu
: not used
: radiofrequency transmission menu
Time and minutes
Load activation in summer mode/ cooling
Manual operation activation
Load activation in winter mode/heating
Measured environment temperature
Program on graphic for the current date (in automatic operation)
Off operation
Depleted battery indication
Keyboard (the keys are active only if the instrument is correctly installed on
wall-mounted base)
DISPLAY AND KEYBOARD
English
- 7 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Q
Keyboard
The keys carry out different functions on the basis of the instrument status and they
will be described step by step in this user manual.
Multipurpose keys are not built into the instrument, that is to say contemporary
pressures of 2 or more keys.
There are two types of pressure:
- brief pressures,
- long pressures, with duration higher than 3 seconds.
During the press of a button, the display is blue.
Attention: press the keys with your fingers, do not use sharp objects!
Attention: the keys are active only if the instrument is hooked to the base
Q Cleaning the display
To clean the display use a soft, lint-free cloth, without using excess force.
INSTALLATION
Association between Chronos RF and remote actuator
Because the Chronos RF and a remote actuator can communicate correctly, it’s
necessary to perform a procedure called “self-learning”, during which the remote
actuator recognizes and stores the identity of Chronos RF.
To perform the self-learning proceed as follows:
1. Activate the channel configuration of the remote actuator (see the instructions).
The actuator remains in configuration mode for a pre-set time, within which it must
receive the configuration string from Chronos RF.
2. Insert the batteries in the Chronos RF, respecting the polarity indicated on the
instrument (to access the batteries compartment it’s
necessary to unhook the thermostat from the base by
pressing the tab at the bottom of the instrument).
After about 3 seconds the Chronos RF initiates the
configuration procedure (indicated by RQI on the
display) followed by a short test procedure (indicated
by 7HVW on the display) where Chronos RF sends the
sequence on-off-on-off to the actuator.
English
- 8 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
3. Upon receipt of the configuration string, the remote actuator is configured and
resumes the normal operation while the Chronos RF requires date and time
insertion ( the programming keys will be active only after you have hooked the
thermostat at the base)
Note: to associate a second remote actuator, activate the configuration of
the actuator channel and, while this last is in configuration mode, remove
the thermostat from the base and re-put it (the cronothermostat starts the
configuration procedure to which follows the testing procedure).
• Indications for placement
The Chronos RF is designed for wall-mounting installation or to cover the 503 box
1
2
1
Fix the base on the wall using the screws
supplied.
Attach the chronothermostat to the base,
at first mating teeth first placed on the
upper side.
Place the chronothermostat at a height at about 1.5 m above the floor, away from
direct sunlight, away from doors, windows, heat sources, locations with excess or total
lack of aeration.
The actuator is usually placed near the boiler to pilot.
Attention: the maximum distance between Chronos RF and remote actuator is about
50 m in free field. This value is reduced if there are obstacles in the middle (for
example, reinforced concrete walls).
English
- 9 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
• Clock setting
Once the instrument is mains powered, set the clock (time and date insertion).
The parameters to enter are the following:
seconds (only synchronisation at value 00), minutes, hours, year, month, day.
Use the keys and to increase and decrease the values and the key to
confirm and to move to the next parameter.
Seconds synchronisation
Minutes setting
Time setting
Year setting
Month setting
Day setting
Once all values are set, press for a long time (3 seconds) the key to exit the menu
of the clock synchronisation.
English
- 10 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
At this point the chronothermostat
will begin to operate with the set
default parameters (see page
32) displaying the day of the
week, the time, the environment
temperature and the graphic of
the program on.
When Chronos RF sends an on
or off command to the remote
actuator, icon (field 2) lights
for a moment.
DAY TEMPERATURE
HOUR
Attention:
To operate correctly the chronothermostat requires the time and date
insertion.
If once mains powered, no value is
set within about 40 seconds, the
chronothermostat begins to operate in
off mode, displayed with the symbol
. The time lack is displayed with
flashing dashes ( _ _:_ _ ).
The chronothermostat remains in off operation condition until when the hour
is not inserted, ensuring in this way the saving of the antifreeze temperature
(6 °C).
In this condition, the pressure of any key reactivates the menu of date/time
insertion for other 30 seconds about.
