SAFETY & WARNING INSTRUCTIONS
MAINTENANCE
15. Before each use, thoroughly
inspect your unit for loose or
damaged parts. Do NOT use until
adjustments or repairs have been
made.
16. All attachments must be installed
properly before operating the unit,
such as debris collector bag.
17. Keep all bystanders especially pets
and children at least fifty (50) feet
from the unit while using.
18. To avoid unintentionally starting of
the unit, do NOT carry plugged-in
unit with your finger on the switch.
Be sure the unit is unplugged.
19. Always remain alert and use
common sense when using this
unit. To prevent injury to yourself
and to others, NEVER use the
leaf blower when your are tired.
20. DO NOT operate this unit while
under the influence of drugs,
alcohol or medication.
21. Do NOT over reach or use the leaf
blower from unstable surfaces such
as ladders, trees, steep slopes,
rooftops, etc. Keep proper footing and
balance at all times.
22. Wear heavy, long pants, boots,
gloves and a long sleeve shirt. Do
NOT wear loose clothing, jewelry,
short pants sandals or go barefoot.
Secure hair above shoulder level.
23. Always turn switch off when
vacuuming or blowing is delayed or
when changing locations. Always
inspect new locations before
operating.
24. To reduce the risk of electrical
shock, use only with an extension
cord intended for outdoor use such as
SW-A, SOW-A, STW-A, STOW-A,
SJW-A, SJOW-A, SJTW-A or
SJTOW-A.0
25. Ground Fault Circuit Interrupter
(GFCI) protection should always be
provided on electrical circuits or
outlets to be used for this unit.
26. To reduce the risk of electrical shock,
use only with a two conductor
extension cord intended for outdoor
use.
27. Never connect the unit to an AC
voltage that differs from the one on
the unit’s rating plate.
28. To reduce the risk of electrical shock,
this unit has a polarized plug (one
blade is wider than the other) and will
require the use of a polarized
extension cord. This unit plug will fit
into a polarized extension cord only
one way. If the plug does not fit,
obtain a correct polarized extension
cord. A polarized extension cord
requires the use of a polarized wall
outlet. This plug will fit into a polarized
wall outlet only one way. If the plug
does not fit, contact a qualified
electrician to install the proper
wall outlet. Do NOT change the unit
plug, extension cord receptacle or
extension cord plug in any way.
29. When using an extension cord, make
sure that it is a cord that is heavy
enough to carry the current that your
unit will draw. An undersized
extension cord will cause a drop is
line voltage resulting in loss of power
and overheating. The table below
shows the correct size to use
depending on the cord length and
amperage rating.
Removing Debris from Clogged
Impeller
4. Air dry for 24hrs.
5. Do Not install onto unit until bag is
completely dry.
6. To clean tubes, remove from unit first,
then use a hose to clear grass or
leaves stuck inside of tubes.
1. Turn off and unplug the vacuum from
the power source and wait for all
moving parts to stop.
2. Remove the easy grip handle, or the
inlet cover.
3. Remove blockage. If necessary dislodge
blockage with a wooden stick.
4. Check the impeller for any signs of
damage. If damage to any parts have
occurred contact customer service at
1 (800) 275-9251.
5. Install the vacuum tube or, if you want to
switch to blower mode see instructions
for correct procedure.
WARNING: Never douse or squirt
motor with water or any other liquid.
Keep handles and tubes dry, clean and
free from debris.
Storage of Leaf Blower
1. Store unit and extension cord in a
indoors.
2. Keep out of reach of children.
3. Tubes can be stored upright after
assembly, however ensure that
there are no sharp objects that can
damage tubes.
4. Do not store tubes under any other
items. This can cause permanent
dents in the tubes.
Cleaning Bag and Tubes
Best performance is achieved with proper
cleaning and maintenance.
1. Unplug unit from power source, and
ensure all parts have stopped moving.
2. Empty bag according to instructions on
page 10.
3. To clean bag, turn inside out and
hose down the bag.
WARNING
TROUBLESHOOTING
To reduce the risk of electrocution,
keep all connections dry and off the
ground. Do not touch the plug with wet
hands.
2
Extension Cord Length
25' 50’ 100’ 150’
AMPERAGE
RATING
WIRE SIZE (AWG)
1-10 AMPS 18 16 14 12
30. Keep impeller clean of vegetation
and other foreign materials.
Cooling air inlets may become
clogged with debris. Overheating
the unit can increase risk of fire or
injury.
31. When using the unit, always hold
the unit with both hands. Keep a
firm grip on the front handle and
on the top handle.
1. Unplug and clear unit of debris.
2. Contact FANTOM Customer
Service at 1 (800) 275-9251.
1. Debris in air intake
area.
2. Mechanical failure.
Impeller will not turn
freely
1. Contact FANTOM Customer
Service at 1 (800) 275-9251.
2. Inspect unit for blockage.
1. Mechanical failure.
2. Blockage to parts.
Unit vibrates
abnormally
1. Move switch to ON position.
2. Reconnect extension cord.
3. Reset circuit breaker or fuse.
4. Contact FANTOM Customer
Service at 1 (800) 275-9251.
1. Switch in the OFF
position.
2. Extension cord
disconnected
3. Circuit breaker
tripped, or fuse blown.
4. Mechanical failure.
Unit fails to operate
REMEDYCAUSESYMPTOM
TROUBLESHOOTING GUIDE
11