Instruction CF-RF Room Thermostat with Infrared Floor Sensor
Floor surface temperature limitation
1. Ensure actual floor surface temperature is
shown in the display illustrated by
2. Press and hold the push button until SET
MAX is also shown in the display
3. Press the up/down selector to set the
maximum floor surface temperature limitation
4. Press the push button shortly, SET MIN is
also shown in the display
5. Press the up/down selector to set the mini-
mum floor surface temperature limitation
IMPORTANT!
As heat emission from the floor may vary slightly
depending on floor covering - and thereby cause
inaccurate temperature measurement - it may be
necessary to adjust the setting of max. and min.
floor surface temperatures accordingly.
! It is important always to follow recommendations
from the floor manufacturer regarding max. floor
surface temperature.
! It is recommended always to include mixing shunt
for floor heating circuits in order to ensure optimal
flow temperature. - In addition to minimised energy
consumption, correct setting of the flow tempera-
ture will eliminate the risk of excessive heat transfer
to the floor.