PROGRAM
GRAPHIC
English
- 11 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
PROGRAMMING MENU
With this menu it’s possible to modify the
following operating parameters:
- Date and time
- Automatic operation programs
- Automatic operation temperatures
- Timings
- Advanced functions.
- Radiofrequency menu
Time and date modification
To modify the hour and the date set:
1. From normal operating display, press for a long time the key until the symbol
starts flashing on field (2)
2. Press the key to access parameters modification. The seconds field starts
flashing. Parameters sequence to set:
seconds* -> minutes -> hours -> month ->day
3. Use the keys and to modify the values and the key to confirm moving to
the next parameter.
(*) for seconds it’s possible only the synchronisatin at value 00
4. Once all parameters are set, to exit and to go back to the programming menu, press
a short time the key .
To exit and to go back to the normal operating (automatic, manual) press for a long
time or wait for the time-out expiration (40 seconds about).
Inside this menu it’ s also possible to modify the parameters for winter/
summer time change. The procedure is described in a detailed way in the
chapter “Summer time change” on page 22.
Programs modification
This menu allows to modify the programmings of the automatic operation.
In default status the instrument is configured to perform the program P1 from Monday
3s
Inside this menu it’ s also
p
ossible to modif
y
the
p
arameters for winter
/
summer t
i
me c
h
ange.
Th
e proce
d
ure
i
s
d
escr
ib
e
d
i
n a
d
eta
il
e
d
way
i
n t
h
e
c
hapter “Summer time chan
g
e” on pa
g
e 22
.
English
- 12 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
to Friday and P2 on Saturday and on Sunday (the programs profile is described at the
end of this manual on page 30-31).
If this programming doesn’t satisfy the user needs it’ s possible to change it.
To modify the programming:
1. From the normal operation display, press for a long time the key until the
symbol starts flashing on field (2)
2. Press for a short time the key until the symbol flashes and press the key
to access the parameters modification.
3. The programs page is displayed:
the first day of the week (DAY 1) flashing,
the current program (for example P1) of the
current operating mode ( o ) and the
corresponding profile of the program.
3.1.
If the set program is good, move to the
next day with the keys and .
3.2. If the set program is not good, press
the key .
The set program flashes: choose a
different program among the 7 available
programs pressing the keys and .
3.2.1. If no program exactly satisfies the
user’s needs, choose any program
which best meet them and
press the key to access the
modification of the program profile.
On field (3)  appears while
on field (7) flashes the temperature
level (T1, T2 o T3) set for that
specific time (00:00).
English
- 13 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Use the keys and to change
the temperature level and the key
to move to the next hour. Set like
this the desired level temperature
for each hour of the day.
3.2.1.1. For each hour it’ s possible to
delay the start of th regulation of
15’, 30’ or 45’
After setting the temperature
as described above, press for
a long time the key to set
a delay.
The minutes field flashes (field
3): set with the keys and
the delay and press the key
to move to the next hour.
4. When the program satisfies the user’s needs, go back to the days pressing twice
the key and repeat for the other days of the week the operations.
When all modifications have been performed, exit the programming menu pressing
for a long time the key .
Temperatures T1, T2, T3 modification
To modify the 3 temperatures of automatic operation:
1. From the normal operation display, press for
a long time the key until the symbol
starts flashing on field (2)
2. Press for a short time the key until the
symbol flashes. Press the key to
access the parameters modification.
3s
English
- 14 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
3. The value of the flashing T1 temperature is
displayed. Modify the value with the keys
and and press the key to move
to the modification of T2.
4. The value of the flashing T2 temperature is
displayed. Modify the value with the keys
and and press the key to move
to the modification ofi T3.
5. The value of the flashing T3 temperature is
displayed. Modify the value with the keys
and and press the key to go
back to the page of T1 temperature.
6. Once all parameters are set, to exit and to
go back to the programming menu, press
for a short time the key .
To exit and to go back to the normal
operation press for a long time the key
or wait for the time-out expiration (40
seconds about).
Attention: the values of set temperatures
must respect the condition:
T1 ≤ T2 ≤ T3.
In cooling mode T1 is not
settable and equals off system.
English
- 15 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Timing setting
This menu allows the setting of a timing on the current operating mode, expressed in
hours and days.
For further information about timings, see the chapter “Timings: what they
are” on page 26).
To set a timing:
1. From the normal operation display, press for a long time the key until the
symbol starts flashing on field (2)
2. Press for a short time the key until the
symbol flashes and press the key to
access the parameters modification.
3. The value of the timing currently set
flashes (00= no timing). Enter the timing
value (from 1 to 99) with the keys and
and press the key to move to the
measurement unit change (hours and days).
4. The measurement unit starts flahing (KRXU
or GD\). Press the keys and to
choose a timing in hours (KRXU) or days
(GD\).
For
f
urther in
f
ormation about timin
g
s, see the chapter “Timin
g
s: what they
are
on pa
g
e 26
)
.
English
- 16 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
5. Once all parameters are set, to exit and to go back to the programming menu, press
for a short time the key .
To exit and to go back to the normal operation (automatic, manual) press for a long
time the key or wait for the time-out expiration (40 seconds about).
If a timing is active, the display shows the symbol .
To interrupt a timing, access again the menu and set the value .
Advanced functions menu
With the ADV menu it’s possible to modify the
following operation parameters:
- operating mode (heating or cooling)
- regulation type (on-off or proportional)
- parameters relative to regulation type
- antifreeze temperature
- password for key lock
- system operation hours.
To access the menu ADV:
1. From the normal operation display, press for a long time the key until the
symbol starts flashing on field (2).
2. Press for a short time the key until the symbol starts flashing and press the
key to access the parameters modification.
3. At this point the first parameter of the menu starts flashing:
press the keys and to modify the parameter and the key to confirm and
to move to the next parameter.
To exit the parameters modification press the key .
English
- 17 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Operating mode
This parameter allows to specify the operating mode of the chronothermostat, between
winter-heating ( ) and summer-cooling ( ).
For further information about the operating mode see the chapter “Regulation
types” on page 24.
Regulation type (only for heating mode)
For heating mode it’s possible to choose between on/off regulation (5HJ) or
proportional (U(J3) or proportional programming (UHJW3) to use if the remote
actuator is a valve for ThermoPro RF radiators).
For further information about regulation type see the chapter “Regulation
types” on page 24.
English
- 18 -
CHRONOS RF Radiofrequency digital chronothermostat User Manual
Regulation parameters
In case of on/ off regulation the only parameter to set is the hysteresis (G,)), which
can have values between 0.1 °C e 1 °C.
In case of proportional regulation the parameters to set are the regulation band (EQG) e
il periodo di regolazione (3(U).
For further information about how to choose these values see the chapter
“Regulation types” on page 24.
But remember that the preset settings are suitable for the most part of the
situations: to change these settings only if it’s really necessary.
Antifreeze temperature (only for heating mode)
For the heating mode it’s possible to set a safety
temperature (antifreeze temperature – II) to
maintain also if the chronothermostat is
switched off.
It’s possible to choose a value between 1 °C
and 50 °C. It’s also possible to deactivate the
antifreeze function pressing the key until
the display shows B. In this case, if the
chronothermostat is switched off, no safety
temperature is maintained.
Password for key lock
It’s possible to set a key lock if the
chronothermostat is installed in public places
or however if you want to prevent anyone from
modifying the operation parameters.
To set a password, enter on field 3$V a value
between 001 and 999. To deactivate the password
press the key until __ _ appears.
When the keyboard is locked, the thermostat performs all its functions using the set
regulation parameters.
For
f
urther in
f
ormation about how to choose these values see the chapter
“R
egu
l
at
i
on types
on page 24
.
But remember that the preset settings are suitable
or the most part o
the
s
ituations: to change these settings only i
f
it’s really necessary
.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Vemer Chronos RF Bianco User manual

Category
Thermostats
Type
User manual

Vemer Chronos RF Bianco is a radiofrequency digital chronothermostat that allows you to regulate the ambient temperature both in heating and cooling modes. It can be controlled via a remote actuator through a radiofrequency signal, allowing you to manage your heating and cooling system wirelessly. The wide touch screen display with backlighting allows for clear viewing even in the dark. The chronothermostat has a weekly programming feature with 3 different settable temperatures, so you can customize your heating and cooling schedule to suit your needs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